My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7877
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7877
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:45:20 PM
Creation date
8/21/2008 9:49:40 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7877
Building Department - Name
NUCCIO,MESHELLE
Address
6153 17TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />be ladders, stairs or underwater benches/swimouts in the deep <br />end. Where manufactured diving equipment is to be used, <br />benches or swimouts shall be recessed or located in a comer. <br /> <br />Exception: In private pools having more than one shallow <br />end, only one set of steps are required. A bench, swim-out or <br />ladder may be used at all additional shallow ends in lieu of <br />an additional set of steps. <br /> <br />R4101.19 Final inspection. All swimming pool installations <br />must be completed. The pool shall be completely filled with <br />water and in operation before final inspection. <br /> <br />R4101.20 Filters. The entire design of matched components <br />shall have sufficient capacity to provide a complete turnover of <br />pool water in 12 hours or less. <br /> <br />R4101.20.1 Sand filters. <br /> <br />R4101.20.1.1 Approved types. Rapid sand filters (flow <br />up to 5 gpm per square foot) shall be constructed in ac- <br />cordance with approved standards. Where high rate sand <br />filters (flow in excess of 5 gpm per square foot) are used, <br />they shall be of an approved type. The circulation system <br />and backwash piping shall be adequate for proper back- <br />washing of said filter and shall provide backwash flow <br />rates of at least 12 gpm per square foot or rapid sand fil- <br />ters or 15 gpm per square foot or high rate sand filters. <br /> <br />R4101.20.1.2 Instructions. Every filter system shall be <br />provided with written operating instructions. <br /> <br />R4101.20.1.3 Filter system equipment. On pressure <br />type filters, a means shall be provided to permit the re- <br />lease of internal pressure. A filter incorporating an auto- <br />matic internal air release as its principal means of air <br />release shall have lids which provide a slow and safe re- <br />lease of pressure as part of its design. A separation tank <br />used in conjunction with a filter tank shall have as part of <br />its design a manual means of air release or a lid which <br />provides a slow and safe release of pressure as it is <br />opened. <br /> <br />R4101.20.2 Diatomite type filters. <br /> <br />R4101.20.2.1 Design. Diatomite-type filters shall be de- <br />signed for operation under either pressure or vacuum. <br />The design capacity for both pressure and vacuum filters <br />shall not exceed 2 gpm per square foot of effective filter <br />area, <br /> <br />R4101.20.2.2 Filter aid. Provision shall be made to in- <br />troduce filter aid into the filter in such a way as to evenly <br />precoat the filter septum. <br /> <br />R4101.21 Pool fittings. <br /> <br />R4101.21.1 Approved type. Pool fittings shall be of an ap- <br />proved type and design as to be appropriate for the specific <br />application. <br /> <br />R4101.21.2 Skimmers. Approved surface skimmers are re- <br />quired and shall be installed in strict accordance with the <br />manufacturer's installation instructions. Skimmers shall be <br />installed on the basis of one per 800 square feet (74 m2) of <br />surface area or fraction thereof, and shall be designed for a <br />flow rate of at least 25 gallons per minute (gpm) (1.6 Us) per <br />skimmer. <br /> <br />FLORIDA BUILDING CODE - RESIDENTIAL <br /> <br />SWIMMING POOLS <br /> <br />R4101.21.3 Main outlet. An approved main outlet, when <br />provided, shall be located on a wall or floor at or near the <br />deepest point in the pool for emptying or circulation, or <br />both, of the water in the pool. <br /> <br />R4101.21.4 Hydrostatic relief device. In areas of antici- <br />pated water table an approved hydrostatic relief device shall <br />be installed. <br /> <br />Exception: Plastic liner pools (where there is no struc- <br />tural bottom to the pool). <br /> <br />R4101.21.5 Inlet fittings. Approved manufactured inlet fit- <br />tings for the return of recirculated pool water shall be pro- <br />vided on the basis of at least one per 300 square feet (28 m2) <br />of surface area. Such inlet fittings shall be designed and con- <br />structed to insure an adequate seal to the pool structure and <br />shall incorporate a convenient means of sealing for pressure <br />testing of the pool circulation piping. Where more than one <br />inlet is required, the shortest distance between any two re- <br />quired inlets shall be at least 10 feet (3048 mm), <br /> <br />R4101.22 Equipment foundations and enclosures. All pool <br />motors and equipment shall be installed in compliance with the <br />manufacturers recommendations. All heating and electrical <br />equipment, unless approved for outdoor installation, shall be <br />adequately protected against the weather or installed within a <br />building, <br /> <br />R4101.23 Accessibility and clearances. Equipment shall be <br />so installed as to provide ready accessibility for cleaning, oper- <br />ating, maintenance and servicing. <br /> <br />SECTIONS E4102 through E4109 <br />Reserved. <br /> <br />41.7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.