Laserfiche WebLink
<br /> <br />ow <br /> <br />I <br /> <br /> <br /> <br />2 x TOP PLATE <br /> <br />1/4" MIN. SPACE <br />TRl USP TR 1 W/3 - 8d <br />COMMON NAILS @ EA <br />TRUSS OR BLOCKING <br />(NOTE: (2) 16d TOE NAILS <br />CAN BE USED IN LIEU OF <br />TRl STRAP) <br />2 x STUD @ 24" O.C. MAX. <br /> <br /> <br />, <br />I <br />"" <br />I <br />BLOCKS <br /> 'j <br /> , <br /> <br />PACER <br /> <br /> <br />2 x P.T. PLATE <br /> <br />TYPICAL INTERIOR NON-BEARING <br /> <br /> <br />NOTE: <br />PLATE LENGTHS MUST BE <br />AT LEAST 8'-0" LONG. TYPICAL <br /> <br />-BOTTOM SPLICE <br />OVER STUD <br /> <br />SCALE: N.T.S. <br /> <br />REV. USP 07-28-04 TH <br /> <br />"T" <br /> <br />CORNER <br /> <br />TYPICAL "T" AND CORNER DETAIL <br /> <br /> <br />2- ROWS OF <br />10d @ 4/l OIC <br />MAX. <br />10d @ 8/l OIC <br /> <br />TOP PLATE SPLICE DETAIL <br />SCALE: N.T.S. 5/6/04 <br /> <br />PRE ENGINEERED WD TRUSSES @ 24" O.C. <br />INSULATION BAFFLE <br />BATT OR BLOWN INSULATION MIN. R-19 <br />TRUSS ANCHOR (SEE PLAN) <br />FIBERGLASS SHINGLE <br />ROOFING FELT <br />- APA RATED STRUCTURAL SHEATHING <br />MIN 7/16" FASTENED TO TRUSSES WI <br />8d COMMON WIRE NAILS @ 411 OIC <br />_ _B.9UND_ARIE~~Q1C EDGES & 8" OIC FIELD <br />~ METAL DRIP EDGE <br />- 2" X SUBFASCIA <br />CONT. VENTED ALUM SOFFIT <br />811 X 8" X 16" K.O. LINTEL BLOCK <br />Wll #5 DIA. REBAR & <br />FILLED SOLID WIGROUT <br />PRECAST "U" LINTEL <br />(SEE S/2A FOR LINTEL <br />SIZE & REINFORCEMENT) <br />FILL CELL -1 #5 DIA. REBAR WI GROUT <br />@ ALL LOCATIONS SHOWN ON <br />FOUNDATION & FLOOR PLANS <br />ALUM FRAMED WINDOW WI SCREEN <br />PRECAST CONC SILL <br />8" X 8" X 16" CONC. BLOCK <br />DECORATIVE FINISH <br />FTG. DOWEL #5 DIA. REBAR <br />18" IN CONC. -25" EXTEND (ACI 530) <br />ABOVE SLAB. ALL LOCATIONS <br />SHOWN ON FOUNDATION PLAN <br /> <br /> <br />SCALE: N.T.S. <br /> <br /> 2"x4" P.T. PLATE <br /> 1/2" x 8" ANCHOR <br /> BOLT W/ 2" x 1/8" FLAT 12 <br /> WASHER (TYP) <br />@ @ @ <br />J 32" ~j, 32" J <br /> <br /> <br /> <br /> <br /> <br /> <br />, <br />1/2" CD DRYWALL: <br />3/4" P.T. NAILER <br />1/2" DRYWALL <br />CURTAIN NAILER <br />1 X 4 P.T. @ WINDOWS <br />1 X 8 P.T. @ S.G.D. <br /> <br />REV. 9/03 <br /> <br />P.T. PLATE <br />SCALE: N.T.S. <br /> <br />2 - S.P.F. CONST. GRADE TOP PLATE <br />SPLICE MIN 48" APART <br />(6) NAIL AT BASE 2 ROWS 4" O/C STAGGER <br />W/8d COMMON NAIL <br />@ NAIL AT TOP PLATE 2 ROWS 4/l O/C STAGGER <br />W/8d COMMON NAIL <br />@ NAIL OPENING PERIMETER @ 3" O.C. W/8d <br />COMMON NAIL <br />@ NAIL INT. AT 6" O.C. W/8d COMMON NAIL <br />@ STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. <br />w/8d COMMON NAIL <br />CD NO SPLICE CO) HEADER - NAIL SHEATHING TO <br />HEADER W/8'd COMMON NAIL@ 4" ole <br />2x4 P.T. BASE PLATE <br /> <br />-11- If -II <br />" " " <br />" " II <br />" " II <br /> <br />MARBLE STOOL <br />1 X 2 P.T FURRING <br />R-3 FOIL INSUL ON EXT <br />BLOCK WALLS <br />1 X 4 P.T. BASE NAILER <br />WOOD BASE <br />3 1/2" CONe SLAB <br />6 X 6 10/10 W.W.M~ ~ <br />6 MIL VISQUEEN \~ <br /> <br /> <br />TREATED- <br />CLEAN FILL <br /> <br />WALL SHEATHING INSTALL. 8( NAILING SCHED. <br />NO SCALE REV. 5/12/04 <br /> <br /> <br />TYPICAL WALL SECTION <br />CONCRETE BLOCK REV. (STEM) 1/18/05 TH <br /> <br />I I <br />'V TRUSS/JOIST/RAFTER <br />1 1 <br />1 1 <br />~--- -------'--1 <br />1 1 (1) USP RT16T <br />: w/7-10d x 1 1/2" TO BOTH <br />__L_ TRUSS AND DBL. TOP PLATE <br />2 - 2x4 TOP PLATE <br />CONST. GRADE SPF <br />USP SPT 24 w/6-10d <br />TO STUD & TO TOP PLATE <br /> <br />2x4 SPF STUDS @ 16" O.C. <br /> <br /> <br /> <br />1 1 <br />1 1 , <br />:: " TRUSS/RAFTER <br /> <br />~II , <br />: 1 ,,/ ,,/" USP H1W20 W/24-10d x 1 1/2. <br />1 ' ,,' TO BOTH TRUSS <br />__L_ ~ AND DBL. TOP PLATEJSTUD <br />--------- 2 - 2x4 TOP PLATE <br />CONST. GRADE SPF <br />USP SPT24 W/6-10d TO <br />STUD & TO TOP PLATE <br />2x4 SPF STUDS @ 16" O,C. <br /> <br /> <br />A <br /> <br /> <br />USP SPT 22 wi 4 -10d TO <br />STUD & 4-10d TO BASE PLATE <br />1/2" x 8" A307 A.B. OR 5/8"x 7" <br />WEDGE ANCH. w/2" WASHER 6" <br />FROM ENDS & JOINTS & @32" O.C, <br />MIN"w/#3 PT PLATE <br /> <br />A <br /> <br />USP SPT22 W/4-10d TO <br />STUD & 4-10d TO BASE PLATE <br />#3 PT PLATE W/1/2" x 8" A307 A.B. OR 1/2. dia. x 6" <br />TITEN H,D. @ 6" FROM CORNERS & JOINTS & @ 32" O.C. <br /> <br /> <br />1 1 <br />1--------, ' r--------., <br />, II / <br />, '- - - -~- - - -' / <br /> <br /> <br />I <br />..1 <br />1 <br />1 <br /> <br />SEE F~OOR PLAN <br /> <br />SEE FND PLAN <br />FOR FOOTING <br />SIZE AND REINF. <br /> <br />SEE FND PLAN FO <br />FOOTING SIZE AND <br />REINF. <br /> <br />INTERIOR BEARING <br />w/UPLlFT <br /> <br />L <br /> <br />INTERIOR BEARING <br />w/UPLlFT @ 4" STEP-DOWN <br /> <br />NO SCALE REV. 9/24/04 TH <br />THIS DETAIL REQUIRED ONLY WHEN & WHERE <br />SPECIFICALLY INDICATED BY THIS SYMBOL <br />UPLIFT VALUES - (DOUBLE SIDE CONNECTORS-DOUBLES VALUE BELOW) <br />1 (EACH CONNECTOR) EACH STUD -1075 LBS. PER TRUSS <br />UPLIFT CAP 410 PLF (ANCHOR BOLTS) <br /> <br /> <br /> <br />NO SCALE REV. 09/13/04 TH <br />THIS DETAIL REQUIRED ONLY WHEN & WHERE <br />SPECIFICALLY INDICATED BY THIS SYMBOL <br />UPLIFT VALUES - (DOUBLE SIDE CONNECTORS-DOUBLES