Laserfiche WebLink
<br />TERMITE SPECIFICATIONS: <br /> <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br /> <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br /> <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE.(FBC 1816.1.1) <br /> <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED,(FBC 1816.1,2) <br /> <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS V1UST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOiL AFTER THE iNITIAL TREATMENT.(FBC 1816.1.3) <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT is <br />REQUIRED.(FBC 1816.1.4) <br /> <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT,(FBC 1816.1.5) <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRECOI'"STRUCTION TREATME:'-JT.(FBC 1816,1.7) <br /> <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE iSSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816.1.7) <br /> <br />14. AFTER ALL WORK is COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br /> <br />15. NO WOOD, VEGETATION, STUV1PS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br /> <br />A.B. <br />Abv. <br />A/C <br />Adj. <br />A.F.F. <br />A.H.U, <br />ALT. <br />B.C, <br />B,F. <br />Bk Sh <br />Bm. <br />BOT. <br />B.P. <br />Brg. <br />Cir. <br />Clg. <br />Col. <br />Camp. <br />C.T. <br />o <br />Dec. <br />Ded. <br />Obi. <br />Dia. <br />Disp. <br />Dist. <br />D.S. <br />D.V. <br />DW. <br />Ea. <br />EW. <br />Elec. <br />Elev, <br />Ext. <br />Exp. <br /> <br />ABBREVIATIONS <br /> <br />Anchor Bolt <br />Above <br />Air-Conditioner <br />Adjustable <br />Above Finished Floor <br />Air Handler Unit <br />Alternate <br />Base Cabinet <br />Blfold Door <br />Book Shelf <br />Beam <br />Bottom <br />Bypass door <br />Bearing <br />Circle <br />Ceiling <br />Column <br />A/C Compressor <br />Ceramic Tile <br />Dryer <br />Decorative <br />Dedicated Outlet <br />Double <br />Diameter <br />Disposal <br />Distance <br />Drawer Stack <br />Dryer Vent <br />Dishwasher <br />Each <br />Each Way <br />Electrical <br />Elevation <br />Exterior <br />Expansion <br /> <br />F.B.C. <br />Fin, Fir. <br />F.G. <br />Fir, <br />Fdn. <br />Fir. Sys, <br />F.PI. <br />Ft. <br />Ftg. <br />FX <br />Galv, <br />G.C. <br />G,F,1. <br />G.T. <br />Hdr, <br />Hgt. <br />HB <br />I nt. <br />K/Wall <br />K.S. <br />Laun. <br />Lav. <br />L.F. <br />L.T. <br />Mas. <br />Max <br />M.C. <br />Mfgr. <br />Micro, <br />Min <br />M,L, <br />Mir. <br />Mono <br />N.T.S. <br /> <br />Florida Bldg. Code <br />Finished Floor <br />Fixed Glass <br />Floor <br />Foundation <br />Floor System <br />Fireplace <br />Foot / Feet <br />Footing <br />Fixed <br />Galvanized <br />General Contractor <br />Ground Fault Interrupter <br />Girder Truss <br />Header <br />Height <br />Hose Bibb <br />Interior <br />Kneewall <br />Knee Space <br />Laundry <br />Lavatory <br />Linear Ft. <br />Laundry Tub <br />Masonry <br />Maximum <br />Medicine Cabinet <br />Manufacturer <br />Microwave <br />Minimum <br />Microlam <br />Mirror <br />Monol ith ic <br />Not to Scale <br /> <br />Opn'g. <br />Opt. <br />Pc. <br />Ped. <br />P.L. <br />PLF <br />PIt. Ht. <br />Pit Sh. <br />PSF <br />P,T. <br />Pwd. <br />Rad. <br />Ref. <br />Req'd. <br />Rm. <br />Rnd. <br />RISH <br />SD. <br />S.F. <br />Sh. <br />SHT <br />S,L. <br />S.P,F. <br />Sq. <br />S.Y.P. <br />Temp. <br />Thik'n. <br />T.O.B. <br />T.O.M. <br />T.O,P, <br />Trans. <br />Typ. <br />UCL <br />U .N.O. <br />VB <br />Vert. <br />V.L. <br />VTR <br />W <br />W/ <br />W/C <br />W.A. <br />Wd <br />WP <br /> <br />MASTER REVISIONS <br /> <br />DATE <br /> <br />DESCRIPTION <br /> <br />Opening <br />Optional <br />Piece <br />Pedestal <br />Parallam <br />Pounds per linear foot <br />Plate Height <br />Plant Shelf <br />Pounds per square foot <br />Pressure Treated <br />Powder Room <br />Radius <br />Refrigerator <br />Required <br />Room <br />Round <br />Rod and Shelf <br />Smoke Detector <br />Square Ft. <br />Shelves <br />Sheet <br />Side Lights <br />Spruce Pine Fir <br />Square <br />Southern Yellow Pine <br />Tempered <br />Thicken <br />Top of Block <br />Top of Masonry <br />Top of Plate <br />Transom Window <br />Typical <br />Under Cabinet Lighting <br />Unless Noted Otherwise <br />Vanity Base <br />Vertical <br />Versalam <br />Vent through Roof <br />Washer <br />With <br />Water Closet <br />Wedge Anchor <br />Wood <br />Water Proof <br /> <br />STRUCTURAL NOTES: <br /> <br />STRUCTURAL DESIGN CRITERIA <br /> <br />FOUNDATIONS <br /> <br />3. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT <br />HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. <br />SHALL HAVE STUD PROTECTION <br />SHIELDS FOR ALL HOLES OVER 1" iN DIA. <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH <br />SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br /> <br />CODES: <br /> <br />FLORIDA BUiLDING CODE, 2001 EDITION WITH 2003 REVISIONS <br />BUILDING CODE REQUIREMENTS FOR REiNFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-02) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br /> <br />FOUNDATION INSPECTIONS <br /> <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDI~G <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRETCHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4, HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />11/2" TO FORM <br /> <br />WOOD FRAMING INSPECTION <br /> <br />LIVE LOADS: <br /> <br />ROOF <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />STAIRS <br />LIGHT PARTITIONS (DEAD LOAD), U,N,O. <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606.2. <br />WIND VELOCITY: 123 M,P.H., USE FACTOR: 1.0 <br /> <br />20 PSF (REDUCIBLE) <br />40 PSF <br />40 PSF <br />40 PSF <br />20 PSF <br />10 PSF ATTIC L,L. <br /> <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, If'..SPECTED <br />AND APPROVED BEFORE REQUESTlr-.G FRAMING <br />INSPECTION, <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER U~LESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE FOLLOWING <br />DESIGN LOADS: <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDAI\CE WITH SPECIFIED LOADS <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION A:'-JD FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRiCATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKlr-.G POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />WIND LOADS: <br />(F. B.C.) <br /> <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />3000 PSI <br />3000 PSI <br /> <br />REINFORCING: <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCII\G BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />ASTM C90-99b, STANDARD WE[GHT UNITS, fm=1500 PSI <br />MORTAR TYPE "S" 1800 PSI <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY [NSPECTION is REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL A~D MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETC, U,N.O. <br />NO.2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB <br />FLOOR SHEATHlr-.G: T&G A-C GROUP 1 APA RATED (48/24) <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.0E) <br />WOOD COLS, PARALLAM 2,OE U.N.O. <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE LOAD: 20 PSF <br />TOP CHORD DEAD LOAD: 10 PSF <br /> <br />STRUCTURAL <br />STEEL: <br /> <br />REINFORCING STEEL <br /> <br />ALL REINFORCING STEEL SHALL BE NEW DEFORMED BARS <br />FREE FROM RUST, SCALE & OIL & SHALL MEET ASTM A-615 <br />REINFORCING FOR FOOTING SHALL BE SUPPORTED ON PRE- <br />CAST CONCRETE PADS, TOP REINFORCING SHALL BE <br />POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. <br />DOWELS FOR COLUMNS & FILLED CELLS SHALL BE SECURED <br />IN PLACE BY USING ADDITIONAL CROSS- REINFORCING TIED <br />TO FOOTING REINFORCING. SPLICES IN REINFORCING WHERE <br />PERMITTED SHALL BE THE FOLLOWING MINIMUM, UNLESS <br />OTHERWISE INDICATED ON THE DRAWIr-.GS: <br /> <br />FTGS, WALLS, COLUMNS, BEAMS, SLABS: 36 DIA. OR 2'-0" MIN" WHICHEVER [S MORE. <br />FILLED CELL REINFORCING: 40 DIA. OR 2'-0" MIN., WHICHEVER IS MORE. <br />TEMPERATURE REINFORCING: 20 DIA. OR 1'-0" MIN., WHICHEVER is MORE. <br />WELDED WIRE MESH: 8" LAP <br /> <br />WOOD FRAMING: <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />BOTTOM CHORD DEAD LOAD: <br /> <br />10 PSF <br />40 PSF <br /> <br />10 PSF <br /> <br />BOTTOM CHORD ATTIC LIVE LOAD: <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 5 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br />MASONRY WALL CONST. <br />1, HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI ( f'm = 1500 PSI) <br />2. MORTAR SHALL BE TYPE "S", CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT, <br />5, VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS, REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWiSE NOTED. <br />6. REiNFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DiAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC <br />SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO <br />PREVENT THE FLOW GROUT INTO CELLS BELOW, THE USE OF FELT <br />PAPER AS A STOP IS PROHIBITED. <br /> <br />UPLIFT CONNECTORS <br /> <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES, <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />15 PSF <br />50 PSF <br />65 PSF <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDIT[ONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO <br />FOUNDAT[ON POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />BUILDING DATA <br /> <br />CONSTRUCTION TYPE - TYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br />MEAN ROOF 15 FT. HIGH <br />TYPICAL FOR SINGLE HOMES <br /> <br />WIND SPEED 123 MPH (3 SEC. GUST) <br />WIND iMPORTANCE FACTOR - (Iw) = 1.0 <br />WIND EXPOSURE - "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.55 (PARTIALLY <br />ENCLOSED BLDG) <br /> <br />WOOD CONSTRUCTION <br /> <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", LATEST EDITION. <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E, BLOCKING OR GABLE END BRACING) SHALL BE EITHER <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br /> <br />DESIGN WIND PRESSURE: <br /> <br />(COMPONENT AND CLADDiNG) WORST CASE (10 SF - END ZONE) <br />WINDOWS AND DOORS <br />123 MPH + 38 PSF / - 40 PSF <br /> <br />GARAGE DOORS (V = 123 MPH) <br />SINGLE 9x7 +37.0 PSF 1 -40.0 PSF <br />DOUBLE 16x7 +37.0 PSF 141.0 PSF <br /> <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br /> <br />ALL WORK SHALL COMPLY WUH AlL <br />PREVAILlNG CODES, FLORIDA BUlLDH\G <br />CODE. NATIONAL ELECTRIC CODE Al~D <br />C1 fY OF ZEPHYRIULLS ORDINANCES <br /> <br /> <br />, . <br />. , <br />. <br /> <br />Hl'IGltII~P~l ~lJ) Pl;~ftl <br />O~ll(1Ltl <br /> <br />HE'J1E~'JEO <br />,'1AY 0 n 2005 <br /> <br />~ t!