<br />Code Compliance Checklist-
<br />Residential Whole Building Performance Method A - Details
<br />
<br />I ADDRESS: , · ,
<br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />PERMIT #:
<br />
<br /> ,
<br />COMPONENTS SECTION ,.-- ~q~!R!MENTS FQR EACH PRACTICE ,"-' ---.' CHECK'
<br /> ..
<br />Exterior WlndOWll & P.90rs 6~..1 ,ABC.1.1 .. Maximum;.~ efmISCl.f!:.w!ndow area;.,q cfm/sQ.ft., door area. .. ..- .., ~_....
<br />Extenor & Adjacent Walls 608.1.ABC.1.2.1 Caulk, galket, weatherstrip or seal between: windows/door. & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & top/bottom plates; between wells and floor.
<br /> EXCEPTION: Frame walls where a continuous Infiltration barrier is installed that extends
<br />--. .- , .- , . . Jrom, and is.s~aled to, lh~ roundallon to t~~ toP plate..:, ~. "
<br />Floors 606.1.ABC.1,2.2 Penetrations/openings >118" sealed unless bael<ed by truss or Joint members.
<br /> EXCEPTION: Frame floor. where a continuous inliltratlon barrier II installed that is sealed
<br />-- .. " ' tg the Derlmel!t~1 I)tnetratio~ _and leams. . , -' . *"'..-....
<br />Ceilings 608, , .ABC.1.2.3 Between walls & ceilings; penetrations of eeiling plane of top floor. around shafts, chase..
<br /> sofftt8. chimneys, eablnets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access. EXCEPTION: Frame oeilings where a continuous Infiltration barrier is
<br />~. - .. .-- ~~lIed that is s~!ed at the perrmeter. at pen~!rations and leams. ..-....
<br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penettaUons, sealed; or Type IC or non-Ie rated, Installed Inside a
<br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
<br />" ..- . ." condilio~d sDace, test!<l. .... ..
<br />~.~orv 1ol0u88S .,' 606,1.A8C.1.2.5 .' Air barrier 0.1) perimeter of .f1,por cavity b~tween floors., . .
<br />AddItional Infiltration reqts 606.1.ABC.1.3 Exhaust fans venteclto outdoors. dampers; combustion space heaters comply with NFPA,
<br /> have combustion air.
<br />
<br />6A.22 OTHER PRI!SCRIPTIVE MEASURES (must be met or exceeded by all r.sldences.)
<br />
<br /> "
<br />COMPONE.m-s SECTlQt' I\EQUIREME~T~ ---.. .. 'CHEC'K:
<br />Water Healers 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked e1r
<br /> breaker l~j~r1c) or cutoff (gas) ml!l!t be p!ovlded~extemal or buil!,:ln heat tr~12 reauired. , .. ,
<br />f---- -- -..--..
<br />Swimming Pools & Spas 612.1 Spas & heated pools must have cov.rs (except solar healed). Non-commercial poolS
<br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br />- efficiency of 78%. -_.1' n.a ..' ". ..
<br />~~r heads ...,..- 612.1 Water flow must be res..tricted to no '!!C?" than 2.5 lIallons Der minute at 80 PSIG. .,-
<br />AIr Distnbution Systems 610.1 All dUets. fittings, mechanical equipment and plenum chambers shall be mechanically
<br /> attached, Haled, insulated, and installed in accordance with the criteria Of Section 610.
<br />- .. ,. Ducts in uncondilio.n8!l attles: ~-6 ~in. insulation.:. -'-- --.-
<br />JiY.~C Controls - . 607.1 SeDarale readilY aecessi,ble manual or a!ltomatlc thermostat for.e,Jch 5ysten'h ~
<br />Insulation 504.1, 602,1 Ceiting$-Mln. R.19. Common walls-Frame R.11 or CBS R-3 both sides.
<br /> Common t;ltiling & floors R-1'.
<br /> " ,
<br />
<br />EnergyGaugeTt04 DCA Form 600A-2004R