<br />TERMITE SPECIFICATIONS: <br /> <br />· 1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br /> <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403,1.6) <br /> <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE,(FBC 1816.1.1) <br /> <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED.(FBC 1816.1,2) <br /> <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED.(FBC 1816.1.4) <br /> <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-CONSTRUCTION TREATMENT.(FBC 1816.1.7) <br /> <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816.1.7) <br /> <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br /> <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br /> <br />A,B. <br />Abv. <br />A/C <br />Adj. <br />A.F.F. <br />A.H.U. <br />ALT. <br />B.C. <br />B.F. <br />Bk Sh <br />. Bm. <br />BOT. <br />B.P. <br />, Brg. <br />Cir. <br />Clg. <br />Co!. <br />Compo <br />C.T. <br />D <br />Dec. <br />Ded. <br />Dbl. <br />Dia, <br />Disp. <br />Dist. <br />D.S. <br />D.V. <br />D.w. <br />Ea. <br />E.w. <br />Elec. <br />Elev. <br />Ext. <br />Exp. <br /> <br />.~ <br /> <br />-t <br />~ <br /> <br />ABBREVIATIONS <br /> <br />Anchor Bolt <br />Above <br />Air-Conditioner <br />Adjustable <br />Above Finished Floor <br />Air Handler Unit <br />Alternate <br />Base Cabinet <br />Blfold Door <br />Book Shelf <br />Beam <br />Bottom <br />Bypass door <br />Bearing <br />Circle <br />Ceiling <br />Column <br />A/C Compressor <br />Ceramic Tile <br />Dryer <br />Decorative <br />Dedicated Outlet <br />Double <br />Diameter <br />Disposal <br />Distance <br />Drawer Stack <br />Dryer Vent <br />Dishwasher <br />Each <br />Each Way <br />Electrical <br />Elevation <br />Exterior <br />Expansion <br /> <br />F.B.C. <br />Fin. Fir. <br />F.G. <br />Fir. <br />Fdn. <br />Fir. Sys. <br />F.PI. <br />Ft. <br />Ftg. <br />FX <br />Galv. <br />G.C. <br />G.F.1. <br />G.T. <br />Hdr. <br />Hgt. <br />HB <br />Int. <br />K/Wall <br />K.S. <br />Laun. <br />Lav. <br />L,F. <br />L.T. <br />Mas. <br />Max <br />M.C. <br />Mfgr. <br />Micro. <br />Min <br />M.L. <br />Mir. <br />Mono <br />N.T.S. <br /> <br />Florida Bldg. Code <br />Finished Floor <br />Fixed Glass <br />Floor <br />Foundation <br />Floor System <br />Fireplace <br />Foot / Feet <br />Footing <br />Fixed <br />Galvanized <br />General Contractor <br />Ground Fault Interrupter <br />Girder Truss <br />Header <br />Height <br />Hose Bibb <br />Interior <br />Kneewall <br />Knee Space <br />Laundry <br />Lavatory <br />Linear Ft. <br />Laundry Tub <br />Masonry <br />Maximum <br />Medicine Cabinet <br />Manufacturer <br />Microwave <br />Minimum <br />Microlam <br />Mirror <br />Monolithic <br />Not to Scale <br /> <br />Opn'g. <br />Opt. <br />Pc. <br />Ped. <br />P,L. <br />PLF <br />PIt. Ht. <br />Pit Sh. <br />PSF <br />P.T. <br />Pwd. <br />Rad. <br />Ref. <br />Req'd. <br />Rm. <br />Rnd. <br />R/SH <br />SD. <br />S.F. <br />Sh. <br />SHT <br />S.L. <br />S.P.F. <br />Sq. <br />S.Y.P. <br />Temp. <br />Thik'n. <br />T.O.B. <br />T.O.M. <br />T.O.P. <br />Trans. <br />Typ. <br />UCL <br />U.N.O. <br />VB <br />Vert. <br />V.L. <br />VTR <br />W <br />WI <br />W/C <br />W.A. <br />Wd <br />WP <br /> <br />MASTER REVISIONS <br /> <br />DATE <br /> <br />DESCRIPTION <br /> <br />Opening <br />Optional <br />Piece <br />Pedestal <br />Parallam <br />Pounds per linear foot <br />Plate Height <br />Plant Shelf <br />Pounds per square foot <br />Pressure Treated <br />Powder Room <br />Radius <br />Refrigerator <br />ReqUired <br />Room <br />Round <br />Rod and Shelf <br />Smoke Detector <br />Square Ft. <br />Shelves <br />Sheet <br />Side Lights <br />Spruce Pine Fir <br />Square <br />Southern Yellow Pine <br />Tempered <br />Thicken <br />Top of Block <br />Top of Masonry <br />Top of Plate <br />Transom Window <br />Typical <br />Under Cabinet Lighting <br />Unless Noted Othervvise <br />Vanity Base <br />Vertical <br />Versalam <br />Vent through Roof <br />Washer <br />With <br />Water Closet <br />Wedge Anchor <br />Wood <br />Water Proof <br /> <br />STRUCTURAL NOTES: <br /> <br />STRUCTURAL DESIGN CRITERIA <br /> <br />FOUNDATIONS <br /> <br />3. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT <br />HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. <br />SHALL HAVE STUD PROTECTION <br />SHIELDS FOR ALL HOLES OVER 1" IN DIA. <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH <br />SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br /> <br />CODES: <br /> <br />FLORIDA BUILDING CODE, 2001 EDITION WITH 2003 REVISIONS <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-02) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br /> <br />FOUNDATION INSPECTIONS <br /> <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRETCHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />11/2" TO FORM <br /> <br />WOOD FRAMING INSPECTION <br /> <br />LIVE LOADS: <br /> <br />ROOF <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />ST AI RS <br />LIGHT PARTITIONS (DEAD LOAD), U.N.O. <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606.2. <br />WIND VELOCITY: 123 M.P.H., USE FACTOR: 1.0 <br /> <br />20 PSF (REDUCIBLE) <br />40 PSF <br />40 PSF <br />40 PSF <br />20 PSF <br />10 PSF ATTIC L.L. <br /> <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION. <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER U~LESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE FOLLOWING <br />DESIGN LOADS: <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDAI\CE WITH SPECIFIED LOADS <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS A~D DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIO~S, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMA~ENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />WIND LOADS: <br />(F.B.C.) <br /> <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO I'\OT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />3000 PSI <br />3000 PSI <br /> <br />REINFORCING: <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCING BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />ASTM C90-99b, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MORTAR TYPE "S" 1800 PSI <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL AND MISCELLAI\EOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O. <br />1'\0. 