<br />Termite Specifications: <br /> <br />Structural Notes: <br /> <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />FOUNDATIONS <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br />FOUNDATION INSPECTIONS <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COpy OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRECHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />1 1/2" TO FORM <br />MASONRY WALL CONST. <br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI ( fm = 1500 PSI) <br />2. MORTAR SHALL BE TYPE "M" OR "SO, CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C475 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWISE NOTED. <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. DUR-O-WALL SHALL BE PROVIDED @ EVERY OTHER <br />COARSE OR 16" o/c <br />WOOD CONSTRUCTION <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", 2001 EDITION. <br />2. ALL EXTERIOR WOOD STUD WAllS, BEARING WALLS, SHEAR <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E. BLOCKING OR GABLE END BRACING) SHAll BE EITHER <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br />3. ANY WOOD FRAME BEARING WALL STUDS THAT ARE CUT <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH <br />SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br />4. ALL STUCCO FINISH OVER EXTERIOR FRAME MUST BE 7/8" THICK <br />PER ASTM C. 926-APPLY 3 LAYERS WITH TOTAL THICKNESS 7(8" <br />OVER METAL LATH. <br />FIRST 2 LAYERS 3(8" THICK EACH. 3RD LAYER 1(8" THICK. <br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH <br />EARTH OR CONCRETE TO BE PRESSURE TREATED. <br /> <br />*ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE <br />(CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR <br />GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED <br />WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C, <br />MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS <br />THAT ARE CORROSIVE TO STEEL IT IS THE CONTRACTOR'S <br />RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO <br />SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. <br />FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT-DIPPED <br />GALVANIZED OR STAINLESS STEEL FASTENERS. <br />DOT SODIUM BORATE (SBX) DOES NOT. <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />CODES: <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED (WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE DESIGN <br />LOADS AS LISTED ON THE STRUCTURAL DESIGN CRITERIA <br />6. DESIGN SPEOFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFlED LOADS <br />AND GOVERNING CODES. SUBMmALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND(OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />WOOD FRAMING: <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br /> <br />LIVE LOADS: <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br /> <br />DEAD LOADS: <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5(8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br /> <br />5. INITIAL TREATMENT SHAll BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE.(FBC 1816.1.1) <br /> <br />WIND LOADS: <br />(F.B.C.) <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED.(FBC 1816.1.2) <br /> <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASlIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL EUMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br /> <br />REINFORCING: <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED.(FBC 1816.1.4) <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br /> <br />STRUCTURAL <br />STEEL: <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-CONSTRUCTION TREATMENT.