Laserfiche WebLink
<br />Wind Soeed: <br />Exoosure: <br />Sian Heiaht: <br />Imoortance Factor: <br />Wind Pressure: <br /> <br />120 MPH <br />B <br />30 ft <br />0.77 <br />21.46 sf <br /> <br /> <br />Company: <br />Proiect: <br />Location: <br /> <br />Florida Sign Company <br />Wal-Mart <br />Zephyrhills. FL <br /> <br />....... <br /> <br />~~~ <br /> <br />1875 WEST MAIN ST. <br />BARTOI>Y, FLORIDA 33830 <br />FL C.O.A. No. 00008883 <br /> <br /> <br /> <br />~ <br /> <br />~~fT AE...~~ ~t~ <br /> <br /> <br />Width of Sian = <br /> <br />2ft <br /> <br />6 in <br /> <br />Allowable Shear Value = <br /> <br />110 Ibs/Anchor <br /> <br />Heiaht of Sian = <br /> <br />2ft <br /> <br />6 in <br /> <br />Allowable Tension Value = <br /> <br />109 Ibs/Anchor <br /> <br />Area = <br /> <br />6.25 ft2 <br /> <br />Number of Anchors = <br /> <br />4 <br /> <br />Shear oer Bolt = ( Area x 10 psf ) 1 # Bolts = <br /> <br />15.63 Ibs <br /> <br />Tension oer Bolt = ( Area x Wind Pressure) 1 # Bolts = <br /> <br />33.53 Ibs <br /> <br />Bolt Value = ( Shear per Bolt 1 Shear Value) + ( Tension per Bolt 1 Tension Value) <br /> <br />Bolt Check <br /> <br />~Bolt Value = 0.45 < <br /> <br />1.33 [2[] <br /> <br />Use a minimum of (4) of the following anchor options per letter: <br />- 114" dia. x 1 112" emb. Lag screws into 112" plywood or wood studs. <br />- 114" dia. x 1112" Tapcons into CMU or Concrete. <br />- 114" dia. Thru Bolts into 2x4 cant. wood runner behind wall studs. <br /> <br />d~ <br /> <br />All loads per Florida Building Code 2004 with 2007 revisions and ASCE 7-02 <br /> <br />4/22/2008 <br />Alan C. Plants, P.E. <br />FL P.E. No. 63913 <br />