My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-7285
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-7285
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:32:01 PM
Creation date
8/8/2008 7:12:10 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-7285
Building Department - Name
DAVIDSON,ALAN
Address
5117 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />Fire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />December 7,2007 <br /> <br />Plan Review Comments <br /> <br />I have reviewed and approved the plan for an interior remodel located at 5117 Gall Blvd <br />under the following conditions. My comments have been placed below. Please contact <br />me if you have any questions with regards to my comments. <br /> <br />1. Firewall shall be screwed accordingly. Interior layer I" type "s" screw 12" OC in <br />field and 8" OC along all edges/joint. Second layer 1 5/8" type "S" screw <br />patterned the same way as the first layer. Firewall shall be fire caulked at roof <br />deck and down ends of wall. Firewall shall be labeled "FIREWALL DO NOT <br />PENETRATE". <br />2. Panic hardware required on rear exit. <br />3. Fire rated door shall have a fire rating of 1 hr 45 minutes. Certification plate shall <br />be on door for identification. <br />4. Smoke detectors shall be installed in all storage related areas, hardwired with <br />battery backup and tied together. <br />5. Exit signs in retail area shall be battery backup with emergency lighting. If not <br />separate emergency light shall be installed in the retail area <br />6. Set up retail area to have adequate aisle space to accommodate wheel chair <br />access. <br />7. Certified fire extinguisher required in retail area and shop area <br /> <br />Inspections required: (call inspections into building department) <br /> <br />1. Firewall inspection. Each layer shall have a screw inspect and 1 overall final. <br />2. Building final. <br />
The URL can be used to link to this page
Your browser does not support the video tag.