<br />ENGINEER/S <br /> <br />NOTES: <br /> <br />1. <br />2, <br />3, <br />4. <br />5, <br /> <br />wIND DESIGN SPEED 110 MPH (3 see gust) <br />THE wIND IMPORT ANCE F ACTOR IS 1.0 FOR RESIDENTIAL HOME <br />THE wIND EXPOSURE FOR BUILDING IS CATEGORY I'B'I <br />THE APPLICABLE INTERNAL PRESSURE COEFFICIENT = +.18/-.18 <br />THE DESIGN wIND PRESSURE COMPONENTS ~ CLADDING (ROOF) <br />ZONE 1 ZONE 2 <br />@ 10 SQFT +12,5/-19,9 @ <br />@ 20 SQFT +11.4 /-19,4 @ <br />@ 50 SQFT +10,0 /-18.6 @ <br />@ 100 SQFT +10,0 /-18.1 @ <br /> <br />ACCORDING TO THE 2001 EDITION FLORIDA <br />GAS) ENERGY EFFICIENCY) ACCESSIBILITY) <br />/ <br /> <br />BUILDING) <br />AND 2002 NATIONAL <br /> <br />PRE-CAST AND PRE-STRESSED CONCRETE COMPONENTS SHALL BE USED AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS, PRE-CAST LINTELS HAVE <br />BEEN REVIEVlED AND PLACED BASED ON DESIGN ALLOVlABLE LOAD INFORMA TION PROVIDED BY SPECIFIED PROVIDER, ENGINEER <br />OF RECORD MUST PROVIDE IN VlRITING ANY CHANGE IN LINTEL MANUF ACTURER, ALL OTHER STRUCTURAL PRE -CAST COMPONENT <br />MANUFACTURERS MUST SUBMIT DESIGN LOAD INFORMATION TO ENGINEER OF RECORD FOR APPROVAL, ENGINEER OF RECORD RESERVES THE RIGHT <br />TO MAKE ANY CHANGES AFTER SUCH INFORMATION HAS BEEN PROVIDED FOR REVIEVI, CONTRACTOR; AS PROJECT COORDINATOR, SHALL BE <br />RESPONSIBLE FOR INSURING INFORMATION REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER OF RECORD IN A TIMEL Y MANNER wHEN AVAILABLE, <br />ALL ROOF CLADDING PRODUCTS ARE THE RESPONSIBILITY OF THE MANUFACTURER, THE ROOF CLADDING MANUFACTURER IS RESPONSIBLE FOR <br />THE VALIDITY OF COMPONENTS PROVIDED, ATTACHMENT INFORMATION GIVEN BY THE MANUFACTURER IS PROVIDED HEREIN, CONTRACTOR, AS <br />PROJECT CORDINATOR) SHALL BE RESPONSIBLE FOR INSURING THAT THE APPROPRIATE ROOFING MATERIAL IS USED AND THAT IT HAS BEEN <br />INSTALLED PER MANUFACTURER1S SPECIFICATIONS SUCH THAT IT VlILL VlITHSTAND THE COMPONENTS AND CLADDING PRESSURES REQUIRED BY <br />THE SEALED PLANS, <br />ALL PRE-ENGINEERED VlOOD PRODUCTS SHALL BE VERIFIED BY TRUSS MANUFACTURER, TRUSS MANUFACTURER SHALL HAVE THE AUTHORITY <br />TO MAKE SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO AVAILABLITY DR ECONOMICS, CHANGES SPECIFIED BY THE TRUSS <br />MANUF ACTURER SHALL CONTROL, CHANGES MADE AFTER TRUSS ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD, MUST BE <br />APPROVED BY THE ENGINEER OF RECORD, <br />THE ENGINEER HAS NOT REVIEVlED THE PRE-ENGINEERED TRUSS MANUFACTURER'S LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS <br />AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER, <br /> <br />ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED USING THE MOST RECENT TPI CRITERIA, TRUSSES TO BE HANDLED AND INSTALLED USING MOST RECENT <br />HIB RECOMMENDATIONS, TEMPORARY AND PERMANENT BRACING SHALL BE PER MOST RECENT HIB RECOMMENDATIONS UNLESS NOTED OTHERVlISE, DR <br />MORE STINGENT CODE REQUIREMENTS APPL y, TRUSS ENGINEER IS RESPONSIBLE FOR INDICATING ALL TRUSS CONNECTIONS, ALL COMPONENTS TO BE <br />DESIGNED FOR BOTH GRAVITY AND