<br />I
<br />
<br />INSTALLATION OF WINDOW
<br />BUCK STRIPS - lx3 (MIN). GLUE
<br />STRIP W/ADHESIVE SEALANT
<br />& SCREW Wj3/16" x 2 1/2" PHILLI
<br />FLAT HD. "TAPtON" SCREW MIN.
<br />4" FROM END & 16" O.C.
<br />
<br />
<br />EXT. FINISH
<br />DRIP EDGE
<br />INSTALLATION OF S.G.D.
<br />BUCK STRIPS - lx4 (MINL GLUE
<br />STRIP W/ADHESIVE SEA(ANT
<br />& SCREW W/3/16" x 2 1/2"
<br />PHILLIPS FLAT HD. "TAPCON"
<br />SCREW MIN. 4" FROM END
<br />& 16" O.C.
<br />TRACK - FILL ALL HOLES
<br />W/l" x #8 ST. STL. SCREWS
<br />W/PLASTIC ANCHORS I ....-'
<br />SEALANT
<br />
<br />MASONRY OPENING
<br />S.G.D. INSTALLATION
<br />SCALE: N.T.S
<br />
<br />BLOCK LINTEL
<br />
<br />1/2" DRWALL
<br />BUCKSTRIP - lX3 MIN (WINDOW)
<br />1/8" SHIM Sr1lc\MIN (SGD)
<br />WINDOW/SGD
<br />
<br />~~~k'&~ JAMB
<br />11/2" RECESS
<br />IN SLAB
<br />SLIDING GLASS
<br />DOOR
<br />
<br />@
<br />S-8
<br />
<br /> .. TIE BEAM .
<br /> . PRECAST LINTEL -
<br />(/)
<br />w
<br />0:: FASTEN PT 2X 8 BUCK TO
<br />~
<br /> MASONRY WI 3/16" X 3"
<br /> TAPCONS 6" FROM ENDS
<br /> AND 16" O.C. MAX.
<br /> FASTENING WINDOW TO
<br /> BUCK RESPO~SIBILTY OF
<br /> WINDOW MANUFACTURER.
<br /> /
<br /> /
<br />
<br />
<br />2 X 8 BUCK DETAIL
<br />SCALE: N.T.S,
<br />3-15-04 TH
<br />
<br />L
<br />
<br />3
<br />
<br />
<br />2
<br />
<br />TYP. 8" BLOCK WALL
<br />
<br />
<br />1
<br />6" BITUMINOUS TAPE INSTALLATION SEQUENCE
<br />
<br />EXT. FINISH ---,
<br />JAMB - FILL I
<br />ALL HOLES W/ I
<br />1-1/2"X#8 (MIN')I
<br />SCREW
<br />I
<br />
<br />SEALANT
<br />BACK OF ALL
<br />JAMBS
<br />TRACK. FILl:
<br />ALL HOLES WI
<br />1"X#8 (MIN.)
<br />SCREWS WI
<br />PLASTIC ANCH.
<br />
<br />1 X P.T. W/ 3/16" X 2 1/4"
<br />TAPCONS @ 18" O/C MAX.
<br />& 6" FROM CORNERS
<br />
<br />
<br />WINDOW HEADER
<br />2 - 2"X12" S.Y,P.
<br />UNLESS OTHERWISE
<br />SPECIFIED
<br />_ 1/2" D.w.
<br />:~TRIM
<br />
<br />(SEE PLAN)
<br />S.G,D. JAMB
<br />
<br />'-- 3/4" RECESSED
<br />SLAB
<br />SEALANT
<br />
<br />MAS. WALL EXT.DOOR JAMB
<br />
<br />
<br />
<br />SCALE: N.T.S.
<br />
<br />FRM. OPNG. SGD INSTALL
<br />
<br />SCALE: N.T.S.
<br />
<br />
<br />h
<br />
<br />@:
<br />
<br />I
<br />I
<br />I
<br />
<br />o
<br />@\
<br />
<br />@
<br />
<br />
<br />I
<br />
<br />:@
<br />
<br />a: ) 10 PERCENT OF LEAST HORIZONTAL DIMENSION OR OAh, WHICHEVER IS SMALLER, BUT NOT
<br />LESS THAN EITHER 4% OF LEAST HORIZONTAL DIMENSION OR 3 FT ( 1 m).
