<br />Residential Whole Building Performance Method A - Details
<br />
<br />I ADDRESS: , , ,
<br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />PERMIT #:
<br />
<br />COMPONENTS SECTION --~. REQUIREMENTS FOR EACH PRACTICE --.._---~-~ -- CHECK
<br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq,ft. window area; .5 cfm/sq,ft, door area.
<br />Exterior & Adjacent Walls 606,1.ABC.1,2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & top/bottom plates; between walls and floor.
<br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> from, and is sealed to, the foundation to the top plate.
<br />Floors 606,1.ABC,1.2.2 Penetrations/openings >H8" sealed unless backed by truss or joint members,
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br /> to the perimeter, penetrations and seams,
<br />Ceilings 606.1.ABC.1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> installed that is sealed at the perimeter, at penetrations and seams,
<br />Recessed Lighting Fixtures 606.1.ABC,1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
<br />-- conditioned space, tested. --------- -
<br />Multi-story Houses 606.1.ABC,1,2,5 _ ,Air barrier on perimet~r of floor cavity between floors,
<br />Additional Infiltration reqts !606,1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br /> have combustion air.
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
<br />
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />-
<br />Water Heaters 612.1 Comply with efficiency requirements in Table 612,1,ABC.3.2. Switch or clearly marked cir
<br /> breaker (electric) or cutoff (aas) must be provided. External or built-in heat trap reauired.
<br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools
<br /> must have a pump timer, Gas spa & pool heaters must have a minimum thermal
<br /> efficiencv of 78%,
<br />Shower heads 612,1 Water flow must be restricted to no more than 2.5 Gallons per minute at 80 PSIG,
<br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
<br /> Ducts in unconditioned attics: R-6 min. insulation.
<br />HVAC Controls 607,1 Separate readilv accessible manual or automatic thermostat for each system.
<br />Insulation 604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides,
<br /> I Common ceiling & floors R-11,