<br />S TRUe TURAL NOTES <br /> <br />GLASS BLOCK INSTALLATION PERFORMED IN ACCORDANCE WIlli mc <br /> <br />A) COVER SILL AREA WIlli A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br /> <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br /> <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br /> <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/B" PLUS OR MINUS <br />1/B". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "s" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO PosmON. (PLACE <br />A RUBBER CRUTCH llP ON END OF TROWEL TO TAP BLOCK INTO PosmON.) DO NOT <br />REALIGN, TAP, OR OlliERWlSE MOVE BLOCK AFlER INITlAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN lliE MORTAR JOINTS OF lliE LOWER <br />COURSES TO PREVENT lliE MORTAR FROM BEING "SQUEEZED" OUT. <br /> <br />E) INSTALL PANEL REINFORCING IN EVERY OlliER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WlllilN PANELS. (lliE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONllNUOUSL Y FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS lliAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />lliAN ONE LENGlli. DO NOT BRIDGE EXPANSION JOINTS WIlli REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br /> <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br /> <br />* PRESS PANEL REINFORCING INTO PLACE. <br /> <br />* COVER PANEL REINFORCING WIlli UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOlli. DO NO FURROW. <br /> <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAiN UNIFORM JOINT WlDlli. <br /> <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR. <br /> <br />H) STRIKE JOINTS SMOOlli WHILE MORTAR IS SllLL PLASllC AND BEFORE FINAL SET. AT llilS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPlli EQUAL TO lliE WlDlli OF lliE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />TOOL JOINTS SMOOlli AND CONCAVE. BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT lliE VOIDS WIlli MORTAR.) <br /> <br />COMPONENT ~ CLADDING DESIGN PRESSURE <br />(120 HPH,3 SEC, GUST, 2.1/12 TO 0.<1/12 PITCH, EXPOSURE B, IMPORTANCE FACTOR=!) <br />(PSF ) <br /> <br />TRIBUTARY AREA <br />(FT') <br /> <br /> ROOF HALL <br /> (GCpl = +/- 18) (GCpl = +/- 18) <br />14.<1 -50.1 25.<1 -34.1 <br />13.0 -45.4 24.1 -32.4 <br />11.<1 -3<1.3 232 -2<1.3 <br />105 -34.1 22,0 -20.<1 <br />105 -34,1 21.1 -20.2 <br /> <br />REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />(RE: FBC 2405.2.1) <br /> <br />10 <br /> <br />2405.1 6enerol. IncHvldvol glozed oreos Inclvdlng gloss mIrrors In hozor-dovs locotlons <br />svch os those Indlcoted In 2405.2 sholl pos:; the test reqvir-ements of CPSG lo-CFR, <br />Por-t 1201 or bl;j comporotlve te:;t :;holl be proven to prodvce or- leost eqvlvolent performonce:;, <br /> <br />20 <br />50 <br /> <br />100 <br /> <br />Exceptions: <br />I. Polished Hire gloss instolled In fIre doors, fire HindoHS ond vleH ponels In fire reslstont <br />Holls ond hozordovs locotlons in 2405.2.1(3) ond 2405.2,1(4) sholl compll;j Hlth ANSI ZCf7.I. <br />2. Approved pl05tlc moterlols vsed os glozing In hazordov:; locations :;holl corrpll;j Hith ANSI ZCf7.I. <br /> <br />125 <br /> <br />NOITS: I FOR EFFECTIVE AREAS OR HIND SPEEDS BETWEEN THOSE 61VEN ABOVE, THE <br />LOAD HAY BE INITRPOLAITD, OTHERWISE USE THE LOAD ASSOCIAITD HITH <br />THE LOY'iER EFFECTIVE AREA. <br /> <br />2 TABLE VALUES SHALL BE ADJlJSITD FOR HEI6HT