<br />MILLENNIUM METALS
<br />
<br />PAGE 02/02
<br />
<br />. Mtn '. ~(d~
<br />5V CR~MP & ~/ULLE:'NNIUM-V INSTAllATION GUIDE
<br />
<br />~_..b:..~~_'-"'." ..&. ___ _~.. J lll. .1III.-"11l1KrMII.__,,~,.___~, b. --.,a n~- _,....~"'_ ___~
<br />
<br />I BATT!;N ATTACHMENT Ii,' 31DE LA~ ~ETAIL ~I C' .MANUFACTU"-~~~~~I!,G RECOMMENDATIONS
<br />
<br />,____n 1"- PREVAILING,
<br />i i ! 16" I WIND I /;/?- ,qq-- __m ------..,-
<br />~ STARTER ,". FASTENER ' .>?
<br />~ EAV"REA. E~. _ .;:1/
<br />
<br />1- :'^:~~:'R SJ'f;.'~~ ~"~~~~~rON /f_~,/:_:',',','_",/,:
<br />
<br />#9 NAIL 8" OC i - ---. m__ ,
<br />'.~ D!ET~IIl.. A _.._ - DETAIL IB-~ _,. ~ETA.L C & D
<br />
<br />~t,~; Make sure the deck is level and square, Batten strips are optional in new construction and reroofIng over shingles. Roof deckIng
<br />integrity should be checked \0 Insure adequate pull out in any reroQfing application. Shingles can not be battened over it more than two
<br />!@yers of shingles are present. Apply batten strips according to Detail A, Banens are to be 1 x 3 yellow pine according to ASCE 793
<br />Standard. Millennium recommends 30# felt to be applied as a condensation baniar Attachment of felt shall be in compliance with building
<br />codes for area, An additional layer of #15 felt must be used as separation sheet if attachment of felt paper is to be done with Un tab.
<br />
<br />~~e.P.2.;. install Eave Drips and valley according 10 details. 'rrim should be fastened 12" OC or sn on center depending on .lone location,
<br />Remember to use inside c10slJre strips between Eave and Panel to eliminate water InHltration.
<br />
<br />Stgp_~ I;)anel placement should begin on the gable end opposite of the prevailing wind. Slarter edge of the panel will be the lap edge.
<br />{Opposit'l1l of ami-sip/lon edge}. After laying first panel ohecK for squareness. Panel 2 should be lapped over anti-siphon groove of Panel 1.
<br />($t\lE) DeIall 6). A minimum of 1" overhang is required at eave, Alternative method of panel placement may begin ill the center of the roof.
<br />This mettlod involves centering the center point of the panel and working out to the gable or Iilxterior (;loges. Often this method is used when
<br />'the area covered Is not divisible by 2' or traditional placement allows for a pipe Hashing to CH;cur in a side lap, Endlaps must be a minimum
<br />of 12" and two strips of Butyl Sealarrt is recommend&d 8" on uphill side of lap to keep watertight.
<br />
<br />Step 4: Fasten pan~1 according to Detail Cor D depending on the area of application. Note that ASCE-798 requires additional screws in the
<br />flal area of the pan at all Ridge. Eave::; and Endlap areas. Millennium Metals recommends a #9 x 1-1/2 Wood Fastener. (Ultimate or Zacs
<br />are recommended on all warranteed jobs or coastal applications). Field attachment should be 16" on center. Trim F;;Istening should be
<br />increased 10 6" on center in high wind areas.
<br />
<br />1.,
<br />
<br />_ ~l.
<br />
<br />...- OETAll C
<br />" '~';'~~ FIELD ATTACHMENT
<br />\\\. 16 . ON CENTER
<br />\\;,~\
<br />0~'" DETAIL D
<br />\ '>~ (8IDGE. EAVES
<br />\,\'\ (l. END lAPS)
<br />\\~\ /
<br />\\ '~'~,l' f
<br />\. ~~~\
<br />\ ::;,>
<br />,._.__..__,u..__~" ::,~.,
<br />
<br />NOTE: Fastening in the 'flat of the panel is recogni7.ed as an alternative method of attachment and is acceptable in all areas which do not
<br />require PA-125 beHer known as Dade County testing.
