08-7665
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7665
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:46:27 PM
Creation date
8/14/2008 9:46:30 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7665
Building Department - Name
FLORIDA MEDICAL
Address
38107 MARKET SQ DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />(b Smoke Detector Specifications <br /> <br /> <br />Smoke detector shall be a System Sensor i3 Series model number~ listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The <br />detector shall be a photoelectric type (ModeI2W..f3. 4W-B) or a combination photoelectric/thermal (Model 2WT-B,4WT-B) with thermal sensor rated at 13S'F <br />(S7.2'C). The detector shall include a mounting base for mounting to 3'h-inch and 4-inch octagonal, single gang. and 4-inch square back boxes with a plaster <br />ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means ofSEMS screws. The detector shall allow pre-wiring of <br />the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 25 percent-per-foot nominal as measured in the UL smoke box. <br />The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide <br />dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When <br />used in conjunction with the 2W-M0D2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control <br />panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. <br /> <br />Operating Voltage <br /> <br /> <br /> <br />Maximum Ripple Voltage <br />Standby Current <br />Maximum Alarm Current <br />Peak Standby Current <br />Alarm Contact Ratings <br /> <br />Dimensions (including base) <br />Weight <br />Operating Temperature Range <br />Operating Humidity Range <br />Thermal Sensor <br />Freeze Trouble <br />Sensitivity <br />Input Terminals <br />Mounting <br /> <br />Nominal: 12J24V non-polarized <br />Minimum: 8.5V <br />Maximum: 3SV <br />30% peak to peak of applied voltage <br />2-wire: SO I1A maximum average; 4-wire: 50 I1A maximum average <br />2-wire: 130 mA limited by control panel; 4-wire: 20 mA@12V, 23mA@ 24V <br />2-wire: 100 I1A; 4-wire: nla <br />2-wire: n/a; 4-wire: 05 A @ 30V ACJOC <br /> <br />S3 inches (127 mm) diameter; 2.0 inches (S 1 mm) height <br /> <br />63 oz. (178 grams) <br />2W-B and 4W-B: 32'F-120oF (0'(-4900; 2WT-B and 4WT-B: 32"F-1 oooF (0'(-37.8'() <br /> <br />o to 95% RH non-condensing <br />13soF (S7.200 fixed <br /> <br />2WT..f3 and 4WT-B only:41'F (S'O <br />2.5%/ft. nominal <br />14-22 AWG <br /> <br />3'h-inch octagonal back box <br />4-inch octagonal back box <br />Single gang back box <br />4-inch square back box with a plaster ring <br />Direct mount to ceiling <br /> <br />LED Modes Power Up Sequence for LED Indication <br /> <br />LED Mode <br />Power up <br />Normal (standby) <br />Out of sensitivity <br />Freeze trouble <br />Alarm <br /> <br />Green LED <br />Blink every 10 seconds <br />Blink every 5 seconds <br />off <br />off <br />off <br /> <br />Ordering Information <br /> <br />Condition <br />Initial LED status indication <br /> <br />Duration <br />80 seconds <br /> <br />Red LED <br />Blink every 10 seconds <br />off <br />Blink every S seconds <br />Blink every 10 seconds <br />Solid <br /> <br /> <br />No 2-wire <br />Yes 2-wire <br />No 4-wire <br />Yes 4-wire <br /> <br />130 mA max limited by control panel <br />1 30 mA max limited by control panel <br />20 mA @ 12V, 23mA @ 24V <br />20 mA @ 12V, 23mA @ 24V <br /> <br />2W-B <br />2WT-B <br />4W-B <br />4WT-B <br />Accessories <br />2W-M0D2 <br />SENS-RDR <br /> <br />RT <br />A77-AB2 <br /> <br />Removal/replacement tool <br />Retrofit adapter bracket, 6.6 in. (16]6cm) diameter <br /> <br />2-wire loop test I maintenance module <br />Sensitivity reader <br /> <br />~ SYSTEM <br />C~ SENSOR' <br /> <br />382S Ohio Avenue. St Charles, IL 60174 <br />Phone: 800-SENSOR2. Fax: 630-377-6495 <br /> <br />4:)2006 Sysrem Sensor <br />Product specifications subjeCt to change without no1jce. Visit syslemsensor.com for <br />(urtt'nt prodllCT jnform~tion. including the lalest ver'iioo of rhi~ ci.lra ~hf't'1 <br />AOS...{)318-006. 7/06. , 1676 <br />