Laserfiche WebLink
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />Fire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />December 7,2007 <br /> <br />Plan Review Comments <br /> <br />I have reviewed and approved the plan for an interior remodel located at 5117 Gall Blvd <br />under the following conditions. My comments have been placed below. Please contact <br />me if you have any questions with regards to my comments. <br /> <br />1. Firewall shall be screwed accordingly. Interior layer I" type "s" screw 12" OC in <br />field and 8" OC along all edges/joint. Second layer 1 5/8" type "S" screw <br />patterned the same way as the first layer. Firewall shall be fire caulked at roof <br />deck and down ends of wall. Firewall shall be labeled "FIREWALL DO NOT <br />PENETRATE". <br />2. Panic hardware required on rear exit. <br />3. Fire rated door shall have a fire rating of 1 hr 45 minutes. Certification plate shall <br />be on door for identification. <br />4. Smoke detectors shall be installed in all storage related areas, hardwired with <br />battery backup and tied together. <br />5. Exit signs in retail area shall be battery backup with emergency lighting. If not <br />separate emergency light shall be installed in the retail area <br />6. Set up retail area to have adequate aisle space to accommodate wheel chair <br />access. <br />7. Certified fire extinguisher required in retail area and shop area <br /> <br />Inspections required: (call inspections into building department) <br /> <br />1. Firewall inspection. Each layer shall have a screw inspect and 1 overall final. <br />2. Building final. <br />