VALUE BELOW) <br />1 (EACH CONNECTOR) EACH STUD - 462 PLF <br /> <br />SEE FND. PLAN FOR <br />FOOTING SIZE AND <br />REINF. <br /> <br />SCALE: N.T.S. <br /> <br /> <br />TRUSSES <br /> <br />USP RT 16 <br />@ 16" O.C. <br /> <br />----- <br />----- <br /> <br /> <br />2 - 2x4 CONST. GR. SP <br />TOP PLATE. SPLICE <br />24" APART MIN. <br /> <br /> <br />-------------.. <br />, <br /> <br />I <br />II <br />, 1 <br />',~ <br />\...--------------- <br /> <br /> <br />SEE FND PLAN F <br />FOOTI~:G SIZE AND <br />RE1NF. <br /> <br /> UPLIFT CONNECTION CROSS-REFERENCE <br />USP STRUCTURAL CONNECTORS SIMPSON STRONG-TIE <br /> UPLIFT LATERAL FASTENERS CONNECTOR UPLIFT LATERAL FASTENERS <br />CONNECTOR CAPACITY CAPACITY CAPACITY CAPACITY <br /> MASONRY APPLICATIONS MASONRY APPLICATIONS <br />HTA16 1500 590 13-10d x 11/2" META16 1450 335 7-10d x 11/2" <br />HTA20 1500 590 13-10d x 11/2" META20 1450 335 7-10d x 11/2" <br />HTT16 4290* - 18-16d HTT16 4175* - 18-16d <br />HTT22 5370* - 32-16d HTT22 5260* - 32-16d Sinkers <br />LUGT2 1850 - 16-10d & 5-1~4"X3" LGT2 2150 16-16d Sinkers & 7- <br />Wedge bol s - 1/4"x2 1/4" Titen <br />L TS19 1390* - 8-10d L TT19 1350* - 8-16d Sinkers <br />L TTI31 2650* - 18-10d x 11/2" L TTI31 2310* - 18-10d x 11/2" <br /> FRAME APPLICATIONS FRAME APPLICATIONS <br />RT7 585 170 10-8d x 1 1 2" H2.5 415 150 10-8d x 11/2" <br />RT16 1030 645 16-8d x 1 1 2" Hl0 990 525 16-8d x 11/2" <br />RT16-2 1030 390 16-8d x 1 1 2" Hl0-2 760 395 12-10d <br />SPT22 715 260 8-10d SPl 585 - 10-10d <br />SPT24 1075 260 12-10d SP2 1065 - 12-10d <br />SPT4 885 - 6-10d x 11/2" SP4 885 - 6-10d x 11/2" <br />SPTH4 1730 - 12-10d x 11/2" SPH4 1360 - 12-10d x 1 1/2" <br />MUGT15 3965 - 22-10d MGT 3965 - 22-10d <br />LUGT2 2260 - 32-10d LGT2 2050 - 30-16d Sinkers <br />HTW20 1530 95 20-10d HTS20 1450 - 20-10d <br />MSTA18 1275 - 14-10d LSTA18 1165 - 14-10d <br />MST A24 1305 - 18-10d LSTA24 1235 - 18-10d <br />MSTA30 1635 - 22-10d LSTA30 1640 - 22-10d <br />MSTA36 1635 - 22-10d LSTA36 1640 - 24-10d <br /> HUNG APPLICATIONS HUNG APPLICATIONS <br />HUS26 1925 - 20-16d HUS26 1550 - 20-16d <br />THDH26-2 2605 - 30-16d HGUS26-2 2325 - 28-16d <br />HUS28 2570 - 30-16d HUS28 2000 - 30-16d <br />THDH210-2 3970 - 58-16d HGUS28-2 3220 - 48-16d <br /> <br />* CAPACITY IS BASED ON CONCRETE EMBEDMENT, REFER TO MANUFACTURER FOR GROUT FILLED <br />CMU <br />NOTES : <br />1) CONNECTOR CAPACITIES ARE FOR SYP, REFER TO MANUFACTURERS FOR ADDITIONAL <br />INFORMATION <br />2) DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH <br />COULD FORCE THE PLATE OFF THE TRUSS. <br /> <br />3-12d EA. END <br />OF BLOCKING <br /> <br />- - -- <br />- - -- <br /> <br />STRUCTURAL SHEATHING <br />(MIN. 7/16"). NAIL 3" O.C. <br />EDGES STAGGERED, & 6" O.C. <br />INTERIOR. <br /> <br />#3 PT PLATE WI 1/2" X 8" A307 A.B, <br />OR 1/2" dia. X 6" TITTEN H.D. @ 6" <br />FROM CORNERS & JOINTS @ 32" O.C. <br /> <br />SEE P N FOR DIM. <br /> <br /> <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE <br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE <br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND <br />GUST, EXPOSURE "B" WIND ZONE (2001 EDITION). <br /> <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED, <br /> <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS <br />DRAWING ONLY. <br /> <br />INTERIOR SHEARWALL @ TRUSSES <br />STEP-DOWN, WALL TO TRUSS <br /> <br />NO SCALE REV. 9/03 <br />THIS DETAIL REQUIRED ONLY WHEN & WHERE <br />SPECIFICALLY INDICATED BY THIS SYMBOL <br />SHEAR CAP. 260#lIN.FT. <br /> <br />en <br />o <br />ON' ~ <br />--.J f'.- 00 L.L. (:) '. <br />--.J 111 ffi 0 CJJ 0 <br />~O) ~a~ <br />,111 ffi:5:!E <br /><:t:oq C-(/)I <br />0<.0 ~:J:~ <br />O::M'" c...~c... <br />0..-1 S;;: 0 SQ <br />u:~ Q~~ <br />I I ,~ :J <br />::r:X ~:Jo <br />O<:t: I-UcU <br />u.: lJ.J LJ.J t:::! <br />l5 0:: I cr: <br />co ~I-O <br />(/)0 :r: <br />O<.OOOzZI- <br />-l<.Ooq~~~ <br />O-l 0..-10) Vi ~ z <br />111 lJ.J..J ::J <br />9;.I11No .0:: <br />-oq o~o <br />,<.O<:t:zzz <br />O~O~~o <br />0(") ~:J:jf= <br />oq..-1 zzU <br />(")~ 3~5 <br />X I ~~ ~ <br />o UJ 0:: c... <br />COz oglJ.J <br />. 0 lJ.J(/) 0:: <br />O::r: t3z>- <br />n.: D.. ~ (3 ~ <br />(0 <br /> <br />o <br />Z <br />00:: <br />OW <br />r.J)w <br />zZ <br /><t:(!) <br />Clz <br />UJ <br /> <br />lD CX) N <br />'<t LO N <br />N I'- ...-1 <br />'<t 0) 0 <br />(Y) '<t to <br />W UJ lJ.J <br />ll.. ll.. ll.. <br /> <br />'e.D <br />Q) <br />.0 <br />C <br />~ C .c <br />..... 0 c <br />~ (J) >, <br />C ::J <br />c:( ~ :c <br />Q) ~ :i <br />::J <br />E .S;; ~ <br /> <br />fu6 <br /> <br />~ <br /> <br /> <br />o <br />. <br />~ <br />z <br />o <br />C/) <br />0:: <br />W <br />> <br /> <br />(") <br />o <br />o <br />~ C/) <br />N Z <br />~ 0 <br />~ C/) <br />~ > <br />o W <br />UJ 0:: <br />:::J <br />CJ) <br />~ <br /> <br />-l <br />-l <br />~ <br />2 <br />UJ <br />I- <br />CJ) <br />111 <br />o <br />o <br /><;-I <br />oq <br />~ <br />o <br /> <br />lJ.J <br />:;:;;; cr: <br />W w 15 ~ 2 <br />O ~ LJ.J I- <br />:;:;;; 0 :;:;;; z <br />X Vi 0 ::J <br />I- o~a:8 <br />o a:: 0 z U <br />Z 5:~lJ.J~ <br />~ 0 ~ 5 <br />W 5!EE~z <br />,n <l: z 0:: 8 <br />....., 0 LJ.J ~ <br /><t: LJ.J~(/)O <br />I- 5~6~ <br />O ::JClJViCJJ <br />0' Cl:: z ~ <br />o (/) <l: LJ.J ~ <br />u.