Laserfiche WebLink
<br />Page 2 of 2 <br /> <br />assumes, nor authorizes any person to <br />assume for it, any other obligation in <br />connection with the sale of products or <br />parts of products. Tyco Fire & Building <br />Products shall not be responsible for <br />sprinkler system design errors or inac- <br />curate or incomplete information sup- <br />plied by Buyer or Buyer's repre- <br />sentatives. <br /> <br />IN NO EVENT SHALL TYCO FIRE & <br />BUILDING PRODUCTS BE LIABLE, <br /> <br />Figure 577 <br />Grooved <br />Coupling <br /> <br />IN CONTRACT, TORT, STRICT LI- <br />ABILITY OR UNDER ANY OTHER LE- <br />GAL THEORY, FOR INCIDENTAL, <br />INDIRECT, SPECIAL OR CONSE- <br />QUENTIAL DAMAGES, INCLUDING <br />BUT NOT LIMITED TO LABOR <br />CHARGES, REGARDLESS OF <br />WHETHER TYCO FIRE & BUILDING <br />PRODUCTS WAS INFORMED <br />ABOUT THE POSSIBILITY OF SUCH <br />DAMAGES, AND IN NO EVENT <br /> <br /> <br />-lcl <br /> <br />TFP1854 <br /> <br />SHALL TYCO FIRE & BUILDINC? <br />PRODUCTS' LIABILITY EXCEED AN <br />AMOUNT EQUAL TO THE SALES <br />PRICE. <br /> <br />THE FOREGOING WARRANTY IS <br />MADE IN LIEU OF ANY AND ALL <br />OTHER WARRANTIES EXPRESS <br />OR IMPLIED, INCLUDING WARRAN- <br />TIES OF MERCHANTABILITY AND <br />FITNESS FOR A PARTICULAR PUR- <br />EQSE.. <br /> <br />Pipe Max! + Max. t Max, t Nominal Dimensions Bolt Net <br /> 0.0, End Gap Pressure End Load A B C Size" Weight <br />Size Inches Inches psi Lbs. Inches Inches Inches Dia, x Lg, Lbs. <br /> mm mm kPa N mm mm mm Kg <br />1 1/4" 1.660 0.06 300 649 2.68 4.21 1.65 3/8" x 2 1/4" 1.3 <br />42.4 1.5 2,068 2,888 68 107 42 M10x57 0.6 <br />1 1/2" 1. 900 0,06 300 851 2.91 4,45 1.65 3/8" x 2 1/4" 1.5 <br />48.3 1.5 2,068 3,783 74 113 42 M10 x 57 0.7 <br />2" 2.375 0.06 300 1329 3,39 5,00 1.69 3/8" x 2 1/4" 1.8 <br />60.3 1,5 2,068 5,912 86 127 43 M10x57 0.8 <br />21/2" 2.875 0.06 300 1947 3,90 5.43 1,77 3/8" x 21/4" 2.0 <br />73,0 1.5 2,068 8,663 99 138 45 M10 x 57 0.9 <br />76.1 mm 3.000 0.06 300 2121 3.98 5,59 1.77 3/8" x 21/4" 2,0 <br />76.1 1.5 2,068 9,433 101 142 45 M10 x 57 0.9 <br />3" 3.500 0.06 300 2886 4.49 6,14 1,77 3/8" x 2 1/4" 3.3 <br />88,9 1.5 2,068 12,839 114 156 45 M10x57 1,5 <br />4" 4.500 0.19 300 4771 5,71 7.52 1.85 3/8" x 2 1/4" 3.3 <br />114.3 4,8 2,068 21,223 145 191 47 M10x57 1.5 <br />139,7 mm 5,500 0,19 300 7127 6.81 8,74 1,93 1/2" x 3" 5,3 <br />139.7 4.8 2,068 31,704 173 222 49 M12 x 76 2.4 <br />5" 5.563 0.19 300 7291 6,85 8,82 1.93 1/2" x 3" 5.3 <br />141.3 4,8 2,068 32,434 174 224 49 M12 x 76 2.4 <br />165,1 mm 6,500 0,19 300 9955 7.80 9,76 1.93 1/2" x 3" 5,7 <br />165.1 4,8 2,068 44,280 198 248 49 M12 x 76 2.6 <br />6" 6,625 0,19 300 10341 7.91 9.88 1.93 1/2" x 3" 5.9 <br />168.3 4,8 2,068 46,000 201 251 49 M12 x 76 2.7 <br />8" 8,625 0.19 300 17527 10.24 12.80 2.40 5/8" x 3 1/4" 11,7 <br />219,1 4,8 2,068 77,966 260 325 61 M16x83 5.3 <br /> <br /> <br />. Maximum available gap between pipe ends. Minimum gap = 0, <br /> <br />t Maximum pressure and end load are total from all loads based on standard weight steel pipe. <br />Pressure ratings and end loads may differ on other pipe materials and/or wall thickness, Contact <br />Tyco Fire & Building Products for details. See Fire Protection Equipment Submittal Sheet for Listing <br />and Approval pressure ratings. <br /> <br />.. Gold color coded metric bolt sizes are available upon request. <br /> <br />+ Max, End Gap is for cut grooved standard weight pipe, Valves for roll grooved pipe will be 1/2 that <br />of cut grooved, <br /> <br />Figure 577 Rigid Couplings have an Anti-Rotation Feature of "gripping teeth" along the coupling keys. which make the Figure 577 perfectly <br />suited for "arm over" installations where the likelihood of rotation is greatest. This feature may eliminate the need of extra hangers to <br />support the arm over due to increased rigidity and gripping force saving time and cost. <br /> <br />General Notes: It is the Designer's responsibility to select products suitable for the intended service and to <br />ensure that pressure ratings and performance data is not exceeded, Always read and understand the <br />installation instructions (IH-l000). Never remove any piping component or correct or modify any piping <br />deficiencies without first depressurizing and draining the system, Material and gasket selection should be <br />verified to be compatible for the specific application, <br /> <br /> <br />Certified Company <br /> <br />TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 <br />