<br />
<br />COMPONENT & CLADDING DESIGN PRESSURE
<br />(120 MPH, 3 SEC GUST. 2.1/12 PITCH. EXPOSURE B. HEIGHT = 0 TO 30 FEET, IMPORTANCE FACTOR = 1 )
<br /> (PSF)
<br />TRIBUTARY AREA ROOF WALL
<br />(FT2)
<br /> (GCpi = +1- .18) (GCpi = +1- .18)
<br /> ZONE 1 ZONE 2 & 3 ZONE 4 ZONE 5
<br />10 14,9 -23,7 14.9 -50.1 25,9 -28.1 25.9 -34,7
<br />20 13,6 -23.0 13.6 -45.4 24,7 -26,9 24.7 -32.4
<br />50 11,9 -22,2 11,9 -39,3 23,2 -25.4 23.2 -29.3
<br />100 10,5 -21,5 10,5 -34.7 22,0 -24,2 22.0 -26,9
<br />125 10,5 -21,5 10.5 -34.7 21.7 -23,6 21.7 -26,2
<br />NOTES: 1 FOR EFFECTIVE AREAS OR WIND SPEEDS BETWEEN THOSE GIVEN
<br /> ABOVE THE LOAD MAY BE INTERPOLATED, OTHERWISE USE THE
<br /> LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA,
<br />2 TABLE VALUES SHALL BE ADJUSTED FOR HEIGHT AND EXPOSURE
<br /> BY MUL TIPL YING BY ADJUSTMENT COEFFICIENTS IN TABLE 1606.20
<br /> OF THE FLORIDA BUILDING CODE 2001.
<br />3 PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD
<br /> AND AWAY FROM THE BUILDING SURFACES.
<br />
<br />FILLED CELL WI
<br />#5 VERTICAL
<br />
<br />1/2" X 8" A.B. ~
<br />W/2" WASHERS
<br />SET IN TYP.
<br />FILLED CELL
<br />MIN. 5 PER 0
<br />JAMB. ~ L SECTIONAL
<br /> ~
<br /> OVERH EAD
<br /> 0 DOOR 7
<br />P.T. # ~
<br /> ,
<br />SYP 2" X 6" ~
<br />OVERH EAD J
<br />SECTIONAL ~
<br />DOOR TRACK
<br />W/ 3/8" x 11/2"
<br />STEEL LAG GARAGE SLAB
<br />BOLT W~ :1
<br />WASHE . MIN.
<br />6 PER TRACK ~
<br />TO JAMB. @
<br /> ~ Co
<br />
<br />
<br />(5) 1/2" DIA. x 8"
<br />"J" BOLTS
<br />
<br />
<br />CONT, WOOD TRIM
<br />
<br />2"x6" P,T. WOOD JAMB
<br />
<br />DOOR AND CONNECTION PER
<br />GARAGE DOOR MANUFACTURER
<br />TYP. GARAGE DOOR
<br />
<br />TRACK MOUNTING DETAIL
<br />
<br />SECT. OVERHEAD GAR. DOOR INSTALL
<br />
<br />
<br />SCALE: N.T.S.
<br />3-15-04 TH
<br />
<br />NOTE: THIS DETAIL HAS A CAPACITY THAT IS EQUAL TO OR
<br />GREATER THAN THAT RECOMMENDED BY MANUFACTURER.
<br />
<br />-EQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS
<br />(RE: FBC 2405,1 & 2405.2.1)
<br />
<br />2405,1 General. Individual glazed areas including glass mirrors in
<br />hazardous locations such as those indicated in 2405,2 shall
<br />pass the test requirements of CPSC 16-CFR, Part 1201 or
<br />by comparative test shall be proven to produce at least
<br />equivalent performances.
<br />
<br />Exceptions:
<br />1. Polished wire glass installed in fire doors, fire windows and
<br />view panels in fire resistant walls and hazardous locations in
<br />2405,2.1 (3) and 2405,2.1 (4) shall comply with ANSI Z97.1.
<br />2. Approved plastic materials used as glazing in hazardous
<br />rocations shall comply with ANS I Z97.1.
<br />
<br />2405,2 Hazardous Locations
<br />2405,2.1 The following shall be considered specific hazardous locations for the purpose
<br />of glazing:
<br />1. Glazing in swinging doors and fixed and sliding panels of sliding (patio)
<br />door assemblies.
<br />2 Glazing in doors and walls of enclosures for hot tubs, whirlpools, saunas, steam
<br />rooms, bathtubs, showers, and other such facilities where such glazing is located
<br />36 inches (914 mm) or less, measured horizontally, from a standing or walking
<br />surface within the enclosure and where the bottom edge of the exposed glazing is
<br />less than 60 inches (1524 mm), measured vertically, above such standing or walking surface.
