Laserfiche WebLink
<br />Page 2 of 2 <br /> <br />TFP1880 <br /> <br />Figure 71 Flange Adapter <br />Gir <br /> <br />r'fF <br /> <br />BED <br /> <br />L~- <br /> <br />A <br /> <br /> <br /> <br />Figure 71 ANSI Calss 125 and 150 <br /> <br />Pipe Max t Max t Nominal Dimensions Bolts + Net <br />Nominal 0,0, Pressure End Load A B C *0 *E F WI. <br />Size Inches psi Lbs, Inches Inches Inches Inches Inches Inches Size Oty, Ibs. <br />Inches mm kPa N mm mm mm mm mm mm Oia. x Lg. kg <br /> 2.375 250 1,107 6.38 4,75 0,75 2,38 3.41 7.25 3.0 <br />2 60.3 1,724 4,924 162.1 120,7 19,1 60.5 86,6 184.2 5/e' X 3' 4 1.4 <br /> 2.875 250 1,622 7.00 5,50 0.88 2,88 3.91 7,88 5.0 <br />2'/2 73.0 1,724 7,215 178.0 140.0 22.0 73,0 99.0 200,0 5/e' X 3" 4 2.3 <br /> 3,500 250 2,404 7,50 6.00 0,94 3.50 4,53 9.88 5.6 <br />3 88.9 1,724 10,693 190.5 152.4 23.9 88.9 115.1 251.0 5/e' X 3" 4 2.5 <br /> 4,500 250 3,974 9.00 7,50 0,94 4,50 5,53 9.90 7.0 <br />4 114.3 1,724 17,676 228.6 190,5 23.9 114.3 140,5 251.5 5/8" x 3" 8 3.2 <br /> 5.563 250 6,073 10.00 8,50 1,00 5.56 6,72 11,38 9.2 <br />5 141.3 1,724 27,013 254,0 215.9 25.4 141.2 170.7 289,1 3/4' x 3'/2' 8 4.2 <br /> 6,625 250 8,614 11.00 9,50 1.00 6.62 7.78 11,88 10,0 <br />6 168.3 1,724 38,315 279.4 241.3 25.4 168,1 197.6 301.8 3/.' x 3'/2' 8 4.5 <br /> 8.625 250 14,599 13.50 11,75 1.13 8.62 9.94 14.38 16.6 <br />8 219,1 1,724 64,936 342.9 298.5 28.7 218,9 252,5 365.3 3/4" x 3'/2' 8 7.5 <br /> 10,750 250 22,679 16.00 14.25 1.19 10,75 12.31 16.88 21.8 <br />10 273.0 1,724 100,876 406.4 362.0 30.2 273.1 312.7 428,8 1/e' X 4' 12 9.9 <br /> 12.750 250 31,903 19,00 17.00 1.25 12.75 14,31 20.00 24.2 <br />12 323.9 1,724 141,905 482.6 431.8 31.8 323.9 363.5 508,0 1/e' X 4" 12 11.0 <br /> <br />Figure 71 PN16 <br /> <br />Pipe Maxt Maxt Nominal Dimensions Bolts + Net <br />Nom.Size Pressure End Load A B C *0 *E F WI. <br />Inches 0.0, Lbs. Inches Inches Inches Inches Inches Inches Size Oty. Ibs. <br />mm mm Bar N mm mm mm mm mm mm Dia. x Lg. kg <br />2" 1,028 6,38 4,92 0.75 2.38 3.41 7.25 3,0 <br />50 60,3 16 4,573 162,1 125.0 19.1 60.5 86.6 184.2 M16 x 76 4 1.4 <br />2'/2" 1,640 7,28 5.71 0,88 3,00 4.03 8,09 5,6 <br />65 76.1 16 7,295 184,9 145.0 22.4 76,1 102.4 205.5 M16 x 76 4 2,5 <br />3" 2,232 7,88 6.30 0,94 3,50 4,53 8,75 6.6 <br />80 88.9 16 9,928 200.2 160,0 23,9 88.9 115.1 222,3 M16 x 76 8 3.0 <br />4" 3,690 9,00 7,09 0,94 4,50 5,53 9,90 7.0 <br />100 114,3 16 16,413 228.6 180.1 23,9 114,3 140.5 251.5 M16 x 76 8 3.2 <br />5" 5,512 9.84 8,27 1.00 5,50 6,53 10.69 9,2 <br />125 139.7 16 24,517 249.9 210.1 25.4 139.7 165.9 271.5 M16 x 89 8 4.2 <br />6" 7,698 11,25 9.45 1.00 6.50 7.53 12.12 10.0 <br />150 165,1 16 34,241 285,8 240.0 25.4 165,1 191.3 307.8 M20 x 89 8 4.5 <br />6" 7,997 11.00 9.49 1.00 6.62 7.78 11.88 10,0 <br />150 168,3 16 35,571 279.4 241,1 25.4 168.1 197.6 301,8 M20 x 89 8 4.5 <br />8" 13,555 13.38 11,61 1,13 8.62 9.94 14.31 16,6 <br />200 219.1 16 60,293 339.9 294.9 28.7 218,9 252.5 363.5 M20 x 89 12 7.5 <br />10 21,057 16.00 13.98 1.19 10,75 12,31 16,88 21.8 <br />273.0 273,0 16 93,662 406.4 355.1 30,2 273.1 312.7 428.8 M22 x 102 12 9.9 <br />12' 29,621 18,12 16,14 1.25 12.75 14.31 19.19 28.0 <br />300 323.9 16 131,754 460.2 410.0 31.8 323.9 363,9 487.4 M24 x 102 12 12.7 <br /> <br />t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may <br />differ on other pipe materials and/or wall thickness, Contact Tyco Fire Products for details, See Fire Protection Equipment <br />Submittal Sheet for Listing and Approval pressure ratings, <br />* Dimensions D and E represent minimum and maximum sealing surfaces, <br />+ Bolts and Nuts are not supplied, Bolt lengths are standard; it is the responsibility of the purchaser to verify <br />correct length for the intended application, <br /> <br />General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure <br />that pressure ratings and performance data is not exceeded, Always read and understand the installation <br />instructions (IH-1 000), Never remove any piping component or correct or modify'any piping deficiencies without <br />first depressurizing and draining the system, Material and gasket selection should be verified to be compatible <br />for the specific application, <br /> <br /> <br />TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 <br /> <br />Certified Company <br />Printed U,SA <br />