Laserfiche WebLink
<br />GsENERAL NOTE8: <br /> <br />THI~ OOlL.PING l-IA~ aEEN Oe61GNED TO CONFORM TO THI! FLORIDA aUl\..PING CODE 2001. <br /> <br />~,f<KAY' ENGINEl:f<ING INC, A f<EGI&TEF<ED LICENeED, FLOf<IDA Ff<OFEeeIONAI. &Tf<UCTURAI. <br />ENGINEERING COMPANY, HA& APPI.IED " RATIONAl. ANAl. Y&I&" FOR THE &TRUCTURAI. DE&IGN <br />OP THI~ &TRUCTURe <br /> <br />THE 6WLDING ( INCLUDING ALl. cOMPONENT& AND cLADDING& &HAU 6e DE&IGNED FOR THE <br />FOU-OUIING 6UPERiMPOe.eo LOAO& <br /> <br />FLOOR&I <br />I..IVI! 1..0AD& - 40 P.&.F. <br />DEAD LOAD& - 10 P.&.F. <br /> <br />GARAGI! 61..Aa, <br />UVI! L.OAD& - 50 p.e.F. <br />DEAD LOAD& - 10 p.e.F. <br /> <br />ROOF. <br /> <br />UJIND. <br /> <br />LIVE! LOAD& (Tf~uee TOP CORD) . 20 p.e.F. <br />DEAD 1..0.AD& <TRue& TOP CORD) .10 P.&.P. 1& p.e.p. UJHEN TILE ROOP IN&TAL.L.IED <br />I..IYI! L.OAD <TRuea eoTTOM CORD) - 10 F.&.F. <br />Ae&lMED TRU&6 eaF LlJEIGHT ( DEAD LOAD) ., p.e.F. <br /> <br />6UILDING 1& DEe-IGNEO TO CONFORM TO A6CE ,-~&. c~APTER ~, PER FLORIDA 6UILPING <br />cODe 2001 eECTION 160~.1.1 <br /> <br />UJIND DEelGN A66UMFTION&. <br /> <br />" <br /> <br />eUIL.DING EXFO&lRE . 6 <br />OOIL.DING IMPORTANCI! FACTOR. 1.0 (CATEGORY' II) <br />MEAN ROOF HEIGHT 30' OR L.Eee <br />HEIGHT' EXFO&lRE ADJJaTMENTe COE1=FICIENT . 1.0 <br />ENCL.OelED OOII-DING <br />INTERNAL PRE&6URE COE1=l=ICIENT .. I .O.IG <br />eeE LlJINO &FEEO INFORMATION eTATEO ON FLANe <br />T'rPI! , CON&TRUCT10N <br /> <br />eOI1- BEARING. COMFACTIONs <br /> <br />THEel! FI..AN& ILIERI! DRAUJN eAelED UPON AN AU-OUJAaU! eOI\.. aEARING CAPACITY' OF <br />2000 F.e.p.( MINIMUM) THI! CONTRACTOR/PROPERTY' OWNElQ 1& REeFON&leLI! FOR YERIFfING <br />TI~AT THE &011. ON THE elTE 1& FROPERLY' PREpAREO AND COMPACTED &..lCH THAT IT CAN <br />6UPPORT A 2000 p.e.p. FOUNDATION LOADING <br /> <br />ARKAY' ENGIN~RING INC. A REGI&Ta<ED LICEN&ED FLORIDA PROFEe&IONAI.. &TRUCTURAI.. <br />ENUINEERING COMPANY', DEelGNED THEeE FOUNDAT10N& LlJITl-lOUT VlelTING THE CON&TRUCTION <br />&lrE NOR PERFORMING ANY eolL TE&TING <br /> <br />AAKA Y ENGINEERING INC &~AU NOT BE RE&PON&IBLE FOR THE &ITE 50IL AaIL.ITY TO &lPPORT <br />THE 6UIL.DING LOAD& <br /> <br />FOUNDATION. aLAe - ON- GRADE NOTEa , <br /> <br />aUIL.DING 61TI! ~!..1- eE ~CRAPEO TO REMOVI! AL.1.. ORGANIC MATERIAL&.. <br />ANY ADDitiONAl. FILl- PLACED ON THE BUILDING PAD AREA, ~~AU aE COMPACT EO <br />&!JC11 THAT IT CAN ADEQUATEl.Y &lPPORT A 2000 P.