<br />TERMITE SPECIFICATIONS: <br /> <br />STRUCTURAL No-rES: <br /> <br /> <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br /> <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BElWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br /> <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE.(FBC 1816.1.1) <br /> <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED.(FBC 1816.1.2) <br /> <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED.(FBC 1816,1.4) <br /> <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-CONSTRUCTION TREATMENT.(FBC 1816.1.7) <br /> <br />13. A CERTIFlCATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816.1.7) <br /> <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br /> <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br /> <br />FOUNDATIONS <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFlED PROCTOR) <br />FOUNDATION INSPECTIONS <br />A FOUI\DATION SURVEY SHALL BE PERFORMED AND A <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRECHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />11/2" TO FORM <br />MASONRY WALL CONST. <br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM COO, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI ( f'm = 1500 PSI) <br />2. MORTAR SHALL BE TYPE "M" OR "S", CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWISE NOTED. <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. DUR-O-WALL SHALL BE PROVIDED @ EVERY OTHER <br />COARSE OR 16" O/C <br /> <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORlDA BUILDn~'J <br />CODE, NATIONAL ELECTRlC CODE AND <br />CfrY OF ZEPHYRHlLLS ORDINANCES <br /> <br />WOOD CONSTRUCTION <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", 2001 EDITION. <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E. BLOCKING OR GABLE END BRACING) SHALL BE EITHER <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br />3. ANY WOOD FRAME BEARING WALL STUDS THAT ARE CUT <br />FOR PLUMBING LINES, ETC, SHALL BE REPAIRED WITH <br />SIMPSON HSS2 STUD SHOES,TYP., U,N.O. <br />4. ALL STUCCO FINISH OVER EXTERIOR FRAME MUST BE 7/8" THICK <br />PER ASTM C. 926-APPLY 3 LAYERS WITH TOTAL THICKNESS 7/8" 3. <br />OVER METAL LATH, <br />FlRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. <br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH <br />EARTH OR CONCRETE TO BE PRESSURE TREATED. <br />*ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE <br />(CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR <br />GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED <br />WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. <br />MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS <br />THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S <br />RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO <br />SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. <br />FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT-DIPPED <br />GALVANIZED OR STAINLESS STEEL FASTENERS. <br />DOT SODIUM BORATE (SBX) DOES NOT. <br />WOOD FRAMING INSPECTION <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION. <br /> <br />l1EVIEWED <br />HAY 06 2005 <br /> <br />1k- s&vr <br /> <br />MASTER REVISIONS <br /> <br />DATE <br /> <br />DESCRIPTION <br /> <br />ENGINEERED PLANS <br />ON FILE <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFlCATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AI\D CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE DESIGN <br />LOADS AS LISTED ON THE STRUCTURAL DESIGN CRITERIA <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />UPLIFT CONNECTORS <br /> <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED, PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br /> <br />FIELD REPAIR NOTES <br /> <br />1. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY <br />BE SUBSTITUTED W/ (1) "SIMPSON MTSM16 TWIST STRAP W/ <br />(4) 1/4" X 21/4" DIA. TlTENS TO THE BOND BEAM BLOCK <br />AND (7) 10d TO THE TRUSS FOR UPLIFTS OF 1000 LBS. OR <br />LESS. USE (2) FOR 2000 LBS. OR LESS, OTHERS MAY BE <br />SUBSTITUTED ON A CASE BY CASE BASIS. <br />2. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUB- <br />STITUTED W/ 1/2" DIA. ANCHOR BOLTS SET IN 3/4" DIA. X 6" <br />DEEP UNITEX "PROPOXY" 300 ADHESIVE BINDER FOLLOWING <br />ALL V1ANUFACTURERS RECOMMENDATIONS ( OR 1/2" X 6" <br />RAWL STUD EXPANSION ANCHORS. ) <br />REGARDING MISSED REBAR IN VERTICAL FlLLED CELLS: <br />DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF <br />THE OMITTED REBAR, AND INSTALL A 32" LONG #5 BAR INTO <br />THE EPOXY FILLED HOLE. USE A TWO PART EMBEDDEMENT <br />EPOXY ( SIMPSON "EPOXY TIE SET", OR HILTI " 2 PART" <br />EMBEDDMENT EPOXY ), MIXED PER MANUFACTURER'S <br />INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM <br />DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND <br />AND USING COMPRESSED AIR PRIOR TO APPLYING THE EPOXY. <br />ALLOW THE EPOXY TO CURE TO MANUFACTURER'S SPECIFICATIONS, <br />THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM <br />POUR. <br />4. HURRICANE STRAPS MAY BE SUBSTITUTED WITH A STRAP OF <br />GREATER HOLDOWN VALUE OR GREATER UPLIFT VALUE IN THE <br />FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURERS <br />INSTALLATION INSTRUCTIONS ARE FOLLOWED. <br />5. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. <br />IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES <br />NOT HAVE TO BE CONT. TO FOOTING) <br /> <br />CENTRAL FLORIDA DIVISION <br />600 N. WESTSHORE BLVD. <br />SUITE 600 <br /> <br />STRUCTURAL DESIGN CRITERIA <br /> <br />CODES: <br /> <br />FLORIDA BUILDING CODE, 2001 EDITION <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318--02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-89) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />LIVE LOADS: <br /> <br />ROOF <br />TOP CHORD <br />BOTTOM CHORD (W/O STORAGE) <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />STAIRS <br /> <br />ROOF <br />FLOOR <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606.2, <br />WIND VELOCITY: 120 M.P.H., USE FACTOR: 1.0 <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />3000 PSI <br />3000 PSI <br /> <br />DEAD LOADS: <br /> <br />20 PSF <br />10 PSF <br />40 PSF <br />40 PSF <br />40 PSF <br /> <br />17 PSF (SHINGLE) <br />15 PSF <br /> <br />WIND LOADS: <br />(F.B.C.) <br /> <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />REINFORCING: <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCING BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM C90 OR C129, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MORTAR TYPE "S" 1900 PSI <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />STRUCTURAL <br />STEEL: <br /> <br />WOOD FRAMING: <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O. <br />NO.2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB <br />FLOOR SHEATHING: 3/4" PLYWOOD (5 PLIES) OR 3/4" T&G ADVANTECH <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.0E) <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE AND DEAD LOAD: <br />BOnOM CHORD LIVE AND DEAD LOAD: <br />TOTAL: <br /> <br />27 PSF <br />20 PSF <br />47 PSF <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />NET UPLIFT DESIGN PRESSURE: 20 PSF WITHIN <br />4 FEET OF RIDGES, HIPS, EAVES AND BUILDING <br />PERIMETER AND 15 PSF MIN FOR ALL OTHER AREAS. <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 10 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br />15 PSF <br />40 PSF <br />55 PSF <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFlCATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO <br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />BUILDING DATA <br /> <br />CONSTRUCTION TYPE - TYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br /> <br />WIND SPEED 120 MPH <br />WIND IMPORTANCE FACTOR - (Iw) = 1.0 <br />WIND EXPOSURE - "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 (ENCLOSED BLDG) <br /> <br /> <br />WIND BORNE DEBRIS AREAS <br /> <br /> <br />TO SATISFY PROTECTION OF OP GS <br />IBILlTY <br /> <br />DESIGN WIND PRESSURE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br /># END ZONE IS ONLY WITHIN 5'-0" <br />OF ALL EXTERIOR BUILDING CORNERS <br /> <br />WINDOWS AND DOORS <br />120 MPH + 25.9 PSF / - 34.7 PSF (END) <br />+ 25,9 PSF/-28,1 PSF (INTERIOR) U.N.O. <br /> <br />GARAGE DOORS (V = 120 MPH) <br />SINGLE 9x7 +25 PSF / -32.0 PSF <br />DOUBLE 16x7 +24 PSF / -24.5 PSF <br /> <br />SEE ELEVATION PAGE FOR ACTUAL PRESSURES <br /> <br />TAMPA, FL 33609-1140 <br />1-813-769-5277 <br /> <br />OXFORD 2003 <br /> <br />GENERAL NOTES: <br /> <br />L!) <br />o <br />o <br />() NOO ,.:N <br />-.J [D 0) ~ ~ '. <br />-.J ('f)<D ~o53 <br />('I') 0) 0:: 0:: t:: <br />~ ,li) wQ.iIl <br />o <(0 --t Q. (/) I <br />Z <D ~I~ <br />O-!Xc;:) Q.~Q. <br />,.,0::: O~ ~o~ <br />CI)"""'w u:~ Ol-llJ <br />__Z(/) <br />ZwZ wCJ.J~ <br />I~ ~d53 <br /><(0 ~u.: ~w~ <br />Oz co <ti!:o <br /><D (/) a :r: <br />W O<DOO zz~ <br />~-.J~--t Q<<t <br />600) f2~5 <br />CLli)li) a...Jo:: <br /><(--tN ado <br />'<D<( z~z <br />o ~o ~ ffi 0 <br />0('1') <.:lwi= <br />--t~ ZzU <br />Q~~ ~~~ <br />g~ a8 fri <br />'0 ~(/)Cl:: <br />q I ~ ~H~ <br />CLCL I-a<t <br />e <br /> <br />THE FOLLOWING TECHINCAL CODES <br />SHALL APPLY: <br /> <br />w <br />:?Eo::: <br />w'~~f2 <br />ll.J """WLLf- <br />o <(O:?Ez <br />:?E-o~ <br />I- x~cro <br />O o~u::u <br />O:::Ozu <br />z ~~~::: <br /><(0<(0 <br />W wO:::f-z <br />D:::LLW <br />(!) <(zo:::o <br /><( OW<(O <br />I- wx(/)o <br />t-;:::zz <br />O 0 0<( <br />~w-w <br />~ ~~ffi~z <br />W 0Z~LLQ <br />0::: ~Qoo~ <br />o~crf-u <br /><( otljox:J <br />-"\ LL"",cr:Ua.. <br />-oJ wc:wOa.. <br />r"V O:::QI-i6<( <br />\..J <(....Jz ....J <br />CI) ~....J-_cr....J <br />0'<((/)0<( <br />(/)D:::....J,~ <br />::l~~~o::: <br /><(0;:><(0 <br /> <br />2001 FLORIDA BUILDING CODE, <br />PLUMBING, MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />AND 2002 NATIONAL ELECTRICAL CODES <br /> <br />ORDINANCE 92-19 - APPENDIX "J" <br />TO FBC PLUMBING 2001 CODE. <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WALL MOUNT WATER CLOSET VOLUME <br />3.5 GALLONS <br />3. WATER - FLOW RATE. <br />PUBLIC FACILITIES 0.5 G.P.M. <br />PRIVATE FACILITIES 2.2 G.P.M. <br />SHOWER HEADS 2.5 G.P,M. <br />4. ALL PLUMBING WATER LINES <br />TO BE PVPC <br /> <br />o <br />oM <br />Z <br />o <br />CI) <br />0::: <br />ll.J <br />> <br /> <br />('I') <br />o <br />o <br />~ CI) <br />N Z <br />~ 0 <br />.