Laserfiche WebLink
<br />Nationwide Insurance,- Center for Radiation Oncology, 7315 Green Slope Drive, Zephyrhills, FL <br />Lab No.. 190442 Page 15 <br /> <br />under the direction and supervision of both a Professional Engineer licensed in the <br />State of Florida whose field of expertise is geotechnical engineering and a <br />Professional Geologist licensed in the State of Florida who has geological <br />experience and expertise in the identification of sinkhole activity. Both the <br />engineer's and geologist's signatures and seals with Florida Registration Numbers <br />appear on the report. <br /> <br />We certifY that it is our professional opinion, based on the data generated by this <br />investigation, that there is evidence of sinkhole activity occurring under the <br />property and that it cannot be eliminated as a possible cause of damage. The <br />analysis conducted, in our opinion, was of sufficient scope to identifY sinkhole <br />activity as a possible cause of the damage described within a reasonable <br />professional probability. <br /> <br />Limitations <br /> <br />The geotechnical investigation and report deals only with the soil zones and strata <br />located within the area represented from the ground surface to the termination <br />depth of the boring. <br /> <br />It is not intended to predict or accept responsibility for sinkhole development, but <br />rather, to define the soil profile consistent with determining if sinkhole related <br />activity is present under the property. This determination of activity cannot <br />construct a time frame to past action or predict a time period to future activity. <br /> <br />Generally accepted soil mechanics and foundation engineering practices were <br />utilized in the preparation of this report; and no other warranty, either expressed <br />or implied is made as to the recommendations provided. <br /> <br />This report is for the exclusive use of our client and may not contain sufficient <br />information for other uses, such as quantity take-offs, or for interpretation by <br />other parties for bidding purposes. In the event others make conclusions and/or <br />recommendations based on our data, such conclusions and/or recommendations <br />are not our responsibility unless we have been given an opportunity to review and <br />concur with them. <br />If borings were not staked by a registered land surveyor but were located by our <br />drill crews, the following method was used: <br /> <br />Distances are generally measured using a 200 foot tape measure with right angle <br />approximation used to turn comers. Scaling from prints or surveys with reference <br />points shown on the plan or geographical references will produce a degree of <br />accuracy that is typically + 5% for length and + 10 degrees for angles. <br /> <br />Soil strata delineations are estimated in the field by color changes, texture <br />differences and penetration resistance values. These may be more gradual <br />transitions than those shown on the boring log representations of strata <br />delineations. <br /> <br />The ground water depth determination shown on the left side of the boring log <br />was measured in the borehole at the time of drilling, unless noted otherwise. This <br />depth does not reflect seasonal high water levels and would fluctuate as expected <br />with variations in rainfall or other factors not present at the time of our soils <br />investigation. <br /> <br />Central Florida Testing Laboratories, Inc. <br />12625 - 40th Street North, Clearwater, FL 33762 <br />