UPLIFT LOAD CASES) INCLUDING BEAM COMPONENTS, <br /> <br />ALL ~ORK TO BE COMPLETED <br />PLUMBING) MECHANICAL) FUEL <br />ELECTRICAL CODE <br /> <br />10 SQFT <br />20 SQFT <br />50 SQFT <br />100 SQF T <br /> <br />+12,5/ -42.1 <br />+11.4/-38,2 <br />+10,0/-33 <br />+10.0/-29.1 <br /> <br />THE ATTACHMENT OF ASPHAL T SHINGLES ON THIS PRODUCT MUST BE IN COMPLIANCE VlITH ASTM D3161 (MODIFIED TO 110MPH) DR M-DC PA 107-95, <br /> <br />THE DESIGN wIND PRESSURE <br />ZONE 4 <br />@ 10 SQFT +21.8 /-23,6 <br />@ 20 SQFT +20,8 /-22,6 <br />@ 50 SQFT +19,5 /-21.3 <br />@ 100 SQFT+18.5/-20.4 <br /> <br />COMPONENTS ~ CLADDING (wALLS) <br />ZONE 5 <br />@ 10 SQFT +21.8 /-29.1 <br />@ 20 SQFT +20,8/-27,2 <br />@ 50 SQFT +19,5/-24,6 <br />@ 100 SQFT+18,5/-22,6 <br /> <br />TERMITE PROTECTION: <br /> <br />A VlEATHER RESISTANT JOB SITE POSTING BOARD SHALL BE PROVIDED TO RECIEVE DUPLICATE TREATMENT CERTIFICATES AS EACH REQUIRED <br />PROTECTION TREATMENT IS COMPLETED, PROVIDING A COpy FOR THE PERSON THE PERMIT IS ISSUED TO AND ANOTHER COpy FOR THE BUILDING <br />PERMIT FILES, IF THE SOIL CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR <br />TO FINAL BUILDING APPROVAL, (FBC-104,2,6) <br /> <br />}t THE TREATMENT CERTIFICATION SHALL PROVIDE THE PRODUCT USED, IDENTIFY OF THE APPLICATOR; TIME AND DATE OF THE TREATMENT, SITE <br />~LOCATION, AREA TREATED, CHEMICAL USED, PERCENT CONCENTRATION AND NUMBER OF GALLONS USED TO ESTABLISH A VERIFIABLE RECORD OF <br />PROTECTION TREATMENT, fA PERMANENT SIGN VlHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE-INSPECTION AND TREATMENT <br />CONTRACT RENE\JAL SHAtI BE PROVIDED, THE SIGN SHALL BE POSTED NEAR THE \JATER HEATER DR ELECTRICAL PANEL, (FBC-104,2,7D <br /> <br />CONDENSATE AND ROOF DOVlNSPOUTS SHALL DISCHARGE AT LEAST 1'0" AVlAY FROM BUILDING SIDE \JALLS, IRRIGATION/SPRINKLER SYSTEMS INCLUDING <br />ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED wITHIN 1'011 OF THE BUILDING SIDE \JALLS, (FBC-1503AA) <br /> <br />GENERAL NOTES: <br /> <br />TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, VIALL COVERINGS SHALL NOT EXTEND TO VlITHIN 6 INCHES OF THE FINAL GRADE, <br />EXCEPTIONS: PAINT DR DECORATIVE CEMENTITIoUS FINISH NOT LESS THAN 5/811 THICK ADHERED DIRECTL Y TO THE FOUNDATION VIALL, (FBC-1403,1.6) <br /> <br />INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE, SOIL DISTURBED AFTER INITIAL TREATMENT SHALL BE <br />RETREATED INCLUDING SPACES BOXED AND FORMED, (FBC-1816.1,l) <br /> <br />SOIL DISTURBED AFTER INTIAL TREATMENT SHALL BE RE-TREATED INCLUDING SPACES BOXED DR FORMED, (FBC-1816,1.2) <br />BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALL TIoN OF TRAPS; ETC" SHALL BE MADE VlITH PERMANENT METAL OR PLASTIC FORMS, <br />PERMANENT FORMS MUST BE OF A SIZE DR DEPTH THAT VlILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT, <br />(FBC-1816,1.3) <br /> <br />MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION, IF RAINFALL OCCURS BEFORE VAPOR RETARDER <br />PLACEMENT; RETREATMENT IS REQUIRED, (FBC-1816.1A) <br /> <br />CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION VIALL MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, SOIL TREATMENT MUST BE <br />APPLIED UNDER ALL EXTERIOR CONCRETE DR GRADE VlITH 1'011 OF THE STRUCTURE SIDE\JALLS, (FBC-1816,1.5) <br /> <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION, ANY <br />SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED, (FBC-1816,1.6) <br /> <br />A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF <br />OCCUPANCY \JILL BE ISSUED, THE CERTIFICATE OF COMPLIANCE SHALL STATE: IIBUILDING HAS RECIEVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES, THE TREATMENT IS IN ACCORDANCE VlITH THE RULES AND LAVIS OF THE FLORIDA DEPARTMENT OF <br />AGRICUL TURE AND CONSUMER SERVICES,II <br />(FBC-1816,1.7) <br />TERMITE PROTECTION SHALL BE PROVIDED BY FLOOR FRAMIMG OF NATURALLY DURABLE VlOOD PRESERVATIVE TREATED VlOOD, SOIL TREATMENT DR <br />OTHER APPROVED METHODS, (FBC 2304.1,2) <br />PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLABS ON GRADE FLOORS SHALL NOT BE OF CELLULOSE - CONTAINING <br />MATERIALS AND SHALL RECEIVE APPLICATION OF A TERMITICIDE IN ANNULAR SPACE BETVlEEN SLEEVE AND PIPE, (FBC-2302,1.3) <br /> <br />AFTER ALL \JORK IS COMPLETED) LOOSE \JOOD AND FILL MUST BE REMOVED FROM BELO\J AND VlITHIN 1'011 OF THE BUILDING, THIS INCLUDES ALL <br />GRADE STAKES, TUB TRAP BOXES; FORMS, SHORING DR OTHER CELLULOSE CONTAINING MATERIAL, NO VlOOD, VEGATATION, STUMPS, CARDBOARD, TRASH, <br />ETC) SHALL BE BURIED VlITHIN 15'0' OF ANY BUILDING DR PROPOSED BUILDING, CFBC-2303.1.4) <br /> <br />\JINDOVl AND DOOR MANUFACTURERS TO PROVIDE CERTIFICATION/RATING THAT THEIR VlINDO\JS AND DOORS <br />\JILL VlITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING \JIND <br />PRESSURE AND PROVIDE INSTALLATION INFORMATION VlITH THEIR PRODUCTS, <br /> <br />CONTRACTOR TO INSTALL \JINDOVlS AND DOORS ACCORDING TO INSTRUCTIONS SUPPLIED BY MFGR AND HAVE <br />MAUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION FOR REVIEVI BY THE <br />BUILDING INSPECTOR, <br /> <br />ALL HURRICANE CLIPS) STRAPS AND FASTENERS ARE TO BE APPLIED ACCORDING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATIONS, IF DESIRED, EQUAL VENT CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOVlN, <br /> <br />FOUNDATION DESIGN BASIS: ASSUMED CAPACITY OF 2000PSF, CONTRACTOR TO VERIFY THAT SITE <br />CONDITIONS MEET THIS REQUIREMENT, <br /> <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS <br />CONNECTED COMPONENTS, PROVIDE ADEQUATE BRACING, SHORING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE \JORK, <br /> <br />CAST-IN-PLACE CONCRETE DESIGN AND CONTRUCTION STANDARD -- AMERICAN CONCRETE INSTITUTE, ACI 318-83 <br /> <br />NORMAL VlEIGHT REINFORCED CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH AS FOLLO\JS: <br />FOOTINGS AND SLAB GRADE_______ 3000 PSI <br />MASONTRY CELL FILL------------ 3000 PSI <br />ALL OTHER CONCRETE----------- 3000 PSI <br /> <br />REINFORCING STEEL SHALL CONFORM TO ASTM A-165) GRADE 40 MINIMUM, <br />LAP SPLICES VlHERE REQUIRED SHALL BE A MINIMUM OF 2511 FOR #5 REBAR, <br />30# FOR #6 REBAR AND 35" FOR #7 REBAR <br />VlELDED VlIRE FABRIC SHALL CONFORM TO ASTM A185, MINIMUM CONCRETE COVER FOR REINFORCING SHALL <br />BE AS FOLLOVlS, <br /> <br />Office <br />Copy <br /> <br />SOIL CONDITIONS: <br /> <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS, ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA <br />SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATEL Y SUPPORT 2000 P,S.F, FOUNDATION LOADING, <br />ALL CONTINUOUS VIALL FOOTINGS SLAB ON GRADE AREAS SHALL BE PROOF ROLLED, ALL SOFT SPOTS SHALL BE REMOVED AND REPLACED TO <br />FINISH GRADE VlITH APPROVED FILL MATERIAL, FILL MATERIAL SHALL BE PLACED IN 6# LAYERS MAX AND SHALL <br />BE COMPACTED TO A MINIMUM OF 95% OBTAINED BY ASTM D-1557, UNTIL FINAL GRADE IS OBTAINED, <br /> <br />FOOTINGS__________ 3" <br />COLUMNS___________ <br />FLOOR SLAB <br /> <br />1/2" FOR #5 AND SMALLER; 211 FOR ALL OTHER <br />1 1/2# FROM TOP OF SLAB <br /> <br />t~/A'''' ..., -j\ r..'VT I,) <br />.:: ,,-:z..')"" '.~) !.:"..... ~''-t d'.'~ <br />,. ..'.1-- ~---- ~~ v... <br />- -~ "-'" ''''f'')VDtL.~1!-)- ~ <br /> <br />SPLICES IN REINFORCING SHALL BE AS FOLLOVlS: <br />wELDED wIRE FABRIC_____ 811 <br />REINFORCING STEEL ALL BARS LAP MIN 25' <br /> <br />Office <br />Copy <br /> <br />DESIGN NOTES: <br />ALL CONSTRUCTION SHALL BE APPROVED IN ACCORDANCE VlITH FLORIDA BUILDING CODE) OSHA, AISC, AVIS D 1.1 CODES AND ALL <br />APPLICABLE LOCAL REQUIREMENTS, THE STRUCTURE IS DESIGNED TO COMPL Y VlITH THE 2001 FLORIDA BUILDING CODE, BUILDING BASE <br />CONNECTIONS SHALL BE PROVIDED AS SHO\JN, ALL MATERIALS IDENTIFIED BY MANUFACTURER NAME MAY BE SUBSTITUTED \JITH <br />MA TERIALS EQUAL DR EXCEEDING ORIGINAL RA TINGS, <br /> <br />.-. v.\..~ ::'n.u...L \..u.\ir L Y \\;lTH ALL <br />,:E: \ /\l..Ll\G CODES, r-WRlDA BU1LDll\G <br />l 01)[:, 0;A TlO~AL CLECTRlC CODE A.'\1) <br />CrTV OF ZEPHyR} ;lLLS ORDINA.J\CES <br /> <br />Office <br />(~py <br /> <br />ALL INFORMATION ON THIS PAGE IS INTENDED TO BE CORRECT BUT MISTAKES CAN BE MADE AND IT IS THE RESPONSIBILITY <br />OF THE CONTRACTOR TO VERIFY ALL INFORMA TION PRIOR TO CONSTRUCTION, <br /> <br />" <br /> <br />DQ vid W, SMith) P,E, <br /> <br />~ ~( <br />~ \~Ol <br />I. '}-'V <br /> <br />DAVID Cl\RR <br />DOGWOOD LANE <br /> <br />RICK GOLLHAROT - DRAFTSMAN <br /> <br />I hereby certify thO,t I hQ ve reviewed this plQn Qnd found it to be in <br />cOMplio'nce with section 1606 of the FloridQ Building Code) 2001 edition) <br /> <br />D . W . S M I rI" I-I , P . E . <br />FLORIDA PROFESSIONAL ENGINEER L[CENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 wALLASTON DRIVE-DADE CITY,FLORIDA 33525 <br />PHONE: 352...521-0865 FAX: 352-521-0867 E-I<1A[L: zephyr27@gte. net <br /> <br />ENGINEER NOTES <br />STANDARD NOTES <br /> <br />SHEET OF <br /> <br />1 OF 12 <br /> <br />SCALE <br /> <br />DATE <br /> <br />JOB NO. <br /> <br />21 FEB 2005 <br /> <br />ENGINEER LICENCE U53608 <br /> <br />CARR CONSTRUCTION, INC <br /> <br />DESIGN/DRAWN CHECKED <br />R. GOLLHARDT D.W.SMITH,P.E, <br /> <br />2005-17 <br />