-i <br />W CI) <br />~ > <br />o W <br />~ 0::: <br />(/) <br />~ <br /> <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBC. <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />o HANDRAILS - SECTION 1007.5 <br />o GUARDRAILS - SECTION 1015, 1019.9 <br />o STAIRS - SECTION 1007 <br />o CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />o EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />LO 00 ('oJ <br />'<t LO ('oJ <br />N I'- ~ <br />'<t Q) 0 <br />('1) ..;t c.o <br />W W W <br />ll.. ll.. ll.. <br /> <br /> <br />P!l <br />ill <br />.0 <br />C <br />ill c <br />~ 0 <br />~ (/) <br />c <br /><i ~ <br />ill .. I <br />:) <br />E .S: ~ <br /> <br />'~~~ <br /> <br />I\PR /1 zea; <br /> <br />4. ALL OPENINGS SHALL COMPLY WITH <br />2001 FBC WI N D LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AND O.H. GARAGE DOORS ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br /> <br />..c <br />c <br />>- <br />:) <br />I <br /> <br /> <br />5. ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />6. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS, <br />(SECTION 2405.2) <br /> <br />o <br />V" <br />...... <br />..- <br />m <br />o <br />(Of'- <br />C"')f'- <br />,C"')N <br />'-.JUI <br />u.dl <br />. (0 <br /><(f'- <br />a.."" <br />~...... <br />~'? <br />I r- ...... <br />I <br />I <br />.1 <br /> <br />INDEX OF DRAWINGS <br /> <br />SHT NO: <br /> <br />TITLE <br /> <br />A COVER SHEET <br />1 FLOOR PLAN <br />1A DIMENSION FLOOR PLAN (/) <br />2 STEM FOUNDATION PLAN --.J <br />3 ELECTRICAL PLAN --.J <br />4 ELEVATION PLAN (II) - <br />S-1 STEM FOUNDATION DET. I <br />S-2 LINTEL DETAILS <br />S-2A LINTEL PLANS $ <br />S-3 ROOF FRAMING (II) >- <br />S-4 GABLE DETAILS (II) UJ <br />S-6 STEM WALL SECTIONS 0::: - ~CL <br />> (V) wO::: <br /> STRUCTURAL NOTES & zO <br />S-7 0 zO <br /> HANGER INFORMATION I- 0 <(I.J..J <br /> 2~ <br /> I- 0 W >-0 <br />S-7A STRUCTURAL NOTES & (/) ZI <br /> N 0 <((/) <br /> Z :J <br /> HANGER INFORMATION UJ ?;~ <br /> WINDOW & DOOR DETAilS UJ 0 I- 00 <br />S-8 0::: 0 ~B: <br />S-8.1 ROOF INSTALLATION DET > c::: :JI- <br /> oz <br />() Z OI.J..J <br />S-8.1A ROOF INSTALLATION DET 0 ~(/') <br />Z CLZz <br />S-9M MILESTONE WINDOW DET. I- I.J..JOO <br /> LL 0:::0_ <br /> - ~ :r: wz~ <br />S-10M MilESTONE SGD DET. >< COI.J..J~ <br /> "'0 <9 I-~O <br />S-11 STD. GARAGE DETAILS w 0 0-<( <br />~ zO:::o <br /> ~ 0::: >-~- <br />SFPA Fl PRODUCT APPROVAL <x: <(I.J..JD::: <br /> ~ 2I9 <br /> ~ z >- zl-u.. <br /> 0... :)I-....J <br /> ~ () Z :J<( <br /> 0.00::: <br /> :3 0 (/)II- <br /> NOTICE TO BUILDER _1-2 <br /> 0 0 0... 0 I-W <br /> I-~O <br /> I -' HEET NO. a. <br /> iT IS THE INTENT OF THIS DESIGNER THAT N 0::: <br /> 0 <br /> THESE PLAJ\iS ARE ACCURATE AND ARE CO 0 <br /> CLEAR ENOUGH FOR THE LICENSED PROFESS- L.() W <br /> A 2 <br /> ONAL TO CONSTRUCT THIS PROJECT, 0 <br /> IN THE EVENT THAT SOMETHING IS UNCLEAR I ~ I <br /> I'- (/') <br /> OR NEEDS CLARIFlCATION..STOP..AND CALL :J <br /> ~ li) <br /> THE DESIGNER LISTED IN THIS TITLE PAGE. IT ~ 0 <br /> IS THE RESPONSIBILITY OF THE LICENSED 0 <br /> N <br /> PROFESSIONAL THAT IS CONSTRUCTING THIS ~ I- LAST PLOT DATE @ <br /> PROJECT TO FULLY REVIEW THESE DOCUMENTS April 11, 2005 <br /> BEFORE CONSTRUCTION BEGINS AND ANY AND L.() 0 <br /> ALL CORRECTIONS, IF NEEDED, TO BE MADE COVER SHEET <br /> BEFORE ANY WORK IS DONE. ~ -' <br /> DE#250993 <br />