(FBC 1816.1. 7) <br /> <br />UPLIFT CONNECTORS <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANf.A.N <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816.1.7) <br /> <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br /> <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br /> <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br /> <br />FIELD REPAIR NOTES <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />WOOD FRAMING INSPECTION <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION. <br /> <br />1. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY <br />BE SUBSTITUTED W/ (1) "SIMPSON MTSM16 TWIST STRAP W/ <br />(4) 1/4" X 2 1/4" DIA. TITENS TO THE BOND BEAM BLOCK <br />AND (7) lOd TO THE TRUSS FOR UPLIFTS OF 1000 LBS. OR <br />LESS. USE (2) FOR 2000 LBS. OR LESS. OTHERS MAY BE <br />SUBSTITUTED ON A CASE BY CASE BASIS. <br />2. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUB- <br />STITUTED W/l/2" DIA. ANCHOR BOLTS SET IN 3(4" DIA. X 6" <br />DEEP UNITEX "PROPOXY" 300 ADHESIVE BINDER FOLLOWING <br />ALL MANUFACTURERS RECOMMENDATIONS ( OR 1/2" X 6" <br />RAWL STUD EXPANSION ANCHORS. ) <br /> <br />3. REGARDING MISSED REBAR IN VERTICAL FILLED CELLS: <br />DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF <br />THE OMmED REBAR, AND INSTALL A 32" LONG #5 BAR INTO <br />THE EPOXY FILLED HOLE. USE A TWO PART EMBEDDEMENT <br />EPOXY ( SIMPSON "EPOXY TIE SET', OR HIL TI " 2 PART' <br />EMBEDDMENT EPOXY ), MIXED PER MANUFACTURER'S <br />INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM <br />DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND <br />AND USING COMPRESSED AIR PRIOR TO APPLYING THE EPOXY. <br />ALLOW THE EPOXY TO CURE TO MANUFACTURER'S SPEOFlCATIONS, <br />THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM <br />POUR. <br />4. HURRICANE STRAPS MAY BE SUBSTITUTED WITH A STRAP OF <br />GREATER HOLDOWN VALUE OR GREATER UPLIFT VALUE IN THE <br />FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURERS <br />INSTALLATION INSTRUCTIONS ARE FOLLOWED. <br />5. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. <br />IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES <br />NOT HAVE TO BE CONT. TO FOOTING) <br /> <br /> General Notes: <br /> ~ w <br /> o i!: <br /> THE FOLLOWING TECHINCAL CODES ~~~ ~ <br /> SHALL APPLY: i!: 8- <br /> . 1=1 ~ ~ <br /> () <br /> 2001 FLORIDA BUILDING CODE, Z <br /> PLUMBING, MECHANICAL, FUEL GAS, Nco ~~~ ;~ ~ <br /> ENERGY EFFICIENCY, ACCESSIBILITY, ~ ~o <br /> z tO~9~ <br /> AND 2002 NATIONAL ELECTRICAL CODES 0:: ~8~ ~ ; <br /> w ~ glB~ C'2 <br /> w z ~. ~ <br /> ORDINANCE 92-19 - APPENDIX "J" O)N g-W 00 ~ <br /> z )( ...... to ~i!:;ii!~ ~ c:::r. <br /> TO FBC PLUMBING 2001 CODE. ~ oti,.,...... ;a <br /> CD .....,.,. ~~~ ~ra ~u <br /> z ~.e iii ~ <br />1. TANK TYPE WATER CLOSET VOLUME W d ........w ~c~ i~ UlI <br /> 1.6 GALLONS a.: .. <br /> ....J v <br />2. WALL MOUNT WATER CLOSET VOLUME ~ ~~ ~~t1 !" ~ <br /> 3.5 GALLONS ~ ll. ~~ CC ra~ <br />3. WATER - FLOW RATE. W :~~ ~~ ~l!5 <br /> f- <br /> 0.5 G.P.M. Z <br /> PUBLIC FAOLITIES . . . <br /> PRIVATE FACILITIES 2.2 G.P.M. <br /> SHOWER HEADS 2.5 G.P.M. <br /> ALL PLUMBING WATER LINES <br /> TO BE PVPC <br /> <br />Structural Design Criteria: <br /> <br />FLORIDA BUILDING CODE, 2001 EDITION <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (AO 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-89) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (AeI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />ROOF <br />TOP CHORD <br />BOTTOM CHORD (W (0 STORAGE) <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />STAIRS <br /> <br />ROOF <br />FLOOR <br /> <br />20 PSF <br />10 PSF <br />40 PSF <br />40 PSF <br />40 PSF <br /> <br />17 PSF (SHINGLE) <br />15 PSF <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606.2. <br />WIND VELOCITY: 123 M.P.H., USE FACTOR: 1.0 <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />2500 PSI <br />3000 PSI <br /> <br />4. <br /> <br /> <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCING BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBC. <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />o HANDRAILS - SECTION 1007.5 <br />o GUARDRAILS - SECTION 1015, 1019.9 <br />o STAIRS - SECTION 1007 <br />o CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />!Xl EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />ASTM C90 OR C129, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MORTAR TYPE "SO 1900 PSI <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O. <br />NO.2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-(fC-D, EXTERIOR, or OSB <br />FLOOR SHEATHING: 3/4" PLYWOOD (5 PLIES) OR 3/4" T&G ADVANTECH <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.0E) <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE AND DEAD LOAD: <br />BOTTOM CHORD LIVE AND DEAD LOAD: <br />TOTAL: <br /> <br />27 PSF <br />20 PSF <br />47 PSF <br /> <br />NET UPLIFT DESIGN PRESSURE: 20 PSF WITHIN <br />4 FEET OF RIDGES, HIPS, EAVES AND BUILDING <br />PERIMETER AND 15 PSF MIN FOR ALL OTHER AREAS, <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFlED CODES, DEDUCTING <br />A MAXIMUM OF 10 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br />15 PSF <br />40 PSF <br />55 PSF <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFlCATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO <br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />Building Data: <br /> <br /> <br />s <br />o <br />u <br />U <br />~ 8-j .S <br />.9 ll) ~ ] <br />]] cr;ooo ~ <br />~~ ~~~~affi <br />OJ"' OJ t-:-.....I ..... ~ <br />...:0::: ..0'1'.... rJl <br />ro ro ro t-:- g; OJ <br />~U5t-:-~~~~8 <br />~~.~ OJ~~ ~~ <br />U("HJ)Oo..~ ~~ <br /> <br />UJUJUJ <br />~l.9u <br /><!~~ <br />=>00 <br />SSf(z <br /> <br />\n \n X z <br />A UJ- Z ~ :1 ~ ~ 0 8 9:: 0 <br />~~~o~tnoiliot(g <br />~gHffi~s:ffi~~z~~ <br />:Jox.~zu.~zo~:Ja. <br />o\n~o(J;lOo~aUJoe.. <br />\nUJa.;O(w ~u-... <br />-l~~::lf-"9~~~;:2~-l <br />~f-" ;:2UJ~O~wwu. ~ <br />Q~w~:J ~~Qb~ <br />t(~> Oz r-z~ <br />0.... 0 <br /> <br /> <br />Index Of Drawings <br /> <br />4. ALL OPENINGS SHALL COMPLY WITH <br />2001 FBC WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AND O.H. GARAGE DOORS ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br /> <br />5. ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />6, ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS. <br />(SECTION 2405.2) <br /> <br />WIND SPEED 123 MPH <br />WIND IMPORTANCE FACTOR -- (Iw) = 1.0 <br />WIND EXPOSURE -- "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.55 (PART. ENCLOSED) <br /> <br />SHT NO: <br /> <br />CONSTRUCTION TYPE -- TYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br /> <br />WIND BORNE DEBRIS AREAS <br /> <br />THE METHOD TO SATISFY PROTECTION OF OPENINGS <br />IN THESE AREAS WILL BE THE SOLE RESPONSIBILITY <br />OF THE CONTRACTOR. <br /> <br />DESIGN WIND PRESSURE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br /># END ZONE IS ONLY WIn~IN 5'-0" <br />OF ALL EXTERIOR BUILDING CORNERS <br /> <br />A <br />A1 <br />A2 <br />A3 <br />A4.1 <br />A4.2 <br />A4.3 <br />AS.1 <br />AS.2 <br />AS.3 <br />A6 <br />S-l <br />S-2 <br />S-2A <br />S-3 <br />S-4 <br /> <br />S-6 <br />S-7 <br /> <br />THEIR OPTIONS