&.F. FOUNDATION LOADING. &LA6 <br />el4AL.1- al! PI..ACI! ovm A 6 MIL. VAPOR eARRIER ON CI..I!AN ADEQUATEL.Y' COMPACTIED <br />AND TERMITE POI&ONED eoll.. <br /> <br />CONCRETE UTILIZer> IN THE FOUNDATION AND e.LAa& e.HALL ~AvE A MINIMUM 28 DAY <br />cOMPREe&IVe eTREN:GTI1 Of! 2~0 P.&.F. <br /> <br />REINFORCING eTI$. ~AU ae GRADE 40 MINIMUM AND IDENtiFIED IN ACCORDANCE <br />UJITl-l AeTM A -~I". LAP 6PLICE&, LlJHERE REQUIREr> &HAL.1. Be A MINIMUM OF 2~" FOR <br />~ REaAR . roO I'OR .~ REaAR . ~~" FOR ., REaAR <br /> <br />pLANe ARE ENGINEERED FOR A MAXIMUM &TEMWAU HEIGHT OF.4 COURe.E& ( AFtER <br />FINAl. &ITE GRADING) THE CONTRACTOR OR 6UILDING OLlJNER ew.U DETERMINE THE <br />EXACT &TEMUJAl..l.. HEIGI1T eA&E UPON &ITE CONDltION& PRIOR TO POURING TI1I! FOUNDATION <br />AND CONTACT ARKAY' ENGINEERING w..lEN MOf<E T~AN .4 COUR&E ARE REQUIREO <br /> <br />A FOUNDATION 6URVEY ~HAU el! PERFORMED AND A COpy OP THE 6URVEY ~HALI.. al! ON elTI! <br />FeR THE 6UILDING IN&PECTOR! U&E . OR ALL PROPERTY MARKER& &HAL.L BE EXPOeEO AND A <br />eTRING &TRECTEO FROM MARKER TO MARKER TO YERFIY REQUIREO eET 6ACK& <br /> <br />MAeONRY WALLe, <br /> <br />CONCRETE MA&oNRY UNIT eMAL.L 6E HOLL.OW UNIT MA&oNRY IN ACCORDANce LlJITH A&TM C-~O <br />AND &HALL HAYE MINIMUM P'M OF 15<00 P.&.I. <br /> <br />MeRT AR &HALI- CONFORM TO A&TMC -210 AND ~~AU Be EITHER TYPE 1'1 OR & <br /> <br />Rt:INFORCING &ren ew.L.1.. eE ~RADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />LlJITH A&TMA-6Il? LAP 6PI.ICE& LlJHERE REQUIREO eHAU ae A MINIMUM OF 2~" FOR ., REaAR <br />30" FOR 'ao REa.6.R AND ~!;" FOR ., REaAR. <br /> <br />~ROUT FOR THE POJRED Ca.L.& AND LINTa& &HAL.L HAYE A MAXIMUM COUReE AGGREGATE &IZE <br />OF 3/a" PLACED ,~T a TO II INCH &LUMp AND HAYE A MINIMUM 2a DAY COMPREeelYE &TRENGTH OF <br />2000 P,~.I. ( WHEN Te&TED PER A&TM C-IOI<:l ) <br /> <br />PROVIDE CLEAN OUT OPENING& ( 12 ~. IN. ) IN CEU& CONTAINING &pLICED REINFOf<CEMENT. LlJHEN <br />THE ~ROUT POUR EXCEED& , FEET IN HEIaHT <br /> <br />ROOFING . FL.Ae~INGe, <br /> <br />ROOFING &Y&TEM AND FLA&~ING Ae eTATED IN PLAN& MU&T CONFOf<M TO CHAPTER 11; OF THE FLORIDA <br />eUll..DING CODe 2001. FI.A&HING e,PECIFIC eeCTION 150'.).~ CONTRACTOR OR OUJNER MU&T PROYIDI! LlJITI1 <br />PLAN& e,PECIFIC PRODUCT INFORMATION DeTAIL.ING IN&TAU-ATIoN 01= PRODUCT TO MEET UJIND DEe.IGtN& <br />OF THI& &er OF C'RAWING&. <br /> <br />TINSER MATERIALe: <br />ALL TIMBER& MATERIAL& ~HALL aE A& FOLLOLlJ&. <br /> <br />LVL eEAM& el-lALL al! n.