Laserfiche WebLink
<br />S TRUe TURAL NOTES <br /> <br />COMPONENT ~ CLADDING DESIGN PRESSURE <br />(120 MPH, 3 SEC. 6IJST, 2.1/12 TO 6.'1/12 PITCH, EXPOSURE B, IMPORTANCE FACTOR=I) <br />(PSF ) <br /> <br />10 <br /> <br />20 <br /> <br />50 <br /> <br />100 <br /> <br />125 <br /> <br />NOTES: I FOR EFFECTIVE AREAS OR HIND SPEEDS BETHEEN THOSE GIVEN ABOVE, THE <br />LOAD MAY BE INTERPOLATED, OTHERY-lISE USE THE LOAD ASSOCIATED HITH <br />THE LOHER EFFECTIVE AREA. <br /> <br />2 TABLE VALUES SHALL BE ADJUSTED FOR HEIGHT AND EXPOSURE BY <br />MULTIPLYING BY ADJUSTMENT COEFFICIENTS IN TABLE 1606.2D OF THE FLORIDA <br />BUILDING CODE 2001, <br /> <br />3 PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOHA-RD AND AHA-Y FROM <br />THE BUILDING SURFACES. <br /> <br />TRIBUTARY AREA <br />(FT2) <br /> <br />REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />(RE: FBC 2405.2.1) <br /> <br />2405.1 6eneral. Individual glazed areas Inc.ludln9 glass mIrrors in hazardous loc.atlons <br />suc.h as those Indlc.ated In 2405.2 sholl poss the test requirements of CPSC 16-GFR, <br />Part 1201 or by c.omparatlve test shall be proven to produc.e or least equivalent performances. <br /> <br />Exceptlonsl <br />I. Polished wire glass Installed in rlre doors, rire windows and view panels In rlre resistant <br />Nalls and hazardous locations In 2405.2.1(3) and 2405.2.1(4) sholl comply Nlth ANSI zerr.l. <br />2. Approved plastic materials used as glazing in hazardous locotlons sholl comply Nlth ANSI Zerr.l, <br /> <br />2405.2 Hazardous Locations <br />2405.2.1 The rollowlng shall be considered SpeC.lrlC hazardous locations for the purpose <br /> <br />Or glazing: <br /> <br />I, <br /> <br />61azin9 in sNln91n9 doors and rlxed and sliding panels of sliding <br />(patio) door assemblies. <br /> <br /> ROOF HA-LL <br /> (GCpl = +1- 18) (GCpl = +/- 18) <br />14.'1 -50.1 25.cr -34.1 <br />13.0 -45.4 24.1 -32.4 <br />II.cr -3'1.3 23.2 -2'1,3 <br />10.5 -34.1 22.0 -26,'1 <br />10.5 -34.1 21.1 -26.2 <br /> <br />2. <br /> <br />61azinq In doors and Holls or enclosures ror hot tubs, Nhlrloools, <br />saunaS-; steam rooms, bathtubs, showers ClIJd othC(r suc.h racllitles <br />Nhere such qlazlnQ is located 36 Inches ('114 mm) or less, <br />measured hc>rlzonrally, from a standing or wolkln9 surface Nlthln <br /> <br />the enc.losure and Nhere the bottom edqe or the exposed 91azing IS <br />less than 60 Inches (1524 mm), measurecfvedlcally, above SIKh <br />standing or Nalkln9 surfac.e. <br /> <br />PRECAST LINTEL <br />SAFE GRAVITY LOAD TABLE <br /> <br />LENG TH <br /> <br />3. <br /> <br />Glazing in an Individual rixed or operable panel adrac.ent to a door <br />Nhere the neorest vertlcol edge Is within a 24-ln& (610 mm) <br />radius of the door In 0 closed position and whose bottom edge 15 <br />less. than 60 Inches (1524 mm) above the floor or walking svrtace. <br /> <br />2'-10" (34") PRECAST <br />3'-6" (42") PRECAST <br />4' -0" (48") PRECAST <br />4'-6" (54") PRECAST <br />5'-4" (64") PRECAST <br />5'-10"(64") PRECAST <br />6'-6" (78") PRECAST <br />7'-6" (90") PRECAST <br />9'-4" (112") PRECAST <br />10'-6" (126") PRECAST <br />1" -4" (136") PRECAST <br />1 2' - 0" (144") PRECAST <br />13'-4" (160") PRECAST <br />14'-0" (168") PRECAST <br />14-'-8" (176") PRE STRESSED <br />15'-4" (184") PRE STRESSED <br />1 7' -4" (206") PRE STRESSED <br />19'-4" (232") PRE STRESSED <br />21' -4" (252") PRE STRESSED <br />22'-0" (264") PRE STRESSED <br />24' -0" (288") PRE STRESSED <br /> <br />Exception: <br />I. 610zlnq in walls perpendlc.vlar to the plane of the door in a closed positIon In 6roup R3 <br />or NitFiln dwellln9 units In 6roup R2 sholl be subject to 2405.2.1(4). <br /> <br />Glazlnq in an IndIvidual f'lxed or op,eroble oanel, other thon those <br />10catlO'ns described In Items 2 an(1 3 above, thot meets all of the <br />rollowlng conditions: <br />4.1 Exposea are2a of an Individual pane greater than cr sq. ft. <br />(0.84.m ) <br />Bottom edge less thon 18 inches. (451 mm) obove the floor. <br />Top edge greater than 36 Inc.hes ('114 mm) above the rloor. <br />One or more Nolklng surfac.es Nlthln 36 Inc.hes ('114 mm) <br />horlzontall~ of the plane of the glazing. <br /> <br />4. <br /> <br />4.2 <br />4.3 <br />4.4 <br /> <br />5. All glazln9 in rallln9S re90rdless or area or height above a Holklng <br />surfoces Inc.ludln9 structural baluster ponels ond non structural In- <br />1'1115 panels.. <br /> <br />6, Glazln9 in Nal!s and rences enclosin9 Indoor and outdoor sNimmin9 pools and <br />spas Nhere the bottom exposed edge of the glazing IS: (I) less than 60 Inc.hes <br />(1525 mm) above the Holklng sudac.e on the pool side or the 9lazln9, and (2) <br />the glazing Is within 60 Inc.hes (1525 mm) horlzof"ltolly of the woler's edge of a <br />swimmin9 pool or spa. This sholl apply to Single glazing and all panes. In <br />multiple glazing, <br /> <br />SAFE LOAD - POUNDS PER LINEAR FOOT <br />UNFILLED FILLED <br /> <br />2302 <br />2302 <br />2,029 <br />1,624 <br />1,184 <br />972 <br />937 <br />767 <br />573 <br />456 <br />445 <br />414 <br />362 <br />338 <br />N.R. <br />N,R. <br />N.R. <br />N.R. <br />N.R. <br />N.R. <br />N.R. <br /> <br />6,861 <br />6,039 <br />4,657 <br />3,662 <br />3,241 <br />2,718 <br />2,332 <br />2,040 <br />1,529 <br />1,392 <br />1,234 <br />1,140 <br />1,073 <br />1,003 <br />1,370 <br />1,203 <br />950 <br />750 <br />610 <br />570 <br />470 <br /> <br />~ SAFE LOAD VALUES ARE BASED ON MANUFACTURER'S CALCULAllONS. <br />~ PRECAST LINTELS MAY BE SUPPLIED ONLY BY APPROVED <br />PRECAST MANUFACTURERS. (SEE SECT 4.3) <br />~ FILLED LOAD VALUES ASSUME A MINIMUM 8" CONCRETE FILLEq KNOCK-OUT BLOCK ABOVE <br />THE PRECAST LINTEL AND ONE #5 BAR IN THE LINTEL. <br /> <br />, 0- <br />, :c <br />, <br />, >- <br />.0 <br />, <br />, -'" <br />CCJ <br />, cD <br />"0 <br />o <br />,- <br />:2 <br />-< <br /> <br />, <br />... <br /> <br />o <br /> <br />, <br />, , <br /> <br />, en <br />, <br />. <br /> <br />~~ <br />, <br /> <br />, CCJ <br />'cD <br />,() <br /> <br />> <br />'cD <br />"0 <br />iN <br />- <br />~ <br />I~ <br />, I <br />10- <br />:c <br /> <br />, "0 <br />,... <br />'aJ <br />-'" <br />() <br />cxs <br />0- <br />I <br />- <br />- <br />cD <br />,. <br />cD <br />:c <br /> <br />C8 <br />C8 <br />IX) <br /> <br />- <br />cD <br />-:) <br />c:: <br />a <br /> <br />CCJ <br />cD <br />o <br /> <br />0- <br />X <br /> <br />A) <br /> <br />B) <br /> <br />C) <br />D) <br /> <br />GLASS BLOCK INSTALLAllON PERFORMED IN ACCORDANCE \'VIlli FBC <br /> <br />COVER SILL AREA \'VIlli A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br /> <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br /> <br />SET A FULL MORTAR BED JOINT, APPLiED TO SILL. <br /> <br />SET LO\^IER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURRO\^IED. ALL MORTAR SHALL BE <br />TYPE "s" OR "N". SlEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSmON, (PLACE <br />A RUBBER CRUTCH llP ON END OF TROWEL TO TAP BLOCK INTO POSmON.) DO NOT <br />REALiGN, TAP, OR OlliERWISE MOVE BLOCK AFTER INlllAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br /> <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIAlELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (lliE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONllNUOUSL Y FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS Willi REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br /> <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br /> <br />* PRESS PANEL REINFORCING INTO PLACE. <br /> <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TRO\^IEL <br />SMOOlli. DO NO FURROW, <br /> <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br /> <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR. <br /> <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS SllLL PLASllC AND BEFORE FINAL SET. AT THIS <br />llME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />\^lEDGES FROM LO\^IER COURSES OF SOLID BLOCKS AND POINT 111E VOIDS \'VI111 MORTAR.) <br /> <br />6' MIN, <br />LAP SPLICE <br />NOTE. <br />SEE GLASS BLOCK <br />INST ALLA nON NOTES, <br />GLASS 6LOCK DETAIL <br /> <br />I) <br />J) <br />K) <br /> <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING llGHTL Y BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUC1l0N. LEAVE SPACE FOR SEALiNG. <br /> <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLiCA1l0N MANUAL AND INSTRUC1l0NS. <br /> <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*. PER PITTSBURG CORNING RECOMMENDA 1l0NS FOR <br />INSTALLA1l0N OF GLASS BLOCK. <br /> <br />20 go., PANEL <br />ANCHOR <br /> <br />~EXPANSICN STRIP <br /> <br /> <br />~ANSICN <br />BOL T (2 PER <br />ANCHOR) <br /> <br />E) <br /> <br />9 go., PANEL <br />REINFORCING <br />(EVERY OTHER <br />COURSE) <br /> <br />~ <br />.,~. <br />I p: . '.' ...::~nnn <br />~::::::~ .' f" .::::....::: <br />:::::. ':.~::::: .'. ':.-:::: :.:::::::::. <br /> <br />~l\\\\\I..;;i:~iiH~~~ ~~~~t~~~~:l~ l~::::" <br />/ ~m~~~m~m~m~~ ~n::::" <br />~m~l~~~~lli ~~~~::.. <br />:::::~ <br />~ -SEALANT <br />l.- <br /> <br />~XPANSlON STRIP <br />~SEALANT <br /> <br />6' MIN, <br />LAP SPLICE <br />\I / REINFORCING <br />PANEL <br /> <br />F) <br /> <br />G) <br />H) <br /> <br />* (110mph FASlEST WlND= 130MPH, 3 SEC. GUST. FBC TABLE 1606.1.6.1) <br /> <br />ROOF DIAPHRAGM NAILING SCHEDULE <br /> <br />oJ <br /> <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />+ <br /> <br />RIDGE LINE <br /> <br />+ + + + + + + + +~ <br />+ + + + + + + + 0 <br />+ + + + + + + + +_1 <br />+ + + + + + + + ~ <br /> <br />+ + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br /> <br />-".J <br /> <br />+ <br />+ + <br />+ <br />+ + <br />+ <br /> <br />/~ 6'~0' (TYP.) ,;-0: <br /> <br />/ :::' :::~ ::: <br /> <br />+ + + + + + <br />+ <br />+ + + + ~+ + + ~ + + + + + + .