<br />Detection and Control Components
<br />
<br />Alarm Bell - 6 or 10 Inch
<br />
<br />Features
<br />
<br />. High sound output with low current draw
<br />
<br />. Low frequency aluminum shells for better audibility through
<br />walls, doors, and other structures
<br />
<br />. Integral RFI suppression to minimize induced noise on the
<br />alarm circuit
<br />
<br />. Mounting options for surface, semi-flush, outdoor, and con-
<br />cealed conduit installation
<br />
<br />. Built-in trimplate makes semi-flush mounting simpler and
<br />less expensive
<br />
<br />. Screw terminals permit fast in-out field wiring of
<br />22-12 AWG wire
<br />
<br />. Polarized for DC supervision of alarm circuit
<br />
<br />, Operate on filtered or unfiltered DC
<br />
<br />Description
<br />
<br />ANSUL@ alarm bells may be used to alert the occupant
<br />before and/or during actuation of the Ansul automatic fire
<br />suppression system and/or a general fire alert.
<br />
<br />The ANSUL motor driven alarm bell is designed to meet the
<br />special requirements of fire alarm/release systems where
<br />low power consumption and high sound output is essential.
<br />Due to its low current drain, high level output sound can be
<br />achieved with multiple units on a single 2-wire output circuit.
<br />
<br />The bells are constructed of high quality materials to ensure
<br />reliability and long life. The basic mechanism, gong and
<br />accessories have a baked, red enamel finish. Holes are
<br />located to mount to a standard 4 in. (102 mm) square outlet
<br />box. A weatherproof back box is available for outdoor use.
<br />
<br />Technical Information
<br />
<br />Input Terminals: . . . . . . . . . . . . . . . . . . . . . . . . . 22 to 12 AWG
<br />
<br />Bell Sjzes:. .. . . . . . . . . . 6 in. (152 mm) and 10 in. (254 mm)
<br />
<br />Voltage Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 31 VDC
<br />
<br />Current Draw: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
<br />
<br />Decibel Level: . . . . . . . . . . . . . . .92 dBA @ 10 ft. (3048 mm)
<br />
<br />Operating Temperature:. . -31 OF to 150 OF (-35 oC to 66 oc)
<br />@ 95% humidity (when used with
<br />WBB, weatherproof back box)
<br />
<br />6 INCH BELL
<br />
<br />
<br />,J.e
<br />(70mm)
<br />+
<br />
<br />)
<br />
<br />003003
<br />
<br />10 INCH BELL
<br />
<br />10 IN.
<br />(254 mm)
<br />
<br />
<br />231tN. r---
<br />(70 mm) L--
<br />+
<br />
<br />-
<br />
<br />1
<br />
<br />l
<br />
<br />000004
<br />
<br />WIRING FOR BELL
<br />
<br />~~
<br />TO NEXT FROM
<br />g~VE~ ~ ~ ~~OL
<br />001365
<br />
<br />2-1-06