AND EXPOSURE BY <br />HLJLTIPL YIN6 BY ADJlJSTI-1ENT COEFFICIENTS IN TABLE 1000.2D OF THE FLORIDA <br />BUILDIN6 CODE 2001. <br /> <br />3 PLUS AND HINUS SI6NS SI6NIFY PRESSURES ACTIN6 TOHARD AND AHAY FROH <br />THE BUILDIN6 SURFACES. <br /> <br />2405.2 Hazardou:; Locations <br />2405.2.1 11Ie folloHlng :;holl be considered specific hozor-dovs locotlons for the purpose <br /> <br />of glozing: <br /> <br />I. <br /> <br />610zing in SHlnglng doors ond fixed ond sliding ponels of sliding <br />(potlo) door os:;emblle:;. <br /> <br />2. <br /> <br />610zlnq in doors ond Holl:; of enclosure:; for hot tvbs, HhlrIQool:;, <br />souno:;; steom rooms, bothtvbs, shoHers qrJd other svch foc,llltles <br />Hhere such qlozln.;::1 Is locoted 30 inc,hes ('114 mm) or les:;, <br />measured hO'rrzont"oll~, from 0 :;tondlng or Holklng :;vrfoce Hlthin <br /> <br />the enclosvre ond Hhere the bottom edqe of the exposed glozing Is <br />less thon 00 Inches (1524 mm), meosvrecf vertlc,olll;j, obove :;uc,h <br />:;tandlng or Holklng svrfoce, <br /> <br />PRECAST LINTEL <br />SAFE GRAVITY LOAD TABLE <br /> <br />,f <br /> <br />I) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING llGHTL Y BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCllON. LEAVE SPACE FOR SEALING. <br /> <br />J) APPLY SEALANT EVENLY TO lliE FULL DEPTH OF RECESSES IN ACCORDANCE WIlli lliE <br />MANUFACTURER'S APPLlCAllON MANUAL AND INSTRUCllONS. <br /> <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PIITSBURG CORNING RECOMMENDAll0NS FOR <br />INSTALLAll0N OF GLASS BLOCK. <br /> <br />~EXPANSIDN STRIP <br />20 gOo. PANEL <br />ANCROR <br /> <br />9 go., PANEL ~1/4' EXPANSION <br />REINFORCING <br />(EVERY OTHER ~ jl BOL T (2 PER <br /> <br />CO:E> ~ ~ ~::::ION STRIP <br />~:::::~ ...... :::::::.::::: VXSEALANT <br />:;:::'.':.,:;,; .. '-:.";: ..:,:,,;:,:. ~ <br /> <br />6' MIN, <br />LAP SPLICE <br />'oJ I REINFORCING <br />~~~~~~~~~} ::::.. E~pMlrPLICE PANEL <br />r -SEALANT NOTE. <br />~ SEE GLASS BLOCK <br />INST ALLA TION NOTES. <br />GLASS BLOCK DETAIL <br /> <br />* (110mph FASTEST WIND= 130MPH, 3 SEC. GUST. FBC TABLE 1606.1,6,1) <br /> <br />RIDGE LI N E <br /> <br />ROOF DIAPHRAGM NAILING SCHEDULE <br /> <br />! ~ 6'-0" (TYP.) <br /> <br />/~+;+++'5~ <br />+ + + + <br />+ . + -+ <br />+ + + + <br />+ +-+ <br />+ + + + <br />+ + + + + + ~.+ + + + + <br />+-++++++ +++++ <br />+++++++ +++++ <br />+ + '-+ + + + + + "- <br />'-RIDGE UNE <br />120 MPH 3 SECOND GUST EXPOSURE "S" WIND ZONE 120 MPH 3 SECOND GUST EXPOSURE "S" WIND ZONE <br />8d COMMON NAILS @ 6" O.C. & 8d COMMON NAILS @ 6" O.C. EDGES & <br />4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d COMMON NAILS @ 1t O.C. INTERMEDIATE <br />,131~X2 }/2" LONG GUNNAIL"@ 4" O.C. .131~X2 1/t LONG GUNNAIL @ 4" O.C. <br />,1200X3" LONG GUNNAIL @ 4 O.C, EDGES & 8" O.C. INTERMEDIATE <br />.1130X2 LO~G GUNNAIL @ 3" O.C~ .1200X3" LONG GUNNAIL @ 4" O.C. <br />.0990X2 1/4 LONG GUNNAIL @ 3 O.C. EDGES & 8" O.C. INTERMEDIATE <br />.1130X2" LONG GUNNAIL @ 3" O.C. EDGES <br />(STAGGERED) & 8" O.C. INTERMEDIATE <br />.0990X2 1/4" LONG GUNNAIL @ 3" O.C. <br />EDGES & 6" a.c. INTERMEDIA IT <br /> <br />SAFE LOAD - POUNDS PER LINEAR FOOT <br />UNFILLED FILLED <br /> <br />C:::-Y <br /> <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />+ <br /> <br />, <br />+ + + + + + + + += <br />+ + + + + + + + 0 <br />+ + + + + + + + +_1 <br />+ + + + + + + + ~ <br /> <br />LENGTH <br /> <br />3. <br /> <br />610zlng in on indlvlduol fixed or operoble pone I od loc,ent to 0 door <br />Hhere the neorest vertlc-ol edge Is Hithln 0 24-lnl1n (010 mm) <br />rodlus of the door In a clo:;ed pOSition ond Hhose bottom edqe Is <br />les:; thon 00 Inche:; (1524 mm) obove the floor or Hoiking surfoce. <br /> <br />6,861 <br />6,039 <br />4,657 <br />3,662 <br />3,241 <br />2,718 <br />2,332 <br />2,040 <br />1,529 <br />1,392 <br />1,234 <br />1,140 <br />1,073 <br />1,003 <br />1,370 <br />1,203 <br />950 <br />750 <br />610 <br />570 <br />470 <br /> <br />2'-10"' (34") PRECAST <br />3'-6" (42") PRECAST <br />4'-0" (48") PRECAST <br />4'-6" (54") PRECAST <br />5'-4" (64") PRECAST <br />5'-10"(64") PRECAST <br />6'-6" (78") PRECAST <br />7'-6" (90") PRECAST <br />9'-4" (112") PRECAST <br />10'-6" (126") PRECAST <br />11'-4" (136") PRECAST <br />12' - 0" (144") PRECAST <br />13' - 4" (160") PRECAST <br />14'-0" (168") PRECAST <br />14'-8" (176") PRE STRESSED <br />15'-4" (184") PRE STRESSED <br />17' - 4" (206") PRE STRESSED <br />19'-4" (232") PRE STRESSED <br />21'-4" (252") PRE STRESSED <br />22'-0" (264") PRE STRESSED <br />24'-0" (288") PRE STRESSED <br /> <br />2302 <br />2302 <br />2,029 <br />1,624 <br />1,184 <br />972 <br />937 <br />767 <br />573 <br />456 <br />445 <br />414 <br />362 <br />338 <br />N.R. <br />N.R. <br />N.R, <br />N.R. <br />N.R, <br />N.R. <br />N.R, <br /> <br />/ <br /> <br />6'-0" / <br />/ <br /> <br />Exception: <br />I. 610zinq in Holls perpendicvlor to the plone of the door In 0 closed pOSition in 6rOvp R3 <br />or Hitnln dHelllng vnits in 6rovp R2 :;noll be :;vbJec,t to 2405.2.1(4). <br /> <br />+ <br />+ + <br />+ <br />:::J + + <br />ro + <br /><3 + + <br />+ <br />+ + <br />+ <br />+ + <br /> <br />++++~+ ++= <br />+++++ ++ 9 <br />+++++ +++<.0 <br />.L. .L. + + + <br /> <br />4 610zlnq In on indlvldvol fixed or oseroble Qonel, other thon those <br />. locotlO'ns de:;G,('lbed In Items 2 on(;j 3 obove, thot meet:; 011 of the <br />folloHlng conditIons: <br />4,1 Exposea or-eo of on Indlvldvol pone greoter thon <1 sq. ft. <br />(O,84.m ) 2 <br />4.2 Bottom edge less thon 18 Inc.he:; (451 mm) obove the floor. <br />4.3 Top edge greoter thon 30 inc,he:; (<114 mm) obove the floor. <br />4.4 One or more Holkfng :;urfoces Hlthln 30 Inc,he:; (<114 mm) <br />horlzontolll;j of the plone of the glozing. <br /> <br />5. All glOZing In rollings regard Ie:;:; of DreG or height obove 0 Holklng <br />:;urfoces Inclvdlng :;trvcturol bolv:;ter panels ond non :;trvctllral In- <br />fill:; ponels. <br /> <br />~ <br />~ <br /> <br />o. 61azing In Holls OM fence:; enclosing Indoor and outdoor :;Hlmming pool:; ond <br />spas Hhere the bottom expo:;ed edge of the glozing Is: (I) Ie:;:; thon 00 Inche:; <br />(1525 mm) obove the Holklng svrfoce on the pool :;Ide of the glozing, ond (2) <br />the glOZing Is Hithln 00 inches (1525 mm) horizontoll'~ of the HOter':; edge of 0 <br />SHimming pool or spo. 11Iis sholl oppll;j to :;Ingle glozing ond 011 pone:; In <br />mvltlple glozing. <br /> <br />~ <br /> <br />+ + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br /> <br />+ <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br /> <br />/ <br /> <br />6' -0" / <br />/ <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />+ <br /> <br />D <br /> <br />~ SAFE LOAD VALUES ARE BASED ON