<br />. "tqeD / Fire & Building
<br />/ Products
<br />
<br />Technical SeNices: Tel: (800) 381-9312/ Fax: (800) 791-5500
<br />www.tyco-fire.com
<br />
<br />Grinnell Grooved Fire Protection Products
<br />Grooved Fittings
<br />
<br />General
<br />Description
<br />
<br />rfiY'D) ~ See Fire Protection
<br />~ VdS Submittal Sheet for
<br />Pressure Rating and
<br />fU:\ ili.r\C Listing/Approval
<br />\:!.Y~~ Information
<br />
<br />~
<br />
<br />The grooved fittings provide an economical
<br />and efficient method of changing direction.
<br />adding an outlet. reducing, or capping
<br />grooved piping systems. Grooved fittings
<br />are available in durable ductile iron or
<br />fabricated steel as indicated.
<br />Note: Figure 5108 and 5198 fittings are
<br />special short radius fittings with smaller
<br />center to end dimensions than standard
<br />grooved fittings, Depending on the size and
<br />coupling used, there may be interferences at
<br />the bolt pads that require repositioning of the
<br />coupling orientation. The use of flange
<br />adapters is not recommended with Figures
<br />5108 and 5198 fittings, Contact Tyco Fire
<br />Products for details.
<br />WARNING
<br />The Fittings described herein must be installed
<br />and maintained in compliance with this document,
<br />as well as with the applicable standards of the
<br />National Fire Protection Association, in addition
<br />to the standards of any other authorities having
<br />jurisdiction, Failure to do so may impair the
<br />performance of this device.
<br />The owner is responsible for maintaining their
<br />fire protection system and devices in proper
<br />operating condition. The installing contractor or
<br />sprinkler manufacturer should be contacted with
<br />any questions,
<br />
<br />Technical
<br />Data
<br />
<br />Approvals:
<br />UL, FM, ULC, VdS, and LPCB;
<br />Note: See Fire Protection Submittal Sheet for
<br />exact Listing / Approval information,
<br />
<br />Page 1 of 6
<br />
<br />Material:
<br />Cast Figures: 201,210.219.250,260,501,510,
<br />519, 51 ODE, 501S, 510S and 519S-
<br />Ductile iron conforming to ASTM A-536,
<br />Grade 65-45-12
<br />Fabricated Steel: Figures 391, 392, 393, 312,
<br />313,321,327,341 and 350 - Carbon Steel,
<br />(Sizes 1 W - 6" are Schedule 40);
<br />(Sizes 8" - 12" are Schedule 30),
<br />conforming to ASTM A-53 Grade B
<br />Protective Coatings:
<br />. Non-lead orange paint
<br />. Fire brigade red (optional) non-lead paint
<br />· Hot dipped galvanized conforming to ASTM
<br />A-153
<br />
<br />Ordering
<br />
<br />Procedure
<br />
<br />When placing an order, indicate the full product
<br />name, Please specify the quantity, figure number,
<br />wall thickness, and size.
<br />Grinnell Grooved Piping Products, valves,
<br />accessories and other products are available
<br />throughoutthe U,S" Canada. and internationally,
<br />through a network of distribution centers. You
<br />may write directly or call 215-362-0700 for the
<br />distributor nearest you.
<br />
<br />Care and
<br />Maintenance
<br />
<br />The owner is responsible for the inspection,
<br />testing, and maintenance of their fire protection
<br />system and devices in accordance with the
<br />applicable standards ofthe National Fire Protection
<br />Association (e,g., NFPA 25), in addition to the
<br />standards of any authority having jurisdiction,
<br />The installing contractor or product manufacturer
<br />should be contacted relative to any questions.
<br />Any impairment must be immediately corrected.
<br />It is recommended that automatic sprinkler
<br />systems be inspected, tested, and maintained by
<br />a qualified Inspection Service.
<br />
<br />September 2004
<br />
<br />Limited
<br />
<br />Warranty
<br />
<br />Products manufactured by Tyco Rre Products are
<br />warranted solely to the original Buyer for ten (10)
<br />years against defects in material and workmanship
<br />when paid for and properly installed and maintained
<br />under normal use and service. This warranty will
<br />expire ten (10) years from date of shipment by Tyco
<br />Fire Products. No warranty is given for products or
<br />components manufactured by companies not
<br />affiliated by ownership with T yco Fire Products orfor
<br />products and components which have been subject
<br />to misuse, improper installation. corrosion, orwhich
<br />have not been installed. maintained, modified or
<br />repaired in accordance with applicable Standards of
<br />the National Rre Protection Association (NFPA).
<br />and/orthe standards of any other Authorities Having
<br />Jurisdiction. Materials found by Tyco Rre Products
<br />to be defective shall be either repaired or replaced, at
<br />Tyco Rre Products' sole option. Tyco Fire Products
<br />neither assumes, nor authorizes any person to
<br />assume for it, any other obligation in connection with
<br />the sale of products or parts of products. T yco Fire
<br />Products shall notbe responsible forsprinkJersystem
<br />design errors orinaccurateorincompleteinformation
<br />supplied by Buyer or Buyer's representatives.
<br />IN NO EVENT SHALL 1YCO FIRE PRODUCTS BE
<br />LIABLE, IN CONTRACT, TORT. STRICT L1ABILl1Y
<br />OR UNDER ANY OTHER LEGAL THEORY, FOR
<br />INCIDENTAL, INDIRECT, SPECIAL OR
<br />CONSEQUENTIAL DAMAG ES, INCLUDING BUT NOT
<br />LIMITED TO LABOR CHARGES, REGARDLESS OF
<br />WHETHER1YCO RREPRODUCTSWftS INFORMED
<br />ABOUT THE POSSIBILl1Y OF SUCH DAMAGES,
<br />AND IN NO EVENT SHALL 1YCO FIRE PRODUCTS'
<br />L1ABILl1Y EXCEED AN AMOUNT EQUAL TO THE
<br />SALES PRICE.
<br />THE FOREGOING WARRANTY IS MADE IN LIEU OF
<br />ANY AND ALL OTHER WARRANTIES EXPRESS OR
<br />IMPLIED, INCLUDING WARRANTIES OF
<br />MERCHANTABILITY AND FITNESS FOR A
<br />PARTICULAR PURPOSE.