~J!) MCAU-I&TER I-YL MATERIAL& MANUFACTURED ay TRU&& JOI&T <br />MACMIU-AN ( OR EQUAl.) <br />L.UMaER UTILiZer:> IN eOTTOM PLATE, TOP PLATE& ,PO&T, eTUD& PAcK& AND aEAM& <br />el4AL.1- al! "2 'ra.LOW PINI! (OR eEriER) <br /> <br />EXTERIOR AND INTERIOR LOAD BEARING eTUD& ~AU 6E "2 &PRUCE ( OR aETTER) <br />Af-L OTHa< &TUO& &HAU- al! "&TUO GRADe" &PRUCe &PACI! 16" OC. AU- &PI..ICE& AT <br />TOP FI..ATE MU&'r e.e MINIMUM 4'0" AND NAllJ:O 4" OC LlJITI-l12D COMMON NAILe <br /> <br />P&1- PoeT ~HAW_ al! n.&EJ PARAI-J.AM P~1- MATERIAL.& MANUFACTURE& aY' TRUe&JOI&T <br />MACMIU-AN (OR EQUAl.). &EE PoeT 6UpPORT TAaLE FOR LOAD YALUE&. <br /> <br />EXTERIOR WAL.LE) eHAU- al! CON&TRUCTIED WITI1 112" PI. Y'WOOD OR 1"6" 0,&.6. ( 2-M..UJ RATING) NAIl-EO <br />UJITI1 ~D NAIL.& &PACI! AT )" OC AL.ONG AL.l- I1ORIZONTAI- JOINT& AND EDGE&, ~" OC ALONG AL.1.. YERTICAL <br />JOINT& AND EOa,E& AND 12" OC ALONGI AU INTERMEOIATE eTUD& <br /> <br />Ar OPENING& ~'o" UJIDe OR J.ARGER &TRAP HEADER eEAM TO THe HEADER &TUD& UJITI1 (2) U~P OR 61MP&ON <br />L&TA24 eTRAP TIE& AT EACH END OF HEADER aEAM. ANCHOR eoTTOM OF HEADER eTUD& TO FOUNOATION <br />LlJITH U&P OR el1'1F&ON ~TT1~ TEN&ION TIlL <br /> <br />INTERIOR eTUD UJAu..& TO BE OF 2 ~ 4 t2 &PRUCI! OR 6enER WITH &\NGLE 2 ~ 4p.T. <br />PiN!! aOTTOM FI.ATE AND &INGI..!! 2 ~ .4 "2 &FRUCe TOP PLATE LlJITI-l &TUD& &pACEO <br />MAXIMUM 24" OC. UJALL& TO HAYE! In" G'rP6UM eOARO I!ACH ~IDI!, WITH UJAU-& AT <br />GARAGI! TO HAYI! MINIMUM R.II IN&ULATION <br /> <br />ANCI10R UJOOD '*4i:AR UJAU-& 65GMENTe TO FOUNOATION UJITI1 ~IMP&ON 1-TT206 TeN~ION TII! AT I!ACl-l <br />END 01= WAL.l- &EGMENT& AND AT ANY' WALL &EGMENT INTER&ECT10N ( ISUII.DING CORNER&) <br /> <br />ALL pLUM6ING. E:L.ECTRICAI- AND MECHANICAl- ROUGt4 IN& MU&T eE COMPLETE, IN&PECTED AND APPROVEO <br />PRIOR TO REQUiS6TING THE FRAMING IN&PECTION. <br /> <br />IF DE&IRED, EGlUIVAUENT CONNECTOR& MADE BY ANOT~ER 6UPPLIER MAY' BE U&ED IN PLACE OF THE <br />U~P OR 61MP&oN CONNECTORe &HOWN <br /> <br />THI: CLll::Nr UNOEf<arANO~ TI-IAT TI-II: DE&lcaNSR CA~~IEa NO L.IAelL.JrY IN&U~NCI: AND Tl-IERa=<::>F<1: <br />h~REE& TO HOLD f.lARMLEe&, IDEMNIFY. AND DEFEND DE~IGNER FROM Al..J. CLAIM&, LOe&E& AND <br />I!X"PENeE& (lNCL.UDINGI fO:P.AeO~lS: ArTORNIff FEE&) ARlelNGI OUT OP OR REeuL TINGI FROM THS <br />PROJECT. TI-Ie DEelUNER UJILJ. IN GOOD FAITI-l ATTEMPT TO p~OYIDe ERROR FREe CONetRUCTION <br />D~WING&. eUT IN THe EVeNT ERRORe OCCUR THE! DE&IGNER WIL.!. NOT ee L.IAelJ! FOR coaT OF <br />REPAIF<& OR DeLAY TO 'rHIi CONeTRUCTION <br /> <br />8011- TERMITE TREATMENTs <br /> <br />INITIAL &OIL. POI&ONING TREATMENT ~l-lAll. ae DONI! AFTER AL.1- EXCAYATION <br />6ACKFILLJNet . COMPACTINc. ARI! COMPlETl! (PER F6C 13Ih.I.U <br /> <br />ANY &oIl- DI&TURew AFTER TI1E INITIAL TREATMENT el-lAU. aE RI! TREATer:> <br />( INCI-UDING ANY eoXIED OR FORMED AREA&) (PER F6C 1&16L2.) <br /> <br />aoxw AREA& IN THE CONCRETE! &LAa FOR IN&TAUATION OP TRAF& &1iA!