<br />
<br />3. Glazing in an individual fixed or operable panel adjacent to a door where the
<br />nearest vertical edge is within a 24-inch (610 mm) radius of the door in a
<br />closed position and whose bottom edge is less than 60 inches (1524 mm)
<br />above the floor or walking surface,
<br />
<br />EXCEPTION: Glazing in walls perpendicular to the plane of the door in a closed position in
<br />Group R3 or within dwelling units in Group R2 shall be subject to 2405.2,1 (4).
<br />
<br />4. Glazing in an individual fixed or operable panel, other than those locations
<br />descried in items 2 and 3 above, that meets all of the following conditions:
<br />1. Exposed area of an individual pane greater than 9 sq, ft (0.84 m sq.).
<br />2. Bottom edge less than 18 inches (457 mm) above the floor.
<br />3. Top edge greater than 36 inches (914 mm) above the floor.
<br />4. One or more walking surfaces within 36 inches (914 mm)
<br />horizontally of the plane of the glazing,
<br />
<br />5, All glazing in railings regardless of area or height above a walking
<br />surface including structural baluster panelS and non structural in-fill
<br />panels,
<br />6. Glazing in walls and fences enclosing indoor and outdoor swimming
<br />pools and spas where the bottom edge of the glazing is 1) less than 60 inches
<br />(1525 mm) above the walking surface on the pool side of the glazing, and 2)
<br />the glazing is within 60 inches (1525 mm) horizontally of the water's edge of
<br />a swimming pool or spa. This shall apply to single glazing and all panes in
<br />multiple glazing,
<br />
<br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE
<br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE
<br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND
<br />GUST, EXPOSURE "B" WIND ZONE (2001 EDITION).
<br />
<br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE
<br />DATE IS SIGNED AND SEALED.
<br />
<br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />
<br />o
<br />--.J
<br />--.J
<br />
<br />l?
<br />Z
<br />00::
<br />OW
<br />(j)W
<br />Z2
<br /><!l?
<br />02
<br />W
<br />
<br />
<br />
<br />o
<br />.
<br />~
<br />2
<br />o
<br />(j)
<br />0::
<br />W
<br />>
<br />
<br />('I')
<br />o
<br />o
<br />~ (j)
<br />"" 2
<br />~ 0
<br />~ (j)
<br />~ ~
<br />w n:::
<br />:::>
<br />(/)
<br />(/)
<br />
<br />UJ
<br />~ a:
<br />l.L.J W is ~ s:
<br />O~~~~
<br />~ - 0 ::l
<br />f- x (/) cr: 0
<br />o !;:; u.. u
<br />05:oz~
<br />2 ~:2:!i:!.
<br /><l: 0 <l: 5
<br />W :i!B:~z
<br />,~ <l: z cr: 0
<br />'-IoUJ<l:O
<br /><! CJ.I ~ (/) 0
<br />f- ~<l:Z2:
<br />o ~ 0 <l:
<br />O ::l UJ - CJ.I
<br />0'~~:2:
<br />9 :{] (/) UJ ~
<br />...... I.:l Z ~u..
<br /><l: 000
<br />W I-Vicr:1-
<br />1'Y8zo~
<br />~ lI,UJi'i':U
<br />....... W ~ W 0
<br />=> ~1S~a:j
<br />O::l::J--:cr:
<br />g~~~
<br />(j) ...JUJ~O
<br />~~:;~
<br />
<br />l!')
<br />o
<br />o
<br />Noo l.L~~
<br />1'-0) oU'
<br />l!)(O Wo
<br />~O) ~af:!
<br />,l!) ffig:iB
<br />0::( ~ 0... (/) 1:
<br />0(0 ~i:~
<br />0:: (Y) 0... f- 0...
<br />O...-i ~6 ~
<br />u:~ Q~~
<br />UJ ~ ::l
<br />I ~ ~d [3
<br />~u: WW~
<br />I.JJ 0:: 1: a:
<br />ro <l:f-O
<br />(/) 0 J:
<br />o(Ooozzf-
<br />.....I (O~ I.:l <l: ~
<br />O.....l(jO'lVi:3z
<br />l!) W...J ::l
<br />9;: l!)N 0 . cr:
<br />......~ 000
<br />, ,no::( ZZ .~
<br />.......0 <l: - ~
<br />0_ (/)[5 Q
<br />0cY> 0CJ.11-
<br />~~ ZZ~
<br />('I')~ 3S3o
<br />><, ~t5~
<br />g IJ.J 000...