ARE AS FOLLOWS: <br /> <br />WINDOWS AND DOORS <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br /> <br />A. IMPACT RESISTANT GLAZING <br />B. APPROVED SHUTTERS <br />C. SUPPLY WOOD STRUCTURAL PANELS <br />PER FBC 1606.1.4 <br /> <br /> <br />Master Revisions: <br /> <br />DATE <br /> <br />DESCRIPTION <br /> <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORIDA BUlLDil':G <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYRHILLS ORDINANCES <br /> <br />.... <br />,:.i <br />! <br />~ <br />g: <br />N <br />8 <br />~ <br />"- <br />N <br />"- <br />'" <br />~ <br />~ <br />J <br />~ <br /> <br />..: <br />~ <br />~ <br />~ <br />j <br />~ <br />I <br />~ <br />~ <br />o <br />] <br />j <br />1 <br />I <br />,2 <br />...-, <br />...- <br /> <br />REVIEWED <br />HAY 1 0 Z005 <br />~bWr <br /> <br />CENTRAL FLORIDA DIVISION, <br />TAMPA, FLORIDA 33609 <br /> <br />ENGINEERED PLANS <br />ON FILE <br /> <br />S-8 <br />S-9 <br />S-10 <br />S-l1 <br />S-12 <br /> <br />UJ <br />::E <br />o~ <br />~z <br />U~ <br />o SHEET NO. <br />- <br /> <br />co <br /> <br />nE <br /> <br />COVER SHEET <br />FLOOR PLAN <br />FOUNDATION PLAN <br />ELECTRICAL PLAN <br />ELEVATION I <br />ELEVATION II <br />ELEVATION III <br />ROOF FRAMING ELEV I <br />ROOF FRAMING ELEV II <br />ROOF FRAMING ELEV III <br />INTERIOR ELEVATIONS <br />FOUNDATION DETAILS <br />LINTEL DETAILS <br />LINTEL PLANS <br />ROOF FRAMING (I, II, III) <br />BRACING DETAILS <br />WALL SECTIONS <br />STRUCTURAL NOTES & <br />HANGER INFORMATION <br />WINDOW & DOOR DETAILS <br />WINDOW & DOOR DETAILS <br />WINDOW & DOOR DETAILS <br />WINDOW & DOOR DETAILS <br />PRODUCT APPROVAL INFO <br /> <br />L() V) <br /> c <br />C\I 0 <br /> 'ij) <br /> '5 <br />~ ~ <br />0 a-: <br /> ~ <br />I (J) <br />C\I - <br />- <br />.- <br />L() :r: <br />I ~ <br />I'-- Q) <br /> .- <br />~ > <br /> ....., <br />~ (J) <br />L() Q) <br />L- <br />~ () <br /> <br />>- <br />C!: <br />o <br />I- <br />Z <br />W <br />> <br />Z <br /> <br />Notice To Builder <br /> <br />600 N. WESTSHORE BLVD. SUITE 600 <br />(813) 769-5277 <br /> <br />IT IS THE INTENT OF THIS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT. <br />IN THE EVENT THAT SOMETHING IS UNCLEAR <br />OR NEEDS CLARlFICATION..STOP..AND CALL <br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT <br />IS THE RESPONSIBILITY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />BEFORE ANY WORK IS DONE. <br /> <br />ANDOVER 2005 <br /> <br />L() <br />C\.I <br />~ <br />LAST PLOT DATE <br />15 Mar. 23. 05 <br /> <br />-J COVER SHEET <br /> <br />- <br /> <br />o <br />o <br />\D <br />~ <br />::l <br />Z(/) <br />O. <br />........ "0 <br />(/) > <br />........- <br />>C!l <br />........ <br />~ 0 ~ <br />.. <( 0 <br />a....c <br />":E~ <br />~~ <br /> <br />l.() <br />o <br />o <br />N <br /> <br />- <br />- <br /> <br />ro <br />3: <br />E <br /><lJ <br />"'-' <br />(/) <br /> <br />1- <br />OJ <br />> <br />o <br />""0 <br />C <br /><( <br /> <br />A <br /> <br />. <br />Z <br />o <br />o <br />\D <br /> <br />o <br />~ <br />~f' <br />~f' <br />IN <br />enLl') <br />01 <br />\Den <br />M\D <br />Mf' <br /> <br />- I <br />LLM <br />ro~ <br />c.CO <br />E~ <br />ro <br />I- <br /> <br />>-1- <br />~z <br />z~ <br />UJHZZ <br />ufi38~ <br />~~z~ <br />o8~o <br />Z a:: ~ <:( <br />o..~o. <br />I-~w~ <br />:r:~~~ <br />19 I- I- :E <br />~o::)o <br />0:::: Z 0 ::c <br />>-~~~ <br />a..:E3::?: <br />O~a::o <br />U:)wa:: <br />o..zll.. <br />V"lZ <br />He::( <br />::C:E <br />I- <br /> <br />~ <br />8 <br />w <br />:E <br />o <br />::c <br />V"l <br />::) <br />lJ) <br />o <br />~ <br />@ <br />