-1. BE MADE <br />UJITH PERMAMENT MeTA/.. OR PJ.A&T1C FORM&. PERMAMENT FORM& I1lJ&T ee OP AN AOEQUATe <br />&llE . DEPT~ TO ELIMINATE ANY DI&TURBANCE Oil THE &011. AFTER THE INITIAl. TREATMENT <br />(PER Fee 181~.I.3) <br /> <br />A MINIMUM ~ MILL vAPOR 6A1'<RIER MU&T eE IN&TAll.EO TO PROTECT AGAIN&T RAINFAU. <br />DILUTION IF RAINFAL.1. OCCUR& aErORE VAFOR aARRIER PLACEMENT, RE TREATMENT ~HAU. <br />51! R!:QUIRIED (PeR Fee 1&16.1.4) <br /> <br />ALL. 6UfLDING& Af<E REQUIf<ED TO HAVE A PF<E CON6TRUCTION TERMITE TREATMENT <br />(PER FaCI&I~.'.') <br /> <br />AFTER ALL UJORK 1& COMPLliTe ANY LOO&E WOOD AND FILL MU6T 6E REMOVED FROM <br />BEl-OW AND WtTI-I IN 12" OF THE 6U1L.DING. THI& eMAU INCLUDE AU GRADE &T AKE& TUe <br />TRAP 60~E&, FORM&, eHORlNG AND ANY OTH~ CELLUI-O&E CONTAINING MA1"ERlAl-& <br />(PER F6C 230'.1.') <br /> <br />NO WOOD YEGETATION, &TUMF&, CARDeOARD, TRAel-l, ETC, eHAU.. BE 6URIW UJITI-IIN I~' 0" <br />01= ANY OOI!..DING OR PROPO&ED eUIt..DING <P~ Fee 230)1.4) <br /> <br />ANY CONCReTE OVER POUR MORTAR OR &TUCCO MATERIAI-& AL.ONG THe FOUNDATION PERIMeTER <br />MU&T ee REMOVED PRIOR TO EXTERIOR &OIL TREATMENT (PER Fee laI6.1.5) <br /> <br />E:XTERIOR &011- TREATMENT MU&T el! APPLIEO UNDER AU EXTERIOR CONCReTl! OR GRADe <br />LlJITHIN 12" OP TI-IE &TRUCTURE &IDE LlJAU& (PER Fee 1&16.1.6) <br /> <br />AN EXTERIOR va<TICAI.. CHS1ICAL eARRIER &l-lAL.1- ee IN&TAUIED AFTER CON&TRUCTION 1& <br />COMPLETE ( INCLUDING LAND6CApING AND IRRIGATION) ANY 6011- DI&TURaW AFtER TI-lE <br />YeRTICAl. eARRIER 1& APFI..ler:>, &HAU el! RETREATED <FER F6C \&\6.\.6) <br /> <br />IRRIGATION I &PRINKl-ER &'r&TEM& INCLUDING ALl. RI&ER& AND &f>RAY HEAD& &I-lAU- NOT eE <br />IN&T AUeo WITH 121 OF THe aUILDING 610EUlALL& (PER Fee 1503.4.4) <br /> <br />CONDENeATI! AND ROOF DOWN &POUT& OI&CHARGe AT LEA&T 12" AWAY FROM THE eul\..PING <br />elDE WAU& (PER Fee 1503.4.4) <br /> <br />THE DI&TANCE FROM THE EXTERIOR LlJAU COYERING (EXCEPTION&. PAINT AND DECORATIVE <br />CEMENTITloue FIN1&t4 LEee THAN 1;181 T~ICI<. ADHEREO OIRECTLY' ONTO Tl-lE FOUNOATION WAW <br />AND FINAl. eARTH GRADE &I-lAI-1- NOT aE LEe& THAN ." TO