~+ + + + + + + <br />+++++ ++ 9 +++++++ +++++ + <br />+++++ +++<.0 +-t+++++ +++++++ <br />... ... + + + + +'-+ + + + + + ~ + <br />" "--RIDGE LINE <br />120 MPH 3 SECOND GUST EXPOSURE "8" WIND ZONE 120 MPH 3 SECOND GUST EXPOSURE "8" WIND ZONE <br />8d COMMON NAILS @ 6" O.C, &: 8d COMMON NAILS @ 6" a.c. EDGES &: <br />4" a.c. @ GABLE END WAll OR GABLE TRUSS Sd COMMON NAILS @ 12" O.C. INTERMEDIATE <br />.131~X2 1/t LONG GUNNAIL @ 4" O,C, .131~X2 1/2" LONG GUNNAIL @ 4" O.C. <br />.120~X3" LONG GUNNAIL @ 4" O,C. EDGES &: 8" O.C. INTERMEDIATE <br />.113~Xt LON"G GUNNAIL @ 3" O,C~ .1200X3" LONG GUNNAIL @ 4" O.C. <br />.099~X2 1/4 LONG GUNNAIL @ 3 O,C. EDGES &: 8" a.c, INTERMEDIATE <br />.113~X2" LONG GUNNAIL @ 3" O.C. EDGES <br />(STAGGERED) &: S" a.c. INTERMEDIATE <br />.099~X2 1/4" LONG GUNNAIL @ 3" O.C. <br />EDGES &: 6" O.C. INTERMEDIATE <br /> <br />6'-0. <br />/ <br /> <br />+ <br />+ + <br />+ <br />~ + + <br />co + <br /><3 + + <br />+ <br />+ + <br />+ <br />+ + <br /> <br />~ <br />~ <br /> <br />D <br /> <br />NOTE: 1) SEE STRVClURAL NOTES FOR SHEATI1ING SPECIFICATIONS AND 'MND SPEED. <br />2) END JOINTS OF TI1E ROOF SHEATI1ING SHALL <br />BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEA TI1ING IS FASTENED DIREC'll Y TO SOUTI1ERN YELLOW PINE OR DOUGlAS <br />FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE Of LUMBER, CONTRACTOR MUST <br />CONTACT DANSCO ENGINEERING, P.A. FOR ALTERNATE FOR NAIUNG PATIIRN. <br /> <br />D 5AMUEL A. GREENBERG, P.E. #34245 <br />D Tl-+UY H. l-+UYNH P.E. -60122 <br />D IRWIN J. BEN50N, F.E. #4~158 <br />D All AB6A5 l-+AKIM, P.E. *'56186 <br /> <br />TO TI4E BE5T OF TI4E ENGINEER'5 KNOUJLED6E AND BELIEF, TI4E <br />5TRUCTURAL PLAN5 AND 5PECIFICATION5 COMPL Y WIT~ TI4E <br />FLORIDA BUILDING CODE, &ECTION 16>06> FOR 120 MP~:3 &ECOND <br />GU5T, EXPOOURE '6' WIND ZONE (2001 EDITION). <br />T~15 DRAWING AND DE51GN 15 VALID FOR 12 MONm5 AFTER THE <br />DATE IT 15 51GNED AND OEALED. <br />51GNED AND OEALED FOR TI4E 5TRUCTURAL PORTION OF T~15 <br />DRAWING ONLY. <br /> <br />r <br /> <br />DE <br /> <br />""\ <br /> <br />D ANSCO <br />ENGINEERING, FA.. <br />p.o. eox 3400 - APOLLO 6EAC14 - FLORIDA - 33&12 <br />~ - (813) 64& 0166 FAX - (813) 64& ~ca& <br /> <br />Em. ..lalA\ r'C\ IHESE DRA\\lNGS AND DESIGNS ARE IHE JOINT PROPERTY Of DANSCO ENGINEERING, P.A, AND IHE <br />-' ~ -- ~CUENT ON IHIS PRO.f:CT. ANY REPRODUCTION OR UNAUIHORIZED USE IS PROHIBITED. - 2003 <br /> <br />~ CREATED 01-02-02 <br /> <br />3 <br /> <br />120 <br />SEC. <br /> <br />&EAt. ""'" <br />\ ecAJ..E NOTED <br />DATE 112/02 <br /> <br />TAr1PA Olvf6fON <br /> <br />DRAlLN BV. <br />N:/8LOCKS/STD 2001 <br /> <br />MPH <br />GUST <br /> <br />LENNAR ~OMEe <br /> <br />NOTE: <br /> <br />IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWlNGS BEFORE CONSTRUCTION <br />BEGINS. DANSCO ENGINEERING P.A. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS <br />PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' <br />SHOP DRAWlNGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED <br />DRAWlNGS MUST BE BROUGHT TO THE ATTENllON OF DANSCO ENGINEERING P.A. PRIOR TO <br />THE COMMENCEMENT OF CONSTRUCllON. <br /> <br />"- <br /> <br />"'-- <br /> <br />eTRUCTURAL NOTSe 4 T ASLE5 <br /> <br />DE JOB NO. PM - 512>21 <br /> <br />eN2 <br /> <br />~ <br /> <br />l' <br />