Laserfiche WebLink
<br />January 21, 2000 <br /> <br />T-BRACE DETAIL <br /> <br />ST - T- BRACE <br /> <br />fVlDO @ <br /> <br /> <br />, ,== <br />, ,== <br /> <br />W UlD <br /> <br />T-Brace size <br />1 x4 or 6 <br />2x4,6,orB <br /> <br />Nailing Pattern <br />Nail Size <br />1Qd <br />16d <br /> <br />Nail Spacing <br />8nQ.c. <br />B"o.c. <br /> <br />Note: Nail along entire length of T-Brace <br />(On Two-Ply's Nail to Both Plies) <br /> <br /> <br />SPACING <br /> <br />WEB <br /> <br />T-BRACE <br /> <br />Nails <br /> <br />~ / Section Detail <br /> <br /> <br />~ - T-Rrace <br /> <br /> <br />~ Web <br /> <br />MiTek Industries, Inc. Chesterfield, MO <br /> <br />Note: T-Bracing to be used when continuous <br />lateral bracing is impractical. T-brace <br />must cover 90% of web length. <br /> <br />T-Brace Size <br />for One-Ply Truss <br />Specified Continuous <br />Rows of Lateral Bracing <br />Web Size 2 <br />2x3 or 2x4 1 x4 *** <br />2x6 1 x6 *** <br />2x8 2x8 *** <br />*** DIRECT SUBSTITUTION NOT APPLICABLE. <br /> <br />T-Brace Size <br />for Two-Ply Truss <br /> <br />Specified Continuous <br />Rows of Lateral Bracing <br /> <br />Web Size 1 2 <br /> <br />---2xB--or-2x4---- "-2x4--- *""-- <br /> <br />2x6 2x6 <br /> <br />2x8 2x8 <br /> <br />*** DIRECT SUBSTITUTION NOT APPLICABLE. <br /> <br />T-Brace must be same species grade (or better) as web member. <br />