<br />FIGURE 1: FLASHING INSTAllATION
<br />
<br />\./ALL SHEATHING ~
<br />
<br />
<br />ASPHAL T SEALANT:
<br />EXTEND MIN, OF 611
<br />OUTSIDE OF FLASHING
<br />
<br />
<br />RICKET AS
<br />SPECIFIED
<br />BY PLAN
<br />
<br />FLASHING INSTAllATION
<br />~HERE ROOF MEETS VERTICAL ~ALL
<br />
<br />GAL V, MTL,
<br />ILl FLASHING
<br />
<br />'"
<br />'.D
<br />:z
<br />~
<br />L
<br />
<br />DDF SHINGLES
<br />
<br />ROOF CRICKET:
<br />MIN: 3:12 SLOPE
<br />(REQUIRED AT
<br />ALL LEVEL VALLEY
<br />LOCA TIONS)
<br />
<br />
<br />VERTICAL ~ALL
<br />AT ENTRY
<br />
<br />TEXTURED, PAINTED
<br />EXTER, ~F\LL FINISH
<br />6' X 18' H GAL V,
<br />FLASHING CONT,
<br />PLASTER STOP.
<br />ROOF
<br />SHINGLES
<br />
<br />ASPHALT BASED
<br />SEALANT APPLIED
<br />BEHIND FLASHING
<br />AND EXTENDING A
<br />MINIMUM OF 6' ABOVE
<br />VERTICAL RISE OF FLASHING
<br />AT KNEE~ALL
<br />
<br />6' X 18' H GAL V,
<br />FLASHING CONT,
<br />
<br />
<br />~
<br />z
<br />I
<br />V?
<br /><[
<br />-I
<br />u...
<br />
<br />f-
<br />Q::
<br />W
<br />>
<br />
<br />Co
<br />-
<br />
<br />SEALANT
<br />
<br />ELASHING
<br />~
<br />
<br />DDFING FELT
<br />
<br />NOTE: THIS DETAIL IS REQUIRED
<br />AT ALL VERTICAL 'WALL INTERSECTIONS
<br />'WITH ROOF V ALLEYS 8x ROOF CRICKETS,
<br />
<br />6' HORIZ,
<br />FLASHING
<br />
<br />FIGURE 2: WAll FINISH
<br />
<br />ELASHING I2ETAll AT CRICKET/KNEEWALL INT~ECTION
<br />FILEREF: (SD4)KNGSTN,FLSHDET ISD (NO SCALE)
<br />
<br />TEXTURED! PAINTED
<br />EXTERIOR 'WALL FINISH
<br />
<br /> 6' HIGH
<br /> DIVERTER
<br />a.. FLASHING
<br />::r::
<br />>.
<br />.0
<br />~
<br />co
<br />cD
<br />~
<br />0
<br />-
<br />~
<br />-<
<br />....
<br />0
<br />-
<br />~
<br />....
<br />~
<br />.
<br />co
<br />a)
<br />c>
<br />>
<br />cD
<br />'0
<br />N
<br />~
<br />~
<br />,
<br />a..
<br />::r::
<br />'0
<br />....
<br /><IS
<br />~
<br />c>
<br />d
<br />Q..
<br />I
<br />-
<br />-
<br />cD
<br />:.
<br />cD
<br />::c
<br /><lit
<br /><SO
<br />,g
<br />-
<br />cD
<br />..,
<br />c
<br />a
<br />co
<br />cD
<br />0
<br />a..
<br />:c
<br />
<br />
<br />
<br />HOLD EXTERIOR
<br />FINISH 28 ABOVE
<br />ROOF
<br />FLASHING
<br />
<br />
<br />PROPER INSTALLATION
<br />
<br />MAX. 8"
<br />
<br />o
<br />
<br />
<br />
<br />#5 REBAR (TYP.)
<br />
<br />o
<br />
<br />
<br />
<br />
<br />sm. 90' HOOK (TYP.)
<br />
<br />SEAL NT LI
<br />
<br />-NAIL SHINGLES ~ I 11 DR 12 GAUGE ROOFING
<br />NAILS, 3/8' MIN HEADS, 6 PER SHINGLE.
<br />
<br />NOTCH 'M::B AT THE FIRST 2 COURSES
<br />
<br />f5
<br />
<br />o
<br />
<br />FILLED CELL PER FOUNDA TlON PLAN
<br />
<br />o
<br />
<br />~~
<br />~~
<br />~~
<br />~~
<br />~~
<br />~~
<br />
<br />>-
<br />0::::
<br />Z
<br />o
<br />c.n
<br /><[
<br />:::::E
<br />u..
<br />o
<br />
<br />
<br />EXI5TING U-6LOCK WI I tS CONT.
<br />
<br />
<br /><,:>'0\(\9}~S
<br />() \'0e o.'y...e e;'(\ l\3
<br />t.,'j..\e(\\'0e f \ \/'(.: \S
<br />O\jef S o.'O?~ eej.r:;;;e3/ b,1
<br />eo.\j\~ ej.f~'oOI..l\ f\?
<br />f-f-I 'ej. of, ~ (\0 0:
<br />l..I%,e f-~I' ~<,:>eej.,
<br />~\'J.r:;;;e \S
<br />
<br />SHINGLE DETAil
<br />
<br />
<br />, ,
<br />,,"
<br />,,"
<br />,
<br />
<br />
<br />UNACCEPTABLE IN5T ALL TION ,,"
<br />DO NOT DO T~15 , ,
<br />,
<br />#5 REBAR (TYP.),,"
<br />,,"
<br />,,"
<br />,
<br />"fm. 90' HOOK (TYP.)
