<br />FORM 600A-2004R <br /> <br />EnergyGauge@ 4.5.2 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: , , , <br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION --~. REQUIREMENTS FOR EACH PRACTICE --.._---~-~ -- CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq,ft. window area; .5 cfm/sq,ft, door area. <br />Exterior & Adjacent Walls 606,1.ABC.1,2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the top plate. <br />Floors 606,1.ABC,1.2.2 Penetrations/openings >H8" sealed unless backed by truss or joint members, <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams, <br />Ceilings 606.1.ABC.1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter, at penetrations and seams, <br />Recessed Lighting Fixtures 606.1.ABC,1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />-- conditioned space, tested. --------- - <br />Multi-story Houses 606.1.ABC,1,2,5 _ ,Air barrier on perimet~r of floor cavity between floors, <br />Additional Infiltration reqts !606,1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />- <br />Water Heaters 612.1 Comply with efficiency requirements in Table 612,1,ABC.3.2. Switch or clearly marked cir <br /> breaker (electric) or cutoff (aas) must be provided. External or built-in heat trap reauired. <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer, Gas spa & pool heaters must have a minimum thermal <br /> efficiencv of 78%, <br />Shower heads 612,1 Water flow must be restricted to no more than 2.5 Gallons per minute at 80 PSIG, <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607,1 Separate readilv accessible manual or automatic thermostat for each system. <br />Insulation 604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides, <br /> I Common ceiling & floors R-11, <br /> i <br /> <br />EnergyGauge 1M DCA Form 600A-2004R <br /> <br />EnergyGauge@lFlaRES'2004R FLRCSB v4,5,2 <br />