AUOW FOR IN&f>ECTION FOR FUTURE <br />TERMITE INFE&TATION& (PER Fee 140'.1.6) <br /> <br />A 1 CERTIFICATE OF COMPLIANCE" eHAU 6e le&lEO TO THE 6UILPING DEPARTMENT 6Y' A L.ICENeED <br />PE&T CONTROl- COMPANY' aErORE! A " CERTIFICATE OF OCCUPANCY' UJIll. el! 16&uED. THI! CERTIFICATI! <br />&~ALL &TATE, (PER Fee 181~,1.') <br /> <br />" THI! OOI\..PING HA& RECElYED A COMPleTe TREATMENT FOR THI! PREVENTION OP 6UeTERRANEAN <br />TERMITE&. THe TREATMENT 1& INACCQROANCE LlJITl-l Tl-lE RULE& AND LAW& OP Tl-le FLORIPA DEPARTMENT <br />OF AGRICULTURE AND CON6UMER& &ERVICEe <br /> <br />A PERMAMENT &IGN THAT IDENTIFIE& THe TERMITE TREATMENT PROYIDER AND NEED FOR RI! IN~f>ECTION <br />AND TREATMENT CONTRACT f<ENEUJAI. eHALL. ee Ff<OVIDED. THE 61GN eMALL ee p06TEr> NEAR Tl-lE WATER <br />HEATER OR ELECTRICAL PANEl. <PER Fee 104,2..) <br /> <br />TRueeees <br /> <br />IP THE CONTRACTOR, TRU&& MANUFACTURE OR ANY OTHER DE&IGN FROFE&&IONAI.. REVI&E THE <br />TRU&& &Y6TEM LAYOUT FROH THO&E &HOWN ON THEeE PLAN& ARKAY ENGINEERINet, INC 1& <br />REQUIREO TO REVIEW AU FINAL CON6TRUCTION DOCUMENTe FOR COMPLIANCE LlJITI-l THe <br />DEelGN INTENT FRIOR TO COMMENCEMENT OP THE PROJECT <br /> <br />CAULKED WINDOW PeR YOUR <br />WINDOW MANUFACTURE6 6PECIFIC <br />RECOMMENDA TION& TO MEeT WIND <br />LOAD AND COMPRE&&ION RA TING& <br />FOR YOUR J06 LOCATION <br /> <br />EXTERIOR WINDOWe . DOOR8: <br /> <br /> <br />AtTACH MINIMUM 3/411 P.T. aUCK <br />&TRIP THAT 1& THE! MINIMUM WIDTH <br />OF DOOR FRAMe U61NG .091XI 3/all <br />T- NAIL6 MAXIMUM lOll OC. <br /> <br />CAULK POOR FRAMe PER YOUR <br />MANUFACTURE6 RECOMMENPA TION6 <br /> <br />DO <br />DO <br /> <br />6ECURING PREJ-IUNG TO aUCK 6TRIP6 <br />PER YOUR MANUFACTURE6 IN6TRUCTION6 <br />TO MeET WIND LOAD& AND COMPRE&&ION& <br />RATING& !=OR YOUR JOB LOCATION. ALL <br />ANCI-IOR &CREW& MU&T peNETRATE BLOCK <br />WALL A MINIMUM 01= I 1/411 AND T~eRE &~ALL <br />6E A MAXIMUM 1/4" &PACl: BETWEEN 6UCK <br />AND DOOR JAM6 <br /> <br />6L.OCK DOOR A TT AC~MENT DETAIL. <br /> <br />&ECURING WINPOW TO 6UCK 6TRIP& PER <br />YOUR MANUFACTURE& IN&TRUCTION TO MEET <br />WIND LOAD AND COMPRE&&ION RATING& FOR <br />YOUR JOB LOCATION. ALL ANC~OR eCREUJ& <br />MueT PENETRATE BLOCK WALL A MINIMUM 01= <br />I 1/411 AND T~ERE e~ALL. BE A MAXIMUM 1/411 <br />&FACE 6ETWEEN euCK AND WINDOW FRAME <br /> <br /> <br />GARAGE DOOR TO BE REINFORCED <br />To MEeT WIND LoAD AND COMPREeelON <br />RATINGe FOR YOUR J06 LOCATION. <br /> <br />Ii) <br /> <br /> <br />ATTACH