~~~L.L. <br />W ~20o <br />o (/) ex: I- <br />0::21526 <br />_ :;:;;; ex: 0 <br />........ LJ.J _ lJ.J..J <br />::) ~0S;;:!l:l <br />~::J..J -a:: <br />....., ~ ~ :3 ~ <br />C/) ..JlJ.J;iO <br />;i~3~ <br /> <br /> <br />o <br />oq <br />..- <br />..- <br />I <br />0) <br />o <br />(,Of'.- <br />C"")f'.- <br />C"")N <br />-lU{ <br />l.l..0) <br />_(,0 <br /><(f'.- <br />Cl..' <br />~~ <br /><(co <br />1-...'- <br /> <br /> z <br /> 0, <br /> -0 <br /> ~> <br /> >-l <br /> -co <br /> Ow <br /> ~~ <br /> -0 <br /> ~I <br /> Oct) <br /> -ll- <br /> l.l..ct) <br /> -lWO <br /> ~~g <br /> I-ZW <br /> zot: <br /> Wo::J <br /> U(,Oct) <br /> en <br /> ...J <br /> ...J <br /> - <br /> :c <br />>- $ (Y) <br />w --. 0 Cl:: 0.: <br />r.J) w Cl:: <br />a:: - 0 L.I..J zO <br />> --.J zU <br /> ~w <br />0 ~ N 0 ~~ <br />...- >-0 <br />...- W z :c <br />en 0 I- ~ CI) <br />Cl ::J <br /> Z <br />Z 0 - ~ <br />lJJ --.J c:: 00 <br />W --.J WCl:: <br />a:: ~ z ULL <br /> 0 ::J I- <br />> o Z <br />() LL I- OLJ.J <br /> W Cl:: (J) <br />Z ~ >< :r: fu6z <br /> W ~ Cl::uQ <br />- ~ I- 0 CJ wzS:2 <br /> r.J) ~ c:lw~ <br />~O 1-1=0 <br />-..- Z o_~ <br /> a::: z Cl:: 0 <br />~ >-$:- <br /> ~w6 <br />~~ z >- ~:C..J <br /> ~ 0.. zl-ll.. <br />~ () :)I-..J <br /> ....J 0 c-g~ <br />0 0 (/):c~ <br /> a.. 0 I t: w <br />I ...J I-$:U <br />C\I <br />CO C/) SHEET NO. D.. <br />LO a:: <br /> Z 0 <br /> 8-6 (8) 0 <br />I ~ 0 UJ <br />I'- I- 2 <br />~ ~ 0 0 <br /> ::r: <br />UJ CJ) <br />~ ...-C/) :::J <br /> 111 <br />LO O~ 0 <br /> 0 <br /> N <br />-n --13 LAST PLOT @ <br />DATE: April 11, 2005 <br /> <br />NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REYIE-W ALL <br />DRAWiNGS BEFORE CONSTRUCTION BEGINS, DANSCO <br />ENGINEERING, LLC is RESPONSIBLE FOR THE STRUCTURAL <br />INTEGR,TY OF THIS PROJECT ONLY. ANY DiSCREPANCY BETWEEN <br />FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWI~GS, <br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED <br />DRAWI~GS MUST BE BROUGHT TO THE AT1ENTION OF DANSCO <br />ENGINEERING, LLC PRIOR TO THE COMMENCEMENT OF CO"STRUCT10N, <br /> <br />- ----- <br /> <br />" <br />,- <br />,- <br />/ <br />/ <br />/ <br />I <br />I <br />I <br />I <br />, <br />I <br />I <br />I <br />\ <br />\ <br />\ <br />\ <br />, <br />, <br />, <br />, <br />, <br />, <br />, <br /> <br /> <br />, <br />, <br />, <br />, <br />, <br />, <br />, <br />\ <br />\ <br />\ <br />\ <br />\ <br />I <br />, <br />I <br />I <br />I <br />I <br />I <br />/ <br />, <br />/ <br />";,,,,/ <br /> <br />.V\ <br /> <br />~11LOOl <br /> <br />------.... <br /> <br />PLACE SEAL HERE DE #250993 <br />