<br />
<br />~te"p' 5: Any field cutting must be done with metal nibblers, metal snips, or blades designed lor metal cutting. No culting Should be done on
<br />roof, as It will cause iron shavings to be spread and adhere to roof panels_ Proper cutting should be dona exposed panel side down and field
<br />swept to remove Iron debris.
<br />
<br />~p_l;i..;. Install remaining accessories suCfJ as pipe boots. 5-V profile vent, ridge caps, and gable flashing. Butyl sealant and caulking are
<br />necessary to maintain watertight se!als. Also inspect screw fasteners to insure that they are installed properly (See Detail G),
<br />
<br />StelLl; Field clli!an the root surface with a broom to be sure any iron shavings are removed,
<br />
<br />PITCH STRUCTURAL ALERTI5V REQUIRES 3/12 PITCH TO MAINTAIN WATER DRAINAGE. THlS PANEL MUST BE INSTALLED OVER
<br />SOLID DECI\ING AS IT IS NON STRUCTURAL APPROVED DECK SUBSTRATES INCLUDE 5/8" PLYWOOD OR OSI3 BOARD. FIRE
<br />BARRIERS SUCH AS DENSDECf( AND ROCKTEC MAY ALSO BE REQUIRED FOR CERTAIN PROJECTS,
<br />
<br />ATTENTION !NSTAll_ER!! WHEN USING FASTENERS TO PENETRATE STEEL SHEETS THE IRON PARTICLES TEND TO GO AIRBORNE
<br />AND SETTLE 01\1 THE SHEET, IT IS NECESSARY TO REMOVE THESE PARTICLES TO PREVENT EMBEDMENT AND RUSr MARKS.
<br />
<br />Ill)
<br />,~:.........
<br />
<br />fIll
<br />1~~
<br />
<br />I~
<br />~'""'---
<br />
<br />[,..,-.--
<br />I
<br />I
<br />I
<br />I
<br />
<br />FASTEf\.!ERS #9 X 1-!/~ WOOD TYPE
<br />~""R__ .....<_._....,..._
<br />CORI=lF.:CT TOO LOOSE TOO TIGHT
<br />
<br />HIGH WIND CONSIDERATION
<br />
<br />F-[J~M MATr-:q'Al
<br />VISIBLE ,\T
<br />IN^$.'~H
<br />r-A3TnIEn IS
<br />"lltl!'~Ftr'{
<br />tr~ST^lLH1.
<br />
<br />EorM NOT AT
<br />vlSlfll.~ JOINT I
<br />NOT E'IOUGI"
<br />COM~AI:SSION I
<br />TO MAKF. A SIO^,- .
<br />
<br />-, I
<br />
<br />WPM If;
<br />PAN"'ED AND IS
<br />PR01'R'-,'>INC.,
<br />ElF.YOND EDGE
<br />OF f^~rr=I\IHi.
<br />
<br />Millennium Metals has achieved PA 125 testing better known as Dade
<br />County on 5V Crimp. This test includes UL 580 Class 90 testing. The testing
<br />installation was done on 5/8" plywood with a fire barrier. The plywood was
<br />attached by a #9 nail /6" on center and 4" on perimeter area. 26 gauge 5V
<br />Crimp panels were attached 12" on center with a # 9" )( 1-1 /2 Fastener anI
<br />6" on the perimeter. Please request a copy of PA 125 Installat ion instructionj
<br />if required for your area.
<br />
<br />
<br />~.... ". ...--.-.----.-- ..-.... .-- ---_._~.. ..........
<br />
<br />IDlET.A~L G
<br />
<br />MILLENNIUM METALS INC_ 10200 EASTPORT RD. JACKSONVILLE, FL 32218
<br />
|