MANUFACTURER'S CALCULAllONS. <br />~ PRECAST LINTELS MAYBE SUPPLIED ONLY BY APPROVED <br />PRECAST MANUFACTURERS. (SEE SECT 4.3) <br />~ FiLLED LOAD VALUES ASSUME A MINIMUM 8" CONCRETE FILLED KNOCK-OUT BLOCK ABOVE <br />THE PRECAST LINTEL AND ONE #5 BAR IN THE LINTEL. <br /> <br />NOTE: 1) SEE STRUC11JRAl NOTES FOR SHEATl1ING SPEClflCAllONS AND I'l\ND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL <br />BE STAGGERED AND OCCUR ovm FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEA Tl1ING IS FASTENED DIRECn. Y TO SOUTHERN YELLOW PINE OR DOUGlAS <br />FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE Of LUMBER, CONTRACTOR MUST <br />CONTACT DANSCO ENGINEERING, P.A. FOR ALTERNATE FOR NAIUNG PATTERN. <br /> <br />IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAW1NGS BEFORE CONSTRUCllON <br />BEGINS. DANSCO ENGINEERiNG P.A. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS <br />PROJECT ONLY. ANY DISCREP ANCY Bm~EN FIELD CONDIllONS, 01HER DESIGN PROFESSIONALS' <br />SHOP DRAW1NGS, CONTRACTORS' BUILDING METHODS, AND 1HESE SIGNED AND SEALED <br />DRAWINGS MUST BE BROUGHT TO THE A TIENllON OF DANSCO ENGINEERING P.A. PRIOR TO <br />1HE COMMENCEMENT OF CONSTRUCTION. <br /> <br />~ <br />c <br />:::a <br />~o.. <br />D::C <br />D <br />" >- <br /> .0 <br />iii <br />O~ <br />.. ClO <br />0 CD <br />- "Q <br />.. 0 <br />~ - <br />- ~ <br /> < <br />0 <br />- .... <br /> 0 <br />ooJ - <br />~ <br />:) , <br />~ C':) <br />~ - <br />= -or <br />i'!;l <br />::J <br />" ClO <br />i!: CD <br />" Co) <br />-- > <br />..A CD <br />- "Q <br />f C'.I <br />l.. - <br />. -J <br />uC' <br />..A , <br />!'o.. <br />l!:::C <br />~ "Q <br />~ .... <br />ClO <br />l..~ <br />~ Co) <br />ca <br />- 0.. <br />- . <br />c - <br />:( - <br />i!:: CD <br />i!::- <br />u ~ <br />..I CD <br />-x <br />iii NOTE: <br />iii dI>> <br />" CSt <br /> QO <br />:::a <br />- ... <br />~ CD <br />- ~ <br />~ c <br />" ell <br />s-; <br />..A CD <br />00 <br />- <br />"0.. <br />!:::c <br /> <br />D 5AMUEL A. GREEN6ERG, P.E. ~424:; <br />D Tl-iUY l-i. l-iU'YNH P.E. ~0122 <br />D IRWIN J. 6EN50N, P.E. #4~l:;8 <br />D All A66A5 l-iAKIM, PJ:. lI5bl8b <br /> <br />TO TI-IE 6EeT OF TI-IE ENGINEER'e KNOJ)LEDGE AND 6ELlEF, TI-tE <br />eTRUCTURAL pL.ANe AND ePECIFICATIONe COMPL Y wm~ TI-IE <br />FLORIDA 6UILDING CODE, OECTION !~e>~ FOR 12e> MP~ 3 OECOND <br />OOeT, EXPOOURE '6' WIND ZONE (2001 EDITION). <br />T~le DRAWING AND DEelGN Ie vALID FOR 12 MONT~e AFTER TI-IE <br />DATE IT Ie elGNED AND OEAL.ED. <br />elGNED AND eEALED FOR T~E eTRUCTURAL PORTION OF T~le <br />DRAWING ONLY. <br /> <br />r <br /> <br />DE <br /> <br />"' <br /> <br />D A~l5CO <br /> <br />ENGINEERING, FA. <br />P.o.60X 3400 - APOLLO eEAC44 - R.~IDA - 33&12 <br />Ft-lONE - (813) 64& ~166 FAX - (813) 64& <a6<a8 <br />e6 4&t~ f(\ TIjESE DRA'MNGS AND DESIGNS ARE TIjE JOINT PROPERTY OF DANSCO ENGINEERING, P.A. AND TIjE <br />~ClJENT ON 1111$ PROJECT. ANY REPROOlJC1lON OR UNAU1110RIZED USE IS PROHIBITED. - 2003 <br /> <br />~ CREATED 01-02-02 <br /> <br />3 <br /> <br />120 <br />SEC. <br /> <br />MPH <br />GUST <br /> <br />&EAL""" <br />\ 8CALE NOTED <br />DATE 112/02 <br /> <br />LENNAR f.40ME6 <br /> <br />TAMPA DivISION <br /> <br />D~ av. <br />N:/BLOCKS/STO 2001 <br /> <br />"'- <br /> <br />6TRUCTURAL NOTE5 4 T A6LE5 <br /> <br />DE Joe NO. PM - 5021 <br /> <br />eN2 <br /> <br />\... <br /> <br />~ <br />