My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7840
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7840
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:45:33 PM
Creation date
8/21/2008 9:22:55 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7840
Building Department - Name
RYMAN CONSTRUCTION
Address
6834 MEDICAL VIEW LN LT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />Fire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />May 9, 2008 <br /> <br />Plan Review Comments <br /> <br />I have reviewed and approved the plans for an interior build-out located at 6834 Medical <br />View Ln. under the following conditions. My comments have been placed below. <br />Please contact me if you have any questions with regards to my comments. <br /> <br />1. Certified fire extinguishers shall be installed in compliance with NFP A 10. <br />2. Knox box required per Florida Fire Prevention Code. Obtain application from <br />Zephyrhills Fire Rescue, <br />3. Install emergency lights in handicap bathrooms. <br />4. Remove smokes for fire alarm system in bathrooms and staff area. Also remove 2 <br />smokes from main treatment room, <br />5. Install smokes in storage and break room. Relocate remaining smokes in main <br />treatment room to the center of that room. <br />6, Install heat detector in laundry room. <br />7. Fire Alarm system shall be installed in accordance with NFP A 72, 2007 edition. <br />Fire alarm contractor shall submit plans (including battery cales, details, cut <br />sheets, etc.) for review and permit. There shall be strobes only in bathrooms, <br />Install horn/strobe in hall by storage room. <br />8. Duct detectors shall be installed and tied to fire alarm system. Units shall have <br />ducts and shall not be an open plenum. If installed as an open plenum- bi fold <br />doors can not be used and a regular door shall be installed. Fire dampers shall be <br />installed for the air intake, Also no storage will be allowed in this room, <br /> <br />Inspections required: <br /> <br />1. Firewall (screw and final) <br />2. Building final. <br />3. Additional inspections are required through other contractors performing work <br />and will be listed on their plan review comment sheets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.