Laserfiche WebLink
<br />TERMITE SPECIFICATIONS: <br /> <br />1. A PERMANENT SIGN WHiCH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DiSCHARGE AT LEAST 1'-0" <br />AWAY FROM BUiLDING SIDE WALKS.(FBC 1503.4.4) <br /> <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RiSERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 iNCHES, <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINiSH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br /> <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE,(FBC 1816.1,1) <br /> <br />6. SOIL DiSTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED.(FBC 1816,1,2) <br /> <br />7. BOXED AREAS iN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAII\FALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT is <br />REQUIRED.(FBC 1816.1.4) <br /> <br />9, CONCRETE OVERPOUR AND MORTAR ALOI\G THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816,1.5) <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS,(FBC 1816.1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE iNCLUDING LANDSCAPING AND IRRIGATION, ANY SOIL DiSTURBED AFTER <br />THE VERTICAL BARRIER is APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-COI'<STRUCTION TREATMENT.(FBC 1816.1.7) <br /> <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES, THE TREATMENT is IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. "(FBC 1816.1.7) <br /> <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL, <br />(FBC 2303.1.3) <br /> <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303,1.4) <br /> <br />~ <br /> <br />A.B. <br />Abv. <br />A/C <br />Adj. <br />A,F.F. <br />A,H,U. <br />ALT. <br />B.C. <br />B.F. <br />Bk Sh <br />Bm. <br />BOT. <br />B.P. <br />Brg. <br />Cir. <br />Clg. <br />Col. <br />Compo <br />C.T. <br />D <br />Dec. <br />Ded, <br />Dbl. <br />Dia. <br />Disp. <br />Dist. <br />D.S. <br />D.V. <br />DW. <br />Ea. <br />E.W, <br />Elec. <br />Elev. <br />Ext. <br />Exp. <br /> <br />ABBREVIA TIONS <br /> <br />Anchor Bolt <br />Above <br />Air-Conditioner <br />Adjustable <br />Above Finished Floor <br />Air Handler Unit <br />Alternate <br />Base Cabinet <br />Bifold Door <br />Book Shelf <br />Beam <br />Bottom <br />Bypass door <br />Bearing <br />Circle <br />Ceiling <br />Column <br />A/C Compressor <br />Ceramic Tile <br />Dryer <br />Decorative <br />Dedicated Outlet <br />Double <br />Diameter <br />Disposal <br />Distance <br />Drawer Stack <br />Dryer Vent <br />Dishwasher <br />Each <br />Each Way <br />Electrical <br />Elevation <br />Exterior <br />Expansion <br /> <br />F.B.C. <br />Fin. Fir. <br />F.G. <br />Fir. <br />Fdn. <br />Fir. Sys, <br />F,PI. <br />Ft. <br />Ftg. <br />FX <br />Galv. <br />G.C. <br />G.F,I. <br />G.T. <br />Hdr. <br />Hgt. <br />HB <br />Int. <br />K/Wall <br />K.S. <br />Laun. <br />Lav, <br />L.F. <br />L.T. <br />Mas. <br />Max <br />M.C, <br />Mfgr. <br />Micro. <br />Min <br />M.L, <br />Mir. <br />Mono <br />N.T.S. <br /> <br />Florida Bldg. Code <br />Finished Floor <br />Fixed Glass <br />Floor <br />Foundation <br />Floor System <br />Fireplace <br />Foot / Feet <br />Footing <br />Fixed <br />Galvanized <br />General Contractor <br />Ground Fault Interrupter <br />Girder Truss <br />Header <br />Height <br />Hose Bibb <br />Interior <br />Kneewall <br />Knee Space <br />Laundry <br />Lavatory <br />Linear Ft. <br />Laundry Tub <br />Masonry <br />Maximum <br />Medicine Cabinet <br />Manufacturer <br />Microwave <br />Minimum <br />Microlam <br />Mirror <br />Monolithic <br />Not to Scale <br /> <br />Opn'g. <br />Opt. <br />Pc. <br />Ped. <br />P.L. <br />PLF <br />PIt. Ht. <br />Pit Sh. <br />PSF <br />P.T. <br />Pwd. <br />Rad. <br />Ref. <br />Req'd. <br />Rm. <br />Rnd. <br />R/SH <br />SD. <br />S,F. <br />Sh. <br />SHT <br />S,L. <br />S.P,F. <br />Sq. <br />S.Y,P. <br />Temp. <br />Thik'n. <br />T.O,B. <br />T.O,M. <br />T.O,P, <br />Trans. <br />Typ. <br />UCL <br />UNO. <br />VB <br />Vert. <br />V,L. <br />VTR <br />W <br />WI <br />W/C <br />W.A. <br />Wd <br />WP <br /> <br />MASTER REVISIONS <br /> <br />DATE <br /> <br />DESCRIPTION <br /> <br />Opening <br />Optional <br />Piece <br />Pedestal <br />Parallam <br />Pounds per linear foot <br />Plate Height <br />Plant Shelf <br />Pounds per square foot <br />Pressure Treated <br />Powder Room <br />Radius <br />Refrigerator <br />Required <br />Room <br />Round <br />Rod and Shelf <br />Smoke Detector <br />Square Ft. <br />Shelves <br />Sheet <br />Side Lights <br />Spruce Pine Fir <br />Square <br />Southern Yellow Pine <br />Tempered <br />Th icken <br />Top of Block <br />Top of Masonry <br />Top of Plate <br />Transom Window <br />Typical <br />Under Cabinet Lighting <br />Unless Noted Otherwise <br />Vanity Base <br />Vertical <br />Versalam <br />Vent through Roof <br />Washer <br />With <br />Water Closet <br />Wedge Anchor <br />Wood <br />Water Proof <br /> <br />STRUCTURAL NOTES: <br /> <br />STRUCTURAL DESIGN CRITERIA <br /> <br />FOUNDATIONS <br /> <br />3. ANY WOOD FRAME iNTERIOR BEARING WALL STUDS THAT <br />HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. <br />SHALL HAVE STUD PROTECTION <br />SHIELDS FOR ALL HOLES OVER 1" IN DIA. <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WiTH <br />SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br /> <br />CODES: <br /> <br />FLORIDA BUILDING CODE, 2001 EDITION WITH 2003 REViSIONS <br />BUiLDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-02) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br /> <br />FOUNDATION INSPECTIONS <br /> <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDI~G <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRETCHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AI\D HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40, <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DiSCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS, <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVI DED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />11/2" TO FORM <br /> <br />WOOD FRAMING INSPECTION <br /> <br />LIVE LOADS: <br /> <br />ROOF <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />ST Al RS <br />LIGHT PARTITIONS (DEAD LOAD), U.N.O. <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606,2. <br />WII\D VELOCITY: 123 M.P.H., USE FACTOR: 1.0 <br /> <br />20 PSF (REDUCIBLE) <br />40 PSF <br />40 PSF <br />40 PSF <br />20 PSF <br />10 PSF ATTIC l.L. <br /> <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, I~SPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION, <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />1, ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS, <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3, TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE FOLLOWING <br />DESIGN LOADS: <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION, <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGiSTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMiNE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />WIND lOADS: <br />(F.B.C.) <br /> <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />3000 PSI <br />3000 PSI <br /> <br />REINFORCING: <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCING BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />ASTM