<br />Z UW
<br />. 0 W(/) cr:
<br />OI f{jZ>-
<br />cLn.. ~C3~
<br /><0
<br />
<br />If) 00 N
<br />.q- I.!) N
<br />N I'- ...-1
<br />.q- m 0
<br />('t") .q- <.0
<br />W W w
<br />a.: 0.. a.:
<br />
<br />~
<br />Q)
<br />.0
<br />C
<br />Q)
<br />'" C ,-
<br />~ 0 ->-
<br />- C
<br />(.9 rj) >-
<br />C ::J
<br /><t: ~ :.r:
<br />Q) ~ :i
<br />::J
<br />E ,~ ~
<br />,co/~ ~
<br />[BOD
<br />
<br />
<br />o
<br />~
<br />......
<br />......
<br />. I
<br />'CJ)
<br />o
<br />~f:::
<br />C")N
<br />-.JU(
<br />lJ..cn
<br />_r.o
<br /><tl'-
<br />n.'
<br />~~
<br /><to?
<br />f-......
<br />
<br /> z
<br /> o.
<br /> -0
<br /> ~>
<br /> >-.J
<br /> -ro
<br /> Ow
<br /> <t~
<br /> go
<br /> ~I
<br /> OU)
<br /> .....If-
<br /> lJ..(/)
<br /> .....IWD
<br /> ~~g
<br /> f-zW
<br /> zot:
<br /> wo::)
<br /> Ur.o(/)
<br /> (/)
<br /> .....J
<br /> .....J
<br /> -
<br /> :c
<br />>- $ (V)
<br />w 0 0::0.:
<br /> wO::
<br />0::: - 0 W zo
<br />> ZU
<br /> -<w
<br />0 N 0 :2: :2:
<br />r- >-0
<br />r- z :I:
<br />(/) 0 ..... -<(/)
<br /> =>
<br />Z ?; :2:
<br />lLJ 0:: 0 00
<br /> W 0::
<br />W ULl..
<br />0::: 0 Z =>1-
<br />> OZ
<br /> ow
<br />() w LL ..... O::(/)
<br /> n..zz
<br />Z >< :r: woo
<br /> ~ O::u-
<br />- ~ 0 ~ Wz~
<br /> -< IDw>
<br /> I-~O
<br />"0 (f) 2 0::: ~cr:o:t:
<br />gj~ >-39
<br />--.J -<wo::
<br />~ Z >- :2::I:g
<br />-< 0... zl-Ll..
<br />~ () :51----1
<br />W .....J 0 n..6~
<br />0 0 0 ~~~
<br />a.. 0 :I:-W
<br />I .....J lY: 1-3u
<br />C\J 0
<br />CO SHEET NO. n.
<br />1.0 0 0::
<br /> 0
<br /> 0 0
<br />I C\J 8-8 w
<br />t'- 06 ~
<br />~ C\J S 0
<br /> I
<br /> (/)
<br />~ 0 ::)
<br />.- 0 l!)
<br /> 0
<br />1.0 0 z 0
<br /> N
<br />~ .....J S LAST PLOT C0
<br />DATE: April 11, 2005
<br />
<br />NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO RE'VIEW ALL
<br />DRAWINGS BEFORE CONSTRUCTION BEGINS, DANSCO
<br />ENGINEERING, LLC IS RESPONSIBLE FOR THE STRUCTURAL
<br />INTEGRIfY' Of THIS PROJECT ONl Y. ANY DISCREPANCY BETWEEN
<br />FIELD CONDITIONS, O-:-HER DESIGN PROFESSIOMLS' SHOP DRAWINGS,
<br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED
<br />DRAWINGS MUST BE BROUGHT TO THE ATTENTION Of DA.NSCO
<br />ENGINEERING, LlC PRIOR TO THE COMMENCEMENT OF CONSTRUCTION,
<br />
<br />,
<br />,
<br />,
<br />I
<br />,
<br />I
<br />I
<br />I
<br />,
<br />I
<br />/
<br />I
<br />I
<br />I
<br />\
<br />\
<br />\
<br />\
<br />,
<br />,
<br />,
<br />,
<br />....,
<br />
<br />
<br />,
<br />,
<br />....
<br />....
<br />,
<br />,
<br />\
<br />\
<br />\
<br />\
<br />
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />
<br />t\t>R 1 1~~~~'/
<br />
<br />
<br />--------
<br />
<br />PLACE SEAL HERE DE #250992
<br />
|