<br />EnergYGauge~ 4.5.2
<br />
<br />SIMPSON MECHANICAL
<br />
<br />Code Compliance Checklist,
<br />Residential Whole Building Performance Method A - Details
<br />
<br />[ ADDRESS: t t t
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />. . .
<br />CONlPONEN.T~ _ SECTIQ.N_. .~VlREMEN.T.S FOR.~CH ~~CTICE . __., '__"__
<br />E~erjor Wind~l..l?oo" 606.1.:..ABC.1,1 _ Ma)(i!T1um:.3 ~~/sQ.fI. wi!!dow .rea; .5 cf[n/SQ.ft. doo~ are.. ',__,__ ,_
<br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 C.ulk, gasket, weatherstrip or seal between: windows/doOl'$ & frames, surrounding wall;
<br />foundation & wall sole or sill Plate; joints between exterior WBII panels at comers; utility
<br />penetrations; between wall panels & toplbottom plates; between walls and floor.
<br />EXCEPTION: Frame wells where 8 continuous infiltration barrler is inltalleclthat extends
<br />fro.fl\,. and Is se!lled to, lhe fOul'!~~~on to ttle ~~!~!!L-- , ._ '_"._
<br />806.1,ABC.1.2.2 Pen.tretionl/openings >1/8" sealed unless backed by IruSl or JoInt membel'$.
<br />EXCEPTION: Frame floors where a conllnuous infiltration barrier is Installeel that 1$ sealed
<br />to t~~ p.rin)e\~r, penetrations an~ seams. __ _ .... _.__._ .
<br />606.1.ABC.1,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts. chales,
<br />soffits, chimne)'5, cabinets sealed to conUnl.lOUs air barrier; gapa in l1YP board & top plate;
<br />atuc access. EXCEPTION: Frame ceilln9s where a continuoue infiltratIon barrier is
<br />.. ,- -- --. i~Slalled tha,t is S'~Ie~ at the l)~rim8ter, ~t penetrations and !5~ams. _ . ____ ,
<br />Rect$$ed Lighting Fixturee 60e.1.ABC.1.2.4 Type IC rated with no penelrations, sealed; or Type IC or non.IC rlted. in$talled inside e
<br />sealed box with 112" Clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
<br />_ QOndillonet/space.teSIed. .._ __, "__,..__
<br />Multi-4i~rY- Hou~s __ '. 606.1.ABC.1.2,.5 Air ~~rrier on o.e~meter of noor caVitY. between floors. . u_, .~ __ ._, " ~.
<br />AClditionallnfiftration reqts 606,1,ABC.1.3 Exhaust fans vented to outCloors, dampers: combuslion space heaters comply with NFPA.
<br />have combustiOn air. I
<br />
<br />PERMIT #:
<br />
<br />J.
<br />
<br />~HEC
<br />
<br />Floors
<br />
<br />Ceilings
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
<br />
<br />COMPO~~NTS., _'.
<br />Water Heaters
<br />
<br />SECTI91L-
<br />612.1
<br />
<br />REQ_U!~N~. _.. __ "___. CHECK
<br />Comply with efficiency requlrementl in Table 612.1 ABC.3.2. Switch or clearly marked cir
<br />breaker. (electric) cn cutoff (gas) mus! be.provld~~. External or:.!!!!!!1:la.beat trap rllQu.i'1ld. ..
<br />Spas & healed pOOls must have Covers (except solar heated). Non-commerciar pools
<br />must have II pump timer, Gas spa & pool heaters must have a minimum thermal
<br />efficlency of 78%. _ _, .. ____ __.__,
<br />yiate,:f1.ow must.be. restricted.to no more than 2\~.gallone qer minute .tJ~g PSIG.. .
<br />All ducts. fIltings, mechlllnical equipmenl and plenum chambers shall be mechanically
<br />attached, sealed, insulated, and installed in accordanee with the criteria Of Section 610.
<br />.Ducts In ~n_condit.i.oned atti~; R.6 min.. il)~, _,. '__ ____
<br />Se ,arate rell~!!Y. acceSSi!!le manu~1 or autof!latic then:nostat fo~ach sYStem... ____
<br />CeilingS-Min. R-19. Common wafls-Frame R-11 or CBS R-3 both sleles,
<br />Common ceiling & floors R-11.
<br />
<br />-- .--" -
<br />
<br />Swimming Pools & Spas
<br />
<br />612.1
<br />
<br />Shower heads _.
<br />AIr Oi,llribution Systems
<br />
<br />~12.1
<br />610.1
<br />
<br />-"_0...__ _
<br />
<br />HVAC ~!>ntrols.
<br />Insulation
<br />
<br />607,1 .___
<br />604.1. 602.1
<br />
<br />EnergyGaugelM DCA Form eOOA.2004R
<br />
<br />Energ~8ug~laRES'2004R FLRCSB v4.S.2
<br />
|