C90-99b, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MORTAR TYPE "S" 1800 PSI <br />CONCRETE GROUT 3000 PSI <br />CO,'HINUOUS MASONRY INSPECTION is REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL AI\D MiSCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETC. UNO. <br />~O. 2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB <br />FLOOR SHEATHING: T&G A-C GROUP 1 APA RATED (48/24) <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.0E) <br />WOOD COLS. PARALLAM 2.0E U,N,O. <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE LOAD: 20 PSF <br />TOP CHORD DEAD LOAD: 10 PSF <br /> <br />STRUCTURAL <br />STEel: <br /> <br />REINFORCING STEEL <br /> <br />ALL REINFORCING STEEL SHALL BE NEW DEFORMED BARS <br />FREE FROM RUST, SCALE & OIL & SHALL MEET ASTM A-615 <br />REINFORCING FOR FOOTING SHALL BE SUPPORTED ON PRE- <br />CAST CONCRETE PADS, TOP REINFORCING SHALL BE <br />POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. <br />DOWELS FOR COLUMNS & FILLED CELLS SHALL BE SECURED <br />IN PLACE BY USiNG ADDITIONAL CROSS- REINFORCING TIED <br />TO FOOTING REINFORCING, SPLICES IN REINFORCI,'\G WHERE <br />PERMITTED SHALL BE THE FOLLOWING MINIMUM, UNLESS <br />OTHERWISE INDICATED ON THE DRAWINGS: <br /> <br />FTGS, WALLS, COLUMNS, BEAMS, SLABS: 36 DIA. OR 2'-0" MIN., WHICHEVER IS MORE. <br />FILLED CELL REINFORCING: 40 DIA. OR 2'-0" MIN., WHiCHEVER is MORE. <br />TEMPERATURE REII\FORCING: 20 DIA, OR 1'-0" MIN., WHICHEVER is MORE, <br />WELDED WIRE MESH: 8" LAP <br /> <br />WOOD FRAMING: <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />BOTTOM CHORD DEAD LOAD: <br /> <br />10 PSF <br />40 PSF <br /> <br />10 PSF <br /> <br />BOTTOM CHORD ATTIC LIVE LOAD: <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED lOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 5 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD lOAD. <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br />MASONRY WALL CONST. <br />1. HOLLOW LOAD BEARiNG UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI ( f'm = 1500 PSI) <br />2. MORTAR SHALL BE TYPE "S", CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5, VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS, REiNFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWISE NOTED, <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DIAMETERS, U,'\LESS OTHERWISE NOTED ON THE DRAWINGS <br />7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC <br />SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO <br />PREVENT THE FLOW GROUT INTO CELLS BELOW. THE USE OF FELT <br />PAPER AS A STOP is PROHIBITED. <br /> <br />UPLIFT CONNECTORS <br /> <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AI\D ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERiNG FOR THE LOCATION OF THESE WALLS. <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />15 PSF <br />50 PSF <br />65 PSF <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE E~GINEER PRIOR TO <br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />BUILDING DATA <br /> <br />CONSTRUCTION TYPE - TYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br />MEAN ROOF 15 n. HIGH <br />TYPICAL FOR SINGLE HOMES. <br /> <br />WIND SPEED 123 MPH (3 SEC. GUST) <br />WIND IMPORTANCE FACTOR - (Iw) = 1.0 <br />WIND EXPOSURE - "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +i- 0.55 (PARTIALLY <br />ENCLOSED BLDG) <br /> <br />WOOD CONSTRUCTION <br /> <br />1, WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", LATEST EDITION. <br />2, ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E. BLOCKING OR GABLE END BRACING) SHALL BE EITHER <br />SOUTHERN PINE, OR S,P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br /> <br />DESIGN WIND PRESSURE: <br /> <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br />WINDOWS AND DOORS <br />123 MPH + 38 PSF 1- 40 PSF <br /> <br />GARAGE DOORS (V = 123 MPH) <br />SINGLE 9x7 +37.0 PSF I -40.0 PSF <br />DOUBLE 16x7 +37.0 PSF / -41.0 PSF <br /> <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br /> <br />ALL WORK SHALL COMPLY WlTH ALL <br />PREVAILING CODES, FLORIDABUlLDil':O <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYRHILLS ORDINANCES <br /> <br /> <br />ENGINEERED PLANS <br />ON FILE <br /> <br />REVIEWED <br />MAY 1 02005 <br /> <br />~i5wr <br /> <br />BRISTOL GRANDE 2003 <br /> <br />GENERAL NOTES: <br /> <br />THE FOLLOWING TECHINCAL CODES <br />SHALL APPLY: <br />2001 FLORIDA BUILDING CODE, <br />WITH 2003 REVISIONS <br />PLUMBIr-..G , MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />AND NFPA 70-02 NATIONAL ELECTRICAL CODES <br /> <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WALL MOUNT WATER CLOSET VOLUME <br />3.5 GALLONS <br />3. WATER - FLOW RATE. <br />PUBLIC FACILITIES 0.5 G.P,M, <br />PRIVATE FACILITIES 2,2 G.P.M. <br />SHOWER HEADS 2.5 G.P.M; <br />4. ALL WATER L1I\E PLUMBING <br />TO BE PVPC <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBC, <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />o HANDRAILS - SECTION 1007.5 <br />o GUARDRAILS - SECTION 1015, 1019.9 <br />o STAIRS - SECTION 1007 <br />o CHIMI\EY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />o EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />5, ALL OPENIr-..GS SHALL COMPLY WITH <br />2001 FBC WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AI\D O.H. GARAGE DOORS ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br /> <br />6, ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />7. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS, <br />(SECTION 2405.2) <br /> <br />INDEX OF DRAWINGS <br /> <br />SHT NO: <br /> <br />TITLE <br /> <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />S-1 <br />S-2 <br />S-3 <br />S-4 <br />S-5 <br />S-6 <br />S-7 <br /> <br />COVER SHEET <br />FLOOR PLAN <br />FOUNDATION PLAN <br />ELECTRICAL PLAN <br />ELEVATIONS <br />TRUSS LAYOUT <br />MASONRY DETAILS <br />LINTEL PLAN AND DETAILS <br />DETAILS <br />DETAILS <br />DET AI LS <br />DETAILS <br />STRUC. NOTES & <br />HANGER INFORMATION <br />DET AI LS <br />DOOR DETAILS <br />ROOFING DETAILS <br />ROOFING DETAILS <br />GARAGE DETAILS <br />DETAILS <br />PRODUCT APPROVAL <br />WINDOW DETAILS <br />SGD DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br /> <br />S-8 <br />S-9 <br />S-10 <br />S-10A <br />S-11 <br />S-12 <br />S-13 <br />S-14 <br />S-15 <br />S-16 <br />S-17 <br />S-18 <br /> <br />NOTICE TO BUILDER <br /> <br />IT IS THE INTENT OF THIS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT. <br />IN THE EVENT THAT SOMETHING is UNCLEAR <br />OR NEEDS CLARIFICATION..STOP..AND CALL <br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT <br />IS THE RESPONSIBILITY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />BEFORE ANY WORK IS DONE. <br /> <br />W <br />ll..~0:: <br />'00::0 <br />w ll..ll.. <br />~W""f- <br />~90S <br />W x~o::o <br />() O::::lll..u <br />I- o::ozU <br />Q..""w<t <br />O Q..""'~f- <br /><to<to <br />Z wO::f-z <br />O::ll..w <br />W <tzo::O <br />,~ ow<to <br />\"J W~(/)o <br />1-<( of-;:: z z <br />oct <br />O ::::lW-w <br />cyo::(/)"" <br /><t Z "'" . <br />o ~(/)w<tz <br />LL <.::lZ~S:O <br />W ;::QOof= <br />O(/)O::f-CS <br />a::: orEO~::J <br />- ll.. o::uo.. <br />"""'- w~woo.. <br />::) O::Of-ffi<t <br /><y <t-lz -I <br />::::l-l-.O::-I <br />(j) CY <t (/) 0 <t:~ <br />(/)0::-1........ <br />-Iw-lo <br />-I>~zO:: <br /><to::> <t 0 <br /> <br />en <br />Q,)Q)-I <br />(l)1Q~ <br />~-u ~ <br />~ ~ ~ <br />I en 0 <br />(I)<u8: <br />Q,)c8 <br />- '0.0 u:: <br />(0-- - <br />...en~ <br />OQ)w <br />e"Cu <br /> <br />~(lI <br />~c=JO <br />~<(CO <br /> <br />(/) <br />w <br />o <br /><.::l <br />Z <br />o <br />-I <br />::::l <br />co <br /> <br /> <br />w <.::l co 0 <br />I ~ N Z <br />f-.(/) ~ l,l) <br /><.::lZw <l:;l,l)..-l ~ <br />(/)~Qo O::Nl,l) en <br />. of-O o..-l~ Z <br />ffiz<tu w~11:ii 0 <br />w;::~<.::l II~. i= <br />~(/)-z f-f-..JI.LJ :J <br /><.::lO::UO 0::ll..L.L.Q. ..J <br />zWf5:-I 00.. 0 <br />wo(/)s(/)ll..z~ffi en <br />wZ(/)cnZOO .0 Z <br />I::::lZwQ::Jf=ZC:: <br />f- 0 c:r I (/) <t 0:: :I:::J CJ <br />Oll..z...JQ..f-;>wOolXl u; <br /><t w (/) Q.. a: . IJJ <br />f-w-lIo:: -1--- <br />(/) <t f- 0.- .....J C <br />w<.::l0::3MZo:: 'I.LJ <br />coO:::) o<t::::lc(c( < <br />w::Jf->-oOf-..JX C <br />I>Uo:NWUa:o ::;::: <br />f-O::>::::l""IZ::::lc(;::: 0.... <br />O::""'f-<.::lO::oo::: <br />2~tJ;83U5tJ;DD ii <br /> <br />-I <br /><t <br />0:: <br />f- <br />~ <br />o <br />(/) <br />(/) w <br />o U <br />-IMU::X <br />COo ll..<t <br />wI"-- Oll.. <br /><.::l N M <:t <br />zM MO <br /><t...J (Y) (Y) <br />O::ll..NN <br />o .. I I <br />. ~ ~~ <br />(/) Q.. 00 00 <br />11')0 r-:..r-:.. <br /><:t Q.. 0 0 <br />m <l:; <:t <:t <br /> <br /> <br />z <br />o <br /> <br />...: <br />f- <br />E 11') <br />o 0 <br />III 0 <br />III - N <br />O(Y) - <br />Q50~ ~ <br />Q)I"--......,w .c <br />1:\DNN U <br />~:<t~~ Co <br />Oll..""",O::<t......, ~ <br />. co' ~ ~ ~ ~ <br />(/)~ou~......, <br />Cl.<:t::::lf-m w <br />u:; 8.I g: ffi 0 ~ <br />Q) <t Q.. (/) U Z 0 <br /> <br />C\JU) <br />Lriz <br />'0 <br />C\J- <br />~U) <br />> <br />w <br />0:: <br /> <br />z <br />o <br />U5 <br />-11') <br />>0 <br />w........ <br />0::0 <br />U......, <br />f-........ <br /><t(Y) <br />~Q.. <br />1"--0 <br />M........ <br />......,0 <br />'~ <br />:B~ <br /> <br />() <br />() <br />~ <br />Q) <br />--t-J <br />.- <br /> <br />Z~ ~ <br />() .= <br />--0 I <br />U):>(Jl <br />>- () <br />-(11~ <br />OQ)(i) <br />'<{L(i) <br />(L~ 1L <br />r ~ l\l <br />'<{($){L <br />f- Q) E <br />3 l\l <br />f- <br /> <br /> <br /> <br />. <br />Z <br />o <br />() <br />~ <br /> <br />o <br />z W <br />(.:;l Z <br />(/i~S2 0 <br />Wf-(/)W:::i <br />OZ(/):::!<( <br />oo-:r:> <br />z:2t:s:(/) <br /><(NWC!:~ <br />(.:;ld.~O 0 <br />~C!:CloO <br />s:owwU <br /><(LL.:r:...Jf- <br />o::Of-l'5z <br />O:::iC!:(/)~ <br />~~toC!: <br />~~<(~i3 <br /> <br />L() <br />-=:::tOO <br />O-l <br />9-l <br />N- <br />L()I <br />~S <br />~W <br />~- <br />L()> <br />~~ <br />>-W <br />0::0:: <br />aU <br />I-L() <br />z -=:::t 205 <br /> <br />w> I- LAST PLOT DATE <br />a March 10, 2005 <br /> <br />~ -l COVER SHEET <br /> <br />lJJ <br />o <br />z <br /><( <br />O::(Y') <br />00 <br />.....10 <br />ON <br />wJ- <br />~CJ) <br />~C2 <br />zCQ <br />:5 <br />Q.. <br /> <br />SHEET NO. <br /> <br />1 <br /> <br />w ~ <br />0:: <br />() >-ll..z <br />Zf-O <br /><tz- <br />I- zw~ <br />-(/)> <br />Oz- <br />o wo 0 <br />Z ~Ut5 <br />oz- <br />OW 0:: <br />I- o::~g <br />Q..-ll.. <br />:r: ~~~ <br />,~ w W 0:: <br />\"J co I f- <br />f-f-rE <br />Of-u <br />a::: z::::l . <br />>-OQ.. <br />>- <t I 0:: <br />~t:o <br />0.. z~u <br />c:ro::W <br />O ..Jw~ <br />Q..zO <br />U (/)ZI <br />-<(J) <br />2=~::::l <br /> <br />Q.. <br />0:: <br />o <br />U <br />w <br />~ <br />o <br />I <br />(/) <br />:::) <br />(Y) <br />o <br />o <br />N <br /> <br />@ <br />