>tyr <br /> <br />WALDEN GRANDE 2003 STEM WALL <br /> <br />GENERAL NOTES: <br /> <br />THE FOllOWING TECHINCAl CODES <br />SHAll APPLY: <br />2001 FLORIDA BUilDING CODE, <br />WITH 2003 REVISiONS <br />PLUMBING, MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />AND NFPA 70-02 NATIONAL ELECTRICAL CODES <br /> <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WALL MOUNT WATER CLOSET VOLUV1E <br />3.5 GALLONS <br />3, WATER - FLOW RATE, <br />PUBLIC FACILITIES 0,5 G.P.M. <br />PRIVATE FACILITIES 2.2 G.P.M, <br />SHOWER HEADS 2.5 G.P,M. <br />4. ALL WATER LINE PLUMBING <br />TO BE PVPC <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBC. <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />o HANDRAILS - SECTION 1007.5 <br />o GUARDRAILS - SECTION 1015, 1019.9 <br />o STAIRS - SECTION 1007 <br />o CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />o EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />5, ALL OPEI\INGS SHALL COMPLY WITH <br />2001 FBC WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AND O,H. GARAGE DOORS ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFiCATION SHEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTAllATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br /> <br />,.r' <br /> <br />6. ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />7. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS. <br />(SECTION 2405,2) <br /> <br />SHT NO: <br />1 <br />2 <br />2A <br />3 <br />4 <br />5 <br />6 <br />S-1 <br />S-2 <br />S-3 <br />S-4 <br />8-5 <br />S-6 <br />S-7 <br /> <br />S-8 <br />S-9 <br />S-10 <br />S-11 <br />S-12 <br />S-13 <br />S-14 <br />8-15 <br />S-16 <br />S-17 <br />8-18 <br /> <br />INDEX OF DRAWINGS <br /> <br />TITLE <br />COVER SHEET <br />FLOO R PLAN <br />DIMENSION PLAN <br />FOUNDATION PLAN <br />ELECTRICAL PLAN/ INT. ELEV. <br />ELEVATIONS <br />TRUSS LAYOUT <br />MASONRY DETAILS <br />LINTEL PLAN AND DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br />STRUC. NOTES & <br />HANGER INFORMATION <br />DETAILS <br />DETAILS <br />ROOFING DETAILS <br />DETAILS <br />DETAILS <br />PRODUCT APPROVAL <br />WINDOW DETAILS <br />WINDOW DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br /> <br />NOTICE TO BUILDER <br /> <br />IT is THE INTENT OF THIS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT. <br />IN THE EVENT THAT SOMETHING IS UNCLEAR <br />OR NEEDS CLARIFICATION..STOP..AI\D CALL <br />THE DESIGNER LISTED IN THIS TITLE PAGE, IT <br />is THE RESPOI\,SIBILlTY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGI~S AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />BEFORE ANY WORK IS DONE. <br /> <br />W <br />l1..~0::: <br />.00:::0 <br />W l1..l1.. <br />~W""f- <br />~9oS <br />W x~o:.::o <br />() O::Jl1..U <br />L- o:.::OZU <br />.---- CL~w<( <br />o ~0~5 <br />Z wO:::f-z <br />o:.::l1..w <br />W <(zo:.::o <br />,~ OW<(O <br />\..J w:::s:::(/)o <br /><:( f-;:::zz <br />L- 0 0<( <br />.