MINIMUM 3/4" P,T. 6UCK 6TRIP <br />T~A T Ie THE MINIMUM WIDTH OF YOUR <br />WINDOW FRAME UelNG ,o~, X I 3/&" <br />T- NAIL6 MAXIMUM 10" OC <br /> <br />I@) <br /> <br />6LOCK WINDOW ATTACf.4MENT DETAIL <br /> <br />ALL EXTERIOR WINDOW& . GLAe& DOOR& OR ENTRANCE DOOR eHAU BE TE&TED IN ACCORDANce WITH <br />AN&I/AMMAlNUAlJOA lOVle2 &TANDARD AND aeAR AN AMMA OR LlJOMA LAaEL IDENTIFYING THE MANUFACTURE <br />PERFORMANce CHARACTERI&T1C& AND APPROYEO PROOUCT TE&rING ENTITY <br /> <br />ALl. MUL.l.loN& AND ADJACENT DooR/UlINDOW A&&EM61-IE& &IiA!-L 6E TE&T OR ENGINEEREO TO TRAN6FER <br />I., TIME& 11-I1! DE~IGN LOAD& TO THI! ROUt::.I-l OPENING &U5&TRATI! <br /> <br />IN&TAI..I. AU. LlJINDOLlJ& AND DOOR Ae&EM6LIE& FER THE MANUFACTURE ANCHORING RECOMMENDATION& <br />TO ACHIEVS THS DE&IGN PRE&&lRE& 6PECIFIED <br /> <br />eLECT~ICAI-, PI-UM6ING, . MECHANICAI-s <br /> <br />IN ACCORDANCE UJITI1 CHAPTER 411.00' (2) (I) OIl THE FLORIDA ADMINI6TRATIVE CODE. ELECTRICAL <br />PLUMBING AND MECHANICAL &Y&TEM& ~AU el! DE&IGNED ay THE RE6PECTIVE CONTRACTOR TO <br />M.EST AU APPL.ICA6L.E CODEe. THE ELecTRICAL., pLUMBING AND MEC~ANICAI. &'r&TEM& DRAWN HERON <br />ARE 6A&e UPON A DE&IGN PROYIDEO 6Y THE OWNER TO ADDREee HI&/HER REQUIREMENTe. <br /> <br />ALL ELECTRICAl. OUTLET& IN BATHROOM&. KITCHEN, (UJITHIN ao' FEET OR &INK&>, GARAGE AND AT <br />EXTERIOR I..OCATION& ~HAU 6E LlJIRED INTO A GROUND FAULT INTERRUPTER "GF'" CIRCUIT <br /> <br />ALl- a.eCTRICA/.. OUTLl!T& IN eEOROOM& . FIXTURE& el-lAL.1. el! UJIRIED INTO AN ARC-FAUI- T INTERRUPTER <br />"AFI" CIRCUIT <br /> <br />~MOKI! Dl!TecTOR& &HA!./.. el! PLACE IN EACl-l eEOROOM AND <br />IN l-lAL.1- UJAY' AREA& ADJACENT TO aEDROOM AND OTHER I-IVING <br />AREA& <br /> <br />8AFETY GLAZING: <br /> <br />THE fOLLOWING ~~AU. aE CON&IDEREO &PECIF\C l-lAZARDOU& LOCATION FOR THE F'URPOeE OF <br />GI..AZING <br /> <br />(1) GLAZING IN &LlJING DooR&. FixED AND &I-IDING PANEl. OF eLIDING DOOR& <br />M6!:MaI..IE& <br />(2) Gl..AtlNG IN DOOR& AND ENCI..O&uRE:& FOR HOT TUe&, WHIRl-POOL&, eAUNAe, &TEAM <br />ROOMe, eATHTUa& AND eHOWER&. ~I..AZING IN ANY PORTION OF A eulLDINet WAU <br />ENCL061NG THEeE COMPARTMENT& LlJHERE 114E aoTTOM EDGE OF THE! GLAZING 1& LE&& <br />THAN 60" AeOVI! THE DRAIN INLet <br />(,) GtJ.AtING IN INDIVII?UAL FIXED OR OPERA61..1! PANEl. AOJACENT A DOOR UJl..la<e <br />THE NEARE6T VERTICAl. EDGE 1& LlJITHIN A 24. RAOIU& OF THE DOOR IN A ClO&EO <br />FO&ITION AND UJI-lO&1! eoTTOM ED~I! 1& I..E&& THAN &0" AeOVE THE FINI611 FLOOR OR <br />WAL.KING &URFACI! <br />(4) GtI..AZINGt IN AN INDIVll?UAl.. Fix EO OR OPERAel..E PANEl. OTI1ER TI-lAN THO&E LOCATION& <br />DE&cRI6ED IN ITEM& (2) AND (3) AaovE . THAT MEET& AU OIl TI1E FOLI..OLlJING <br />(A) EXPO&IED AREA OF AN INDIYII?UAI.. PANE GtREATER THAN 9 ea. FT. <br />(e) eoTTOM EDGE L.Ee& Tl-lAN IG" AeovE THE FLOOR <br />(C) TOP EDGE GREATER TI-lAN 361 AaovE THE FLOOR <br />(0) ONI! OR MORI! WAI-KING 6URFACE& ll.JITI1IN 3&" I1ORI,tONT ALLY <br />OF THI! FI..ANE! 01= THE ~LAZING <br /> <br />D~AF=TeTOPPING, <br /> <br />IN elNGl-e FAMI!.. Y' owauNG&, DRAFT&TOPPING& &HAJ..J.. as FROVfOEO ( PARAU-a. TO THS MAIN <br />FRAMINc. MEM6ER&> IN FLOOR I CEIWNet A&&EMe1.IE& &lPARATINa. U&1!A8LB &PACE&. O~T'TOPPINa. <br />6HAlL. BE CON&TRUCTEO &lC1-l TI-lAT THE FLOOR 1 CelL.ING A66EMSLI!'( 1& SROK!N UP INTO TWO OR MOFtE <br />APPRO~IMATED AREA& WtTI1 NO AREA ~REATER THAN ~ ea.FT. <br /> <br />ATTIC ACCeee: <br /> <br />ATTIC &PACE& &HAI..I- BE PROYIDED UJITH AN INTERIOR ACCEe& OPENING NOT LE&& THAN <br />22"X36". ACCEee OPENING eMAU BE ACCEeeleLE AND pf<OVIDE WITI-I A LID OR DEVICE <br />THAT 1& EA~II.Y REMOVW OR OPENED. UJHEN MECHANICAl. EQUIPMENT 1& IN&TAUec IN <br />THe ATTIC, IT &HAU Be IN&TAL.LEO IN ACCORDANce LlJITI-l MECHANICAl. CODE. <br />ACCE6e 1& NOT REQUIf<ED I1IHeN THE CL.EAR 14ElGI-lT OF THE ATTIC 6FACE, MEA&..lf<ED <br />AT THE ROOP FEAK 1& I..E&& THAN 24". <br /> <br />Ii) <br /> <br />I@) <br /> <br />Ii) <br /> <br /> <br />I@) <br /> <br />CEILING RAFTER <br /> <br />ALL TRACK AND J-IARDUJARe eECURED <br />PER MANUFACTURe ePECIFICATION6 TO <br />MEeT WINP LOAD ANP COMPRE&&ION <br />RATING& FOR YOUR J06 LOCATION <br /> <br />MINIMUM 2 X 6 P.T. 61pe AND TOP PLATe <br />ATTAC~ED TO ISLOCK WALL U61NG 11211 X a" <br />ANCOOR BOlT& OR 5/&" X 111 EXfOAN&rON <br />60L T6 4 EAC~ &IPE AND TOP 24" OC <br /> <br />GARAGE DOOR A 11 AC~MENT DETAIL. <br /> <br /> <br />V2" &EiTeACI<. TO AL.LOW <br />FOR "Va" LAtW&rucco <br />V211 (\!;/32.) PL. Y'IJ.IOOD &HEA THING (TYP) <br />OR VI.1 oea &HEATHING FA&TENED W/&D <br />NAIL& . 31 OC MAX. <br />ATTACl-l WINDOW. DOOR FRAME TO AF<C14 FRAMING <br />WlrH '10 &cREW& epACEO PER MANUPACTURE <br /> <br />3/4" BUCI<.6tRIF& ATTAC14\:D TO t=RAMING Muet !EXtEND <br />BEYOND WINDOW FRAME TO PROVIDe FULL &UPPORT <br /> <br />2 X a F.T. ( f<IPPED A& f<EQ'D) HEADER MAY' 6E <br />ATTACHED TO Bl.OCK WI '/&" EXPAN&ION OR EF'O~Y-&ET <br />ANCl-lOR& . HAX &N FROM END AT '21 OC MAXIMUM <br />eETWEEN, EaUAL.LY' &PAC\:D AND &TAOOER\:D IN L.IEU <br />OF liT APCON" ANCHOR& <br /> <br />.. <br /> <br />I <br />I III <br />I <br />~------------------- <br /> <br /> <br />NOT!:, IF &PAC!: . CENTER OF ARCI-l 1& .4 1/2" OR u:&& <br />DEl-ETE 2 X &, PROVIDE &oLID E'LOCKING TO MA&oNRY <br />eEAM Al90YS <br /> <br />D61.. 