2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB <br />FLOOR SHEATHING: T&G A-C GROUP 1 APA RATED (48/24) <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2,OE) <br />WOOD COLS. PARALLAM 2.0E U.N.O. <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE LOAD: 20 PSF <br />TOP CHORD DEAD LOAD: 10 PSF <br /> <br />STRUCTURAL <br />STEEL: <br /> <br />REINFORCING STEEL <br /> <br />WOOD FRAMING: <br /> <br />ALL REINFORCING STEEL SHALL BE NEW DEFORMED BARS <br />FREE FROM RUST, SCALE & OIL & SHALL MEET ASTM A615 <br />REI~FORCING FOR FOOTING SHALL BE SUPPORTED ON PRE- <br />CAST CONCRETE PADS, TOP REINFORCING SHALL BE <br />POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. <br />DOWELS FOR COLUM~S & FILLED CELLS SHALL BE SECURED <br />IN PLACE BY USING ADDITIONAL CROSS- REINFORCING TIED <br />TO FOOTING REINFORCING. SPLICES IN REI~FORCING WHERE <br />PERMITTED SHALL BE THE FOLLOWING MINIMUM, UNLESS <br />OTHERWISE INDICATED ON THE DRAWINGS: <br /> <br />FTGS, WALLS, COLUMNS, BEAMS, SLABS: 36 DIA. OR 2'-0" MIN., WHICHEVER IS MORE. <br />FILLED CELL REINFORCING: 40 DIA. OR 2'-0" MIN., WHICHEVER IS MORE. <br />TEMPERATURE REINFORCING: 20 DIA. OR 1'-0" MIN., WHICHEVER IS MORE. <br />WELDED WIRE MESH: 8" LAP <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />BOTTOM CHORD DEAD LOAD: <br /> <br />10 PSF <br />40 PSF <br /> <br />10 PSF <br /> <br />BOTTOM CHORD ATTIC LIVE LOAD: <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 5 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br />MASONRY WALL CONST. <br /> <br />1. HOLLOW LOAD BEARI:'\G UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI ( f'm = 1500 PSI) <br />2. MORTAR SHALL BE TYPE "S", CONFORMII\G TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWI~GS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWISE NOTED. <br />6. REINfORCING STEEL SHALL BE LAPPED A MI~IMUM OF 40 BAR <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC <br />SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO <br />PREVENT THE FLOW GROUT INTO CELLS BELOW. THE USE OF FELT <br />PAPER AS A STOP IS PROHIBITED. <br /> <br />UPLIFT CONNECTORS <br /> <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />15 PSF <br />50 PSF <br />65 PSF <br /> <br />,.. <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE E~GINEER PRIOR TO <br />FOU~DATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />BUILDING DATA <br /> <br />CONSTRUCTION TYPE - TYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br />MEAN ROOF 15 FT. HIGH <br />TYPICAL FOR SINGLE HOMES <br /> <br />WIND SPEED 123 MPH (3 SEC. GUST) <br />WIND IMPORTANCE FACTOR - (Iw) = 1.0 <br />WIND EXPOSURE - "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.55 (PARTIALLY <br />ENCLOSED BLDG) <br /> <br />WOOD CONSTRUCTION <br /> <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", LATEST EDITION. <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E. BLOCKING OR GABLE END BRACING) SHALL BE EITHER <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br /> <br />DESIGN WIND PRESSURE: <br /> <br />(COMPOI\ENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br />WINDOWS AND DOORS <br />123 MPH + 38 PSF / - 40 PSF <br /> <br />GARAGE DOORS (V = 123 MPH) <br />SINGLE 9x7 +37.0 PSF / -40.0 PSF <br />DOUBLE 16x7 +37.0 PSF 1-41.0 PSF <br /> <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br /> <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORlDABUlLDn-:G <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYRHILLS ORDINANCES <br /> <br /> <br />ENGINEERED PLANS <br />ON FILE <br /> <br />REVIEWED <br />HAY 1 0 2005 <br /> <br />~~ <br /> <br />COLONIAL GRANDE 2003 <br /> <br /> <br />GENERAL NOTES: <br /> <br />THE FOLLOWING TECHINCAL CODES <br />SHALL APPLY: <br />2001 FLORIDA BUILDING CODE, <br />WITH 2003 REVISIONS <br />PLUMBING, MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />AND NFPA 70-02 NATIONAL ELECTRICAL CODES <br /> <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WALL MOUNT WATER CLOSET VOLUME <br />3.5 GALLONS <br />3. WATER - FLOW RATE. <br />PUBLIC FACILITIES 0.5 G.P.M. <br />PRIVATE FACILITIES 2.2 G.P.M. <br />SHOWER HEADS 2.5 G.P.M. <br />4. ALL WATER LINE PLUMBING <br />TO BE PVPC <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBC. <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />D HANDRAILS - SECTION +007.5 <br />D GUARDRAILS - SECTION 1015, 1019.9 <br />D STAIRS - SECTION 1007 <br />D CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />D EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />5. ALL OPENINGS SHALL COMPLY WITH <br />2001 FBC WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WiNDOWS, <br />DOORS, SLIDING GLASS DOOR? <br />AND O.H. GARAGE DOOR~ ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFICATION $HEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, A~D ROOFING. <br />, I <br /> <br />6. ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />7. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS. <br />(SECTION 2405,2) <br /> <br />SHT NO <br /> <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />S-1 <br />S-2 <br />S-3 <br />S-4 <br />8-5 <br />S-6 <br />S-7 <br /> <br />S-8 <br />S-9 <br />S-10 <br />S-10A <br />S-11 <br />S-12 <br />S-13 <br />S-14 <br />S-15 <br />S-16 <br />S-17 <br />S-18 <br /> <br />INDEX OF DRAWINGS <br /> <br />TITLE <br /> <br />COVER SHEET <br />FLOOR PLAN <br />FOUNDATION PLAN <br />ELECTRICAL PLAN <br />ELEVATIONS <br />TRUSS LAYOUT <br />MASONRY DETAILS <br />LINTEL PLAN AND DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br />STRUC. NOTES & <br />HANGER INFORMATION <br />DETAILS <br />DOOR DETAILS <br />ROOFING DETAILS <br />ROOFING DETAILS <br />GARAGE DETAILS <br />DETAILS <br />PRODUCT APPROVAL <br />WINDOW DETAILS <br />SGD DETAILS <br />DETAILS <br />DETAILS <br />DETAILS <br /> <br />NOTICE TO BUILDER <br /> <br />IT IS THE INTENT OF THIS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT. <br />IN THE EVENT THAT SOMETHING IS UNCLEAR <br />OR NEEDS CLARIFICATION..STOP..AND CALL <br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT <br />IS THE RESPONSIBILITY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />BEFORE ANY WORK IS DONE. <br /> <br />W <br />LL.~O::: <br />'00:::0 <br />W LL.LL. <br />I-w I- <br /><to~z <br />~-O:,) <br />W x~o:::o <br />() o:::)LL.u <br />L- O:::OZU <br />r- Cl.."""w<t <br />O Cl..""'~1- <br /><to<to <br />Z wO:::l-z <br />O:::LL.w <br />W <tzo:::o <br />fr'l ow<to <br />'-J W~(/)o <br /><:( I-~ZZ <br />L- 0 o<t <br />r- :,)w-w <br />o o~~~ <br />o ~(/)w<tz <br />LL (.?z~EEo <br /><toooi= <br />w 5U;0:::1-C) <br />0:: o~Q~::J <br /><:( LL."""o:::UCl.. <br />w:::;wOCl.. <br />::) O:::Ol-ffi<t <br />a <t -" ~ -" <br />:,) -" . 