---- ::Jw-w <br />o o~~~ <br />o t8(/)w<(z <br />LL (..:lz~EEQ <br /><(000f- <br />W 5U50:::f-() <br />(:t: or5o:::S:::::J <br /><:( l1..""O::UCL <br />W<<=WOCL <br />:J o:.::of-~<( <br />r-v <( Zw..J-I <br />\..J ::J-I-o:.::-I <br />(f) o(/) ~ (/)- 0 :;: <br />0:::-1"-> <br />-Iw:::;:!o>- <br />-I>~zo::: <br /><(0)<(0 <br /> <br />(/) <br />Q,)Q)-I <br />cn1O~ <br />Q,)._ 0 <br />Q,)U(/) <br />~ ~ Q <br />I (/) ~ <br />cn~CL <br />Q,)c8 <br />- '0.0 u:: <br />ca.- ~ ::J <br />...(/)0:.::00 <br />OQ)w <br />e"CU <br /> <br /> <br />w (..:l 0 <br />I Z co <br />f-_ (/) ~ ~ z <br />(..:lZw <(CDrol ~ <br />(/)~Qo o:.::NCD (/) <br />. of-O Orol~ Z <br />ffiz()u w~~Li 0 <br />W<(-(..:l II~ j:: <br />~tn~z I-I-....LJ :J <br />(..:lo:.::~o 0:.::l1..lJ.Q. ..J <br />ZWCL-I 00.. 0 <br />wO(/):S(/)l1..z~iS (/) <br />WZ(/)a:lZOO c Z <br />I::JzwQ~i=zc:: <br />f- 0 :5 :r: (/) <( 0:.:: 3:::) e" <br />~ZCLf->w1rOa:l V; <br /><( :r: W (/) C::. LiJ <br />tnw~t::o:.::o~a:l: C <br />wgO::::5:('I')Zo:::",:LU _ <br />a:lw::J O<(::J....cc ..... <br />W-II->-OOf-....lJ: C <br />I3ua:NwUC::o 0:: <br />f-O::J""IZ::JCCo:; 0 <br />o:.::""'f-(..:lo:.::oo:=:; <br />2~tn8~U5tnDD ii <br /> <br /> <br />~~ <br />2Q c=J 0 <br />~<(CO <br /> <br />(/) <br />W <br />o <br />(..:l <br />Z <br />o <br />-I <br /> <br />-I <br /><:( <br />0:.:: <br />f- <br />~ <br />o <br />(/) <br />(/) W <br />o U <br />-I ('I') u:: >< <br />a:lo l1..<( <br />wI'- OLL. <br />(..:l N ('I') .;T <br />z('l') ('1')0 <br /><( -I ('I') ('I') <br />0:.:: LL. NN <br />o .. I I <br />.~ 2626 <br />(/) CL 00 00 <br />LDO ~~ <br />.;TCLOO <br />O'l <( .;T.;T <br /> <br />O'l <br />o <br />('1") <br />N <br />o Z <br />00 Q <br />00 <br />~ ~ <br />I- 0 <br />E .;T <br />~ ~z <br /> <br />..S!('I')LD-<( <br />a:lON <br />Q) ~ .-, w <br />1:l.O,~ N <br />t::('1") ,-Iw <br />(tI.....J.;T<(f- <br />0..... l1.. ..-1 0::: <( ..-1 <br />OO::Ju <br />'ro~f--c.o <br />(/)->::oU~..-1 W <br />a..;T ::J f- O'l f- <br />~8.Ig:ffio <( <br />O'l <( CL (/) U Z 0 <br /> <br /> <br />LD <br />o <br />o <br />N <br /> <br />o <br />o <br />Ul <br />W <br />f- <br />:J 0 <br />~ <br />Z Ul .... t"- <br />O 0 .... t"- <br />- > I N <br />Ul ..J (J'\ Ul <br />> m ~ ~ <br />OWMUl <br />~ M t"- <br />A 0 I <br />"I..JM <br />C. U1 lL .... <br />I f- cd: CO <br />~ UJ [l I <br />L W ... <br />r ~ ~ <br />.~ <br />Z <br />o <br />o <br />Ul <br /> <br />o <br />2 w <br />'" 2 <br />v;~(,2 0 <br />Wf-CIlU:J <br />02 V)::::! < <br />O-I> <br />~~'=3:CIl <br /><NWO:~ <br />",rl~Oo <br />20:000 <br />~~w::JU <br />~02=15~ <br />Cl:Jo:CIl~ <br />':Q;;:~oo: <br />2=':Q~~G <br /> <br /> LD <br /> 0 <br /> ('\J(j) "- <br /> N <br /> .z U"- <br /> ~O 1-('1") <br /> <(CL <br /> ('\J- 1'-0 <br /> ~(j) LD"- <br /> > .;T<( <br /> ..-10 <br /> W ':::S::; <br /> 0::: i3~ <br />(0 (f) lJj-.J <br />~ ~ <br />~ -l O-.J w 0 <br /> 0::: <br />-l ~~ () >-l1..z <br /> Zf-O <br />0 <(z- <br />- ZW~ <br />I :c f- -(/)> <br /> o::~ 0 OZo <br />N t30<( <br /> z ::JUo <br />LD S (9lJj OZO:: <br /> owo <br /> Zl- f- 0:.::r=.....J <br />I CL-LL. <br />I'- LLJ I wo:.::-I <br /> lJjCf) 0:.:::5:<( <br /> wwo:.:: <br />~ - (Sl a:lI~ <br />> wO(V) f-f-w <br /> Of-U <br />~ ~ .....J 0 (:t: Z::J . <br />I- >-OCL <br />L() ~ <( 0 >- <I 0::: <br />(f) ~t::0 <br />Z$C'J 0... z3U <br />~ :so:.::w <br />W 0 w2 <br />~ CLZO <br /> ......I (/)ZI <br />>- 0::: 0.. () -<((/) <br /> 2=2::J <br />0::: () SHEET ,\0. CL <br /> 0:.:: <br />0 1 0 <br />(0 U <br /> w <br /> ~ <br />I- ~ 0 <br /> OF I <br />Z ~ 25 (/) <br /> ::J <br /> ('1") <br />LLJ 0 <br />I- 0 <br />> LAST PLOT DATE ('oJ <br /> @ <br />0 March 02, 2005 <br />Z <br />-l COVER SHEET <br />- <br />