<br />4'
<br />
<br />
<br />6 TO 12'
<br />PER PLAN
<br />SPEC'S,
<br />
<br />Cut 2' (SO ,~?)
<br />r~!l\l'f oVM~er
<br />
<br />NOTE: IF RETROFIT FILLED CELL OR UPLIFT 5TRAP CONDITIONe
<br />EXCEED (,3) PER PROJECT, CONTACT EN~INEER OF RECORD
<br />FOR ADDITIONAL I N5TRUCT I ON.
<br />
<br />OOFING FEL T
<br />
<br />w
<br />U
<br /><[
<br />u..
<br />f-
<br />:::)
<br />u
<br />3:
<br /><[ .
<br />c.n
<br />
<br />DRILL 'lI'XS' MIN. OOLE
<br />5ET 6AR IN EPOXY
<br />CAP TO A<EYENT LEAKME
<br />
<br />~X~'EM6EDDED INTO
<br />EXISTING U-6LOCK LINTEL
<br />
<br />FILL CELL RILL l-IEl~l-iT WI
<br />NON-5l-iRINK GROUT
<br />
<br />
<br />
<br />~X6'EM6EDDED 'NTO
<br />EXISTING FOOTING
<br />
<br />N.T.S.
<br />
<br />DRIP EDGE
<br />
<br />SECTION
<br />5CALE, NT5
<br />
<br />CD
<br />
<br />FIllED CEll INSTAllATION
<br />5CALE: N.T.~.
<br />
<br />
<br />4"t 5AUJCUT
<br />
<br />PRODUC T CONTROL NOTICE OF ACCEPTANCE
<br />MIAMI - DADE COUNTY, FLORIDA
<br />
<br />MAUFACTURER - G S ROOFING PRODUCTS COMPANY, INC.
<br />
<br />D 5AMUEL A. GREENBERG, PE. "3424S
<br />D T~UY ~. ~U'YN~, P E. ~0122
<br />D IRWIN J. BEN50N, PE. .4~1S8
<br />D All ABBA5 ~AKIM, P E. ~b 18b
<br />
<br />& REVlSED 08-15-03
<br />ffi CREATED 02-27-02
<br />120 MPH
<br />3 SEe, GUST
<br />
<br />D E DANSCO
<br />
<br />ENGINEERING, FA"
<br />
<br />P.o.60X 3400 - APOLLO 6E~ - flORIDA - 33512
<br />~ - (813) 645 0166 FAX - (813) 645 <36~
<br />Et::Il. .A atA\ f(\ TIj[SE DRA'MNGS AND DESIGNS ARE TIjE JOINT PROPERTY Of DANSCO ENGINEERING, PA, AND TIjE
<br />"" ~ IV \(::)CUENT ON TIjIS PROJECT ANY REPRODUC1l0N OR UNAUTIjORIZED USE IS PROHIBITED, - 2003
<br />
<br />EXISTING FOOTIN~
<br />
<br />
<br />UPLIFT CAPACITY . S~ FOR I 5TRAP PRODUC T ACCEPTANCE # EXPIRATION DATE:
<br />. I~S~ FOR 2 5TRAP5
<br /> FiREHAL T 2000 01-0503.03 06 I 14 I 2006
<br />1-PL"" PRE-ENGINEERED iRU05 FlREHALT 2000 AR 01-0503.03 06 I 14 I 2006
<br /> LANDMARK 30 01-0503.03 06 I 14 I 2006
<br />'" 51MP5ON l-NS 5TRAP LANDMARK 30 AR 01-0503.03 06 I 14 I 2006
<br /> LANDMARK 40 01-0503.03 06 I 14 I 2006
<br /> (4) 50S 11I'xlV2' 01-0503.03 06 I 14 I 2006
<br /> LANDMARK 40 AR
<br />
<br />TO Tt4E 6EST OF Tt4E ENGINEER'S KNOWLEDGE AND 6ELlEF, Tt4E
<br />STRUCTURAL FLANS AND SFECIFICATIONS COMFL'r' WITt4 Tt4E
<br />FLORIDA 6UILDING CODE, SECTION 1~0~ FOR 12el MFt4 3 SECOND
<br />GUST, EXFOOURE '6' WIND ZONE (2001 EDITION),
<br />Tt4IS DRAWING AND DESIGN IS vALID FOR 12 MONTt4S AFTER Tt4E
<br />DATE IT IS SIGNED AND SEALED.
<br />SIGNED AND SEALED FOR Tt4E STRUCTURAL FORTION OF Tt4IS
<br />DRAWING ONL'r'.
<br />
<br />
<br />LENNAR ~OMEe
<br />
<br />DRILL. 'lI'X&' MIN. ~LE
<br />&ET 6AR IN EPOXY
<br />
<br />FfGU
<br />
<br />3: CO
<br />
<br />
<br />FLASHING INSTAllATION
<br />
<br />
<br />, '.
<br />I":-~~ ~::,
<br />
<br />eCALE NOTeD
<br />DATE 2121/02
<br />
<br />TAMPA Dlvl810N
<br />
<br />DRAU.N BV.
<br />N:/BlOCKS/STD 2001
<br />
<br />N.T.S.
<br />
<br />RETROFIT FILLED CELL DETAIL
<br />N. T .s.
<br />
<br />FRAMING CONNECTIONe 6 EXT" WALLe
<br />
<br />DE JOB NO. PM - S021
<br />
<br />83.1
<br />
|