0::: -" <br />(j) o(/) <t (/) 0 <t~ <br />0:::-"" <br />-"W-"O <br />-">~zo:: <br /><to:><tO <br /> <br />en <br />Q,)Q,)-" <br />(/)10;2 <br />~.u ~ <br />~ ~ ~ <br />I en 0 <br />(/)calS: <br />Q,)c8 <br />- 'OJ) i:i: <br />(0-- - <br />...enb:: <br />OQ,)w <br />e'au <br /> <br />-" <br /><( <br />0::: <br />I- <br />~ <br />o <br />(/) <br />(/) W <br />o U <br />-"('I')i:i:x <br />OJ 0 LL. <t <br />w I'- 0 LL. <br />(.? C\I ('I') ~ <br />z('l') ('1')0 <br /><t-"('I')('I') <br />0::: LL. C\I C\I <br />o . 00 <br />.;2 0000 <br />(/) Cl.. a;:> a;:> <br />Ii) 0 I'- I'- <br />~o... 00 <br />O'l<t~~ <br /> <br />~il' <br />~ c:::::J 0 <br />~<(rn <br /> <br />(/) <br />w <br />o <br />(.? <br />z: <br />o <br />-" <br />:,) <br />OJ <br /> <br /> <br />W (.? 0 <br />I z: 00 <br />1-. (/) :s: N Z <br />(.?zw <tu)~ ~ <br />(/)~Qo O:::NU) (I) <br />. of-O o.-i=l:t: Z <br />ffiz<tu w~lRri 0 <br />w<t~(.? II=l:t:, ~ <br />~ti;!:!::z I-I-..JUl :l <br />(.? 0::: U 0 0::: LL. U. Q. ..J <br />zw~-" OOwz 0 <br />wO(/)S(/)LL.ZQ.Ul (I) <br />WZ(/)OJZOO ~C Z <br />I:,)ZwOWi=ZO:: <br />l-o<!:IU5<i.O:::~:J CJ <br />LL.z....Jf->wOoa:l (i) <br />O<tCl..IW(/)Cl..o::..; LIJ <br />I-W-"I-O:::o-"a:I..J C <br />~(.?~:s:('I')Z~ 'Ul J <br />OJO:,) 0<t:,)<C<C ..... <br />WI->-O I-..JJ: C <br />W:;;U-"C\lOuo::(,) ;:;:: <br />I:>:::)Cl.. W:,)<C- ... <br />f-00:::~~60:::(,)::!E 0 <br />8 ~ t;; 8 :s: U5 t;;DD ii <br /> <br />O'l <br />o <br />('I') <br />C\I <br />o <br />00 <br />~ a;:> <t <br />I- b(/) <br />E ~o::: <br />~ ~~ <br />0('1') - <br />aso~<-'<t <br />~~~~~ <br />C('I'),_Jw"- <br />co -" ~ <t I- co <br />OLL.c;j~<t..-i ~ <br />"I-U"" <br />. co I'- -"-' <br />(/)~ou!:!::..-i <br />Q.~:::)I-O'l W <br />..-i 0 0::: 0::: . I- <br />li)Q.II-WO<t <br />O'l<tCl..(/)UZ 0 <br /> <br /> <br /> <br /> 0 <br /> 0 <br /> 1.0 <br /> w <br /> ~ <br /> - 0 <br /> :J <br /> U1 q- r--. <br /> r- <br /> . r--. <br />z 0 r- <br />I l\1 <br />0 > ID <br />- ..J 0 III <br />U1 r1l I <br />1.0 ID <br />- <br />> W ['l'] 1.0 <br />- r! ['l'] r--. <br />Q 0 I <br />~ I ..J ['l'] <br />U1 l.L. r- <br />II ~ 00 <br />I ~ <br />U1 I <br />~ W II r- <br />~ ~ I <br /> ~ <br /> . ~ <br /> Z <br /> 0 <br /> 0 <br /> 1.0 <br /> 0 <br /> z W <br /> " Z <br /> v;~S:2 0 <br /> WI--V)W:J <br /> ozv)::::!< <br /> O-I> <br /> ~2!:::~v) <br /> <NWo::~ <br /> ",.-j~Oo <br /> ~o::ooO <br /> ~OWWU <br /> <lJ..I-'1-- <br /> O::Oi-l5z: <br /> O::Jo::V)~ <br /> ~;;:~OO:: <br /> ~~<~B <br /> <br /> z <br /> 0 <br /> (/) <br /> > Ii) <br /> C\J (j)wo <br /> 0:::" <br /> 1.O ZUO'l <br /> Of-" <br /> C\J <t('l') <br /> (j) Ii) Cl.. <br /> ...-i _O'lO <br /> >('1')" <br />0) w..-iO <br /> '~ <br />C/) o::~~ <br />(Y) <br />~ -I w <br />-I <br />0 0 <br />- ~ <br />I z w 0 <br />I 0::: <br />N <( () >-LL.z <br /> Zl-O <br /> <tz- <br /> 0:: (V) zw~ <br />L!) S r- -(/)> <br /> 0 OZo <br /> 00 t30<t <br />I Z :,)Uo <br />F'- lLJ -10 oz- <br /> oWO::: <br /> <(N r- o:::t:g <br />~ - Cl..-LL. <br />> I wo:::-" <br /> - O:::~<t <br />~ Z (D wwO::: <br />J- OJII- <br />wO I-I-~ <br />L!) Ol-U <br />C/) 0:: z:::) . <br />~-I >-0Cl.. <br />~ <!:O >- <tIO::: <br />lLJ ~!:::O <br />~() 0... z:S=u <br /> ::so:::w <br /> 0:: 0 w~ <br />>- <!: Cl..zO <br />-I () (/)ZI <br />U 0... -<t(/) <br />0:: ~~:,) <br /> SHEET NO. Cl.. <br />0 0::: <br />0) 1 0 <br /> U <br />J- w <br />(Y) ~ <br /> 0 <br />Z OF I <br />~ 25 (/) <br /> :::) <br />lLJ ('I') <br /> 0 <br />J- 0 <br />> LAST PLOT DATE C\I <br /> @ <br />0 March 10, 2005 <br />Z COVER SHEET <br />-I <br />- <br />