Laserfiche WebLink
<br />Wind Soeed: <br />Exoosure: <br />Sian Heiaht: <br />Imoortance Factor: <br />Wind Pressure: <br /> <br />120 MPH <br />B <br />30 ft <br />0.77 <br />21.46 psf <br /> <br /> <br />Company: <br />Proiect: <br />Location: <br /> <br />Florida Sign Com pany <br />Wal-Mart <br />Zephyrhills, FL <br /> <br />'I"'" <br /> <br />~....*' <br /> <br />. <br /> <br />1875 WEST MAIN ST. <br />BARTO~ FLORIDA 33830 <br />FL C.OA No. 00008883 <br /> <br /> <br />~ 111...__ <br /> <br /> <br />Width of Sian = <br /> <br />ft <br /> <br />12 in <br /> <br />Allowable Shear Value = <br /> <br />110 Ibs/Anchor <br /> <br />Heiaht of Sian = <br /> <br />ft <br /> <br />12 in <br /> <br />Allowable Tension Value = <br /> <br />109 Ibs/Anchor <br /> <br />Area = <br /> <br />1 .00 fe <br /> <br />Number of Anchors = <br /> <br />2 <br /> <br />Shear oer Bolt = ( Area x 10 psf ) 1 # Bolts = <br /> <br />5.00 Ibs <br /> <br />Tension oer Bolt = (Area x Wind Pressure) 1 # Bolts = <br /> <br />10.731bs <br /> <br />Bolt Value = ( Shear per Bolt 1 Shear Value) + ( Tension per Bolt 1 Tension Value) <br /> <br />Bolt Check <br /> <br />~Bolt Value - 0.14 < <br /> <br />1.33~ <br /> <br />$/ <br /> <br />l/- z2-al <br /> <br />Use a minimum of (2) of the following anchor options per letter: <br />- 1/4" dia. x 11/2" emb. Lag screws into 1/2" plywood or wood studs. <br />- 1/4" dia. x 1 1/2" Tapcons into CMU or Concrete. <br />- 1/4" dia. Thru Bolts into 2x4 cont. wood runner behind wall studs. <br /> <br />All loads per Florida Building Code 2004 with 2007 revisions and ASCE 7-02 <br /> <br />4/22/2008 <br />Alan C. Plants, P.E. <br />FL P.E. No. 63913 <br />