2 x & . CENTER 01= ARCl-l ( RIPPED 06.& REQ'D) <br />AitACl-l EACI-l LlJ/&IMP50N '~4 CI.IPe, TWO. I!ACI4 END <br /> <br />2 X & P.T. ( RIPPe:> A& Rl:a'D) AT1ACHI:D TO el.OCK <br />WI2 - 311e," "TAPCON&" . EACl-l END AND AT e,. O.C. <br />MAxli'1.lH eElrwe~ EGlUAlJ.Y &PACS) ANO &TAac.iif<Et> <br />( ""INI , II'" JiiiNJlnUT1"N INfO Itt-OlSl< J <br /> <br />MA&oNRY 6LOCK <br /> <br />2 X .4 aLOCKING AL.ONG EDGE PF ARCH OPENING <br />epACW MINIMUM &1 (MAXIMUM 10" O.c,) <br /> <br />V2" X 4" 6ICI<.&tRIP Al.ONG ARCI1 OPENING <br /> <br />A~Cf.4 WINDOW FILL - IN - DeTAIL <br /> <br />AF<I<.AY' ENGINeERING INC. <br />&TRUCTURAI. ENGINEER& <br /> <br />RICHARD L. KIDDl:'r" P.E. <br />F!.ORIDA LICEN~E! NUMeER '~ca6 <br />I HERBY CERTIFf THAT TI1E&1I P~N& AND ~PECIF1CATION& <br />WA& P~EPAREO BY ME OR UNDER MY DIf<ECT &UPERVI&ION <br />ARE IN COMPLtANCE I1Iltl-l THE I=L.ORIDA BUiLDING CODE 2001 <br />FOR 110 MP~ (, &ECOND GUeT) WIND Z:ONE-~ MP~ M&TE&T <br />&Ps:D <br /> <br /> <br />o <br />r-. C/) <br />o z <br />~ ~ <br />o f"- - <br />zC/)U)<offj <br />-..~~~ Q <br />~Q.;MlI)-' <br />~>MM~ <br />Ri:~~ffi <br />acnE( :Ii <br />~~~J::~ <br />~:c ..00 <br />~cn~~~ <br />~:)O~<1 <br />~~~. ~t= <br />Zooc(lI)Z <br />~~o~~ <br />o - <br />fE ~ <br />o <br /> <br /> <br />r <br /> <br /> <br />~~H <br />-~~I <br />U._\)~ <br />~ jiL <br />- ~ ~ ~ ~ <br />~ ~ ~!H <br />1_ N 'oil. <br />_ W ~ ~ <br />Ji ~ 5;~ <br />~ ~ $~~ j <br />~ ~ 3lm ~ ~ <br />'<t :f J\ .Q it <br />~~u.-J <br />"}01 <br />tJ~ <br /> <br />I <br />I <br />6 <br /> <br />~ <br />~ <br /> <br />~ <br /><{ <br />Q <br /> <br />~ <br />a <br />~ <br />~ <br />~ <br /> <br />3 <br />II <br />~ <br />I <br /> <br />~ <br />~ <br />(l <br /> <br />. <br /> <br />~ <br />~ <br /> <br />('C\ <br />~ <br />~ <br />~ <br /> <br />~ <br />Q <br /> <br />- <br />- <br /> <br />~rr <br /> <br />""" ~' <br /> <br />~j ~ <br />~;t~ifl <br />~ ~~~ <br />~ ~~~ <br />~..~~ <br />~ ID ~ <br />tj ~~M <br />~ It: ~ <br />~ ~ ~~ <br />lk~ <br /> <br />z <br />~ <br />Q.. <br />~ <br />:t <br />~ <br />f- <br /> <br />LIVING 13'~ <br />GARAGE 424 <br />liNT_V 'IIJ <br /> <br />TOTAL. <br /> <br />1828 <br /> <br />PG <br />6 OF to <br /> <br />A~KAY · 71;107 <br />