<br />PRODUCT LINE INFORMATION <br /> <br />AUTOPULSE 542R: Six zone, 24 volt Agent Release Control Panel <br />(includes backpox, power supply, technical manual, and a frame & post <br />operating instruction sheet) for single and dual hazard deluge and <br />preaction applications. <br /> <br />AUTOPULSE 542R(E): Same as above but allows connection to <br />220/240 VAC. <br /> <br />CAC-5X: Class A Converter Module can be used to convert the Style B <br />(Class B) Initiating Device Circuits to Style 0 (Class A) and Style Y <br />(Class B) Output Circuits to Style Z (Class A). <br /> <br />Note: Two Class A Converter modules are required to convert all four <br />Output Circuits and six Initiating Device Circuits. <br /> <br />4XTM: Transmitter Module provides a supervised output for local energy <br />municipal box transmitter and alarm and trouble reverse polarity. It <br />includes a disable switch and disable trouble LED. <br /> <br />N-ANN-80: LCD Annunciator is a remote LCD annunciator that mimics <br />the information displayed on the FACP LCD display. Recommended wire <br />type is un-shielded. <br /> <br />N-ANN-LED: Annunciator Module mounts in the DP-51050LED Dress <br />Panel and provides three LEOs for each zone: Alarm, Trouble and <br />Supervisory. <br /> <br />N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, <br />provides 10 programmable Form-C relays. <br /> <br />N-ANN-SIPG: SeriallParallel Printer Gateway module provides a <br />connection for a serial or parallel printer. <br /> <br />N-ANN-I/O: LED Driver Module provides connections to a user-supplied <br />graphic annunciator. <br /> <br />DP-51050: Dress panel (red) is available as an option. The dress panel <br />restricts access to the system wiring while allowing access to the <br />membrane switch panel. <br /> <br />DP-51050LED: Dress panel is available as an option. The dress panel <br />restricts access to the system wiring while allowing access to the <br />membrane switch panel. It also allows the installation of an optional <br />ANN-LED annunciator module. <br /> <br />TR-CE: Trim-ring (red) is available as an option. The trim-ring allows <br />semi-flushing mounting of the cabinet. <br /> <br />BB-26: Battery box, holds up to two 26 Amp Hour batteries and <br />CHG-75. <br /> <br />BB-55: Battery box, houses two 55 Amp Hour batteries. <br />BAT Series Batteries <br /> <br />F <br /> <br />SYSTEM SPEClFlCAnONS <br /> <br />SYSTEM CAPACITY <br />. Annunciators: 8 <br /> <br />ELECTRICAL SPECIFICATIONS <br />. AUTOPULSE 542R (FLPS-7 Power Supply): 120 VAG, 50/60 Hz, <br />2.3 amps <br />. AUTOPULSE 542R(E) (FLP5-7 Power Supply): 240 VAC, 50 HZ, <br />1.15 amps <br />. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insulation, super- <br />vised, nonpower-Iimited <br /> <br />CABINET SPECIFICATIONS <br />Door: 19.26 in. (48.92 cm) high x 16.82 in. (42.73 cm) wide x 0.72 in. <br />(1.82 cm) deep <br />Backbox: 19.00 in. (48.26 cm) high x 16.65 in. (42.29 cm) wide x <br />5.25 in. (13.34 cm) deep <br />Trim Ring (TR- CE):22.00 in. (55.88 cm) high x 19.65 in. (49.91 cm) <br />wide <br /> <br />SHIPPING DIMENSIONS <br /> <br />- Height: 20.00 in. (50.80 cm) <br /> <br />- Width: 22.50 in. (57.15 cm) <br /> <br />- Depth: 8.50 in. (21.59 cm) <br /> <br />TEMPERATURE AND HUMIDITY RANGES <br /> <br />This system meets NFPA requirements for operation at 32-120 OF <br />(049 OC) and at a relative humidity 93% :l: 2% RH (non-condensing) at <br />90 OF :l: 3 OF (32 oC :l: 2 OC). However, the useful life of the system's <br />standby batteries and the electronic components may be adversely <br />a ft:lcted by extreme temperature ranges and humidity. Therefore. it is <br />recommended that this system and its peripherals be installed in an <br />environment with a normal room temperature of 60-80 OF (15-27 OC). <br /> <br />NFPA STANDARDS <br /> <br />- NFPA 12 CO2 Extinguishing Systems (High Pressure Only) <br /> <br />- NFPA 12A Halon 1301 Extinguising Systems <br /> <br />- NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and <br />Remote Station Fire Alarm Systems (requires an optional Remote <br />Station Output Module) <br /> <br />- NFPA 2001 Clean Agent Fire Extinguishing Systems <br /> <br />USTINGS AND APPROVALS <br /> <br />The listings and approvals below apply to the basic AUTOPULSE 542R <br />and AUTOPULSE 542R(E) control panels. In some cases, certain <br />modules may not be listed by certain approval agencies, or listing may <br />be in process. Consult factory for latest listing status. <br /> <br />. UL: S4935 <br /> <br />ORDERING INFORMA11ON <br /> <br />Part No. <br /> <br />433605 <br />433606 <br /> <br />Description <br />AUTOPULSE 542R FACP, 120 VAC <br />AUTOPULSE 542RE FACP, 220/240 VAC <br />