Laserfiche WebLink
<br />JAN-21-2008 12:33 <br />rUrt1V1 OUUJo\-olUU4K <br /> <br />SIMPSON MECHANICAL <br /> <br />813 SS8 8S78 P.08 <br />EnergyGauge@ 4.5.2 <br /> <br />Code Compliance Checkl'ist <br />Residential Whole Building Performance Method A - Details <br /> <br />fAOORESS:',. , <br />6A.-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br /> ... ....... - -'0.- .. <br />J!QM~.Q~I;;.~TS SECTION .. " I. .._ REQUIREMENTS F'OR ~_A~1:l P~.gTICE CHECK . <br />Extsrior Y.VJnlt9~ & Doors 606.1.A8C.1.1.. " . Maximum:.3 cfrn1sq.ft. wind,,:tY area; .5 q!!l/sg}l. door area. .---....,.,....... .- <br />Exterior & Adjacent Walls 606,1,ABC.1.2.1 Caulk, ga.sket, weat"srstrip or seal belween: w1ndows/dOQr$ & frames, surrounding wall; <br /> foundation & wall Sole or sill plate; joints between exterior wall'panela at corners; utility <br /> penetrations; between wall panels & toplbottom plates: between walls and floor. <br /> EXCEPTION: Frame w<llIs where a continuous infiltration barrier is installed that extends <br />--... . -.-.- .__u __ "', .,. __ from, and is sealed to, the J9u!,!d.ali~.!!!o the toe Dlate_ <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >118n sealed unless backed by h'U9S Or jointl11embers. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that Is sealed <br />-. --..-.- " .. .. ,.------- 19.__!b_~ .P~r,i~~~r.L2!!netrations and seams,_._. __ ___.__ . __........ " '.d _ M ............ ...__...___.____ ----' <br />Ceilings 606.1,ABC.1.2,J Between walls & ceilings; penetratiorui of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; , <br /> attic access. EXCEPTION: Frame ceilings where a continuous Infiltration barrier Is <br />- -.-.----.-----......--- .. . .-... Installed that i~_~"al!:ld. .a!_Jh~ perimeter, at penetrations and I!!@!n~,._ . .... . ... ... _h_.._ ----- <br />Recessed LighUng Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetration9, sealed; orType IC or non-IC rated, Installed inside a <br /> sealed box with 1/2" clearance & 3" from Insulation; Or Type Ie rated with < 2.0 crm from <br />1------- --... ....-. --... ,.. ,,~nditioned space. tested. ----.. , . ....----.-.-------- ----.--_., <br />Mulli--story Houses _ _~9~..1.ABC.1.2.5 Air balTler on ~.!ime~,:,.r. .of floor cavity between floora. ---.. ,.... ."" ,,,....,,..~- --,...._----- <br />Additional Infiltration rBqts 606.1.ABC .1.3 Exhaust fans vented to outdoors, dampers; combustion space he<lters comply witl'1 NFPA, <br /> have combustion air. I <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by illl residences.) <br /> <br />COMPONENTS .. ,. . .. SECTION REQUIB~~5!lTs --- .--...... ,.....~..........._. .,,--- ..------ CHECK' <br />Water Heaters 612.1 Comply with efficiency requlrementa in Table 612.1.ABC.3.2. Switch or clearly marked elr <br />.-.......~.... - ..---.. .~~aker (electric) or cutoff J9.~ ",u~t,be, pr~vided. Extern,1 or built-In heat traD l'8Oulred. <br />Swimming Pools & Spas 612.1 Spas 8. heated pOOls must have covers (except solar heated). Non.commercial POOlS <br /> must have a pump timer. Gas spa 8. poOl heaters must nave a minimum thermal <br />--.....- "."R .. . - --.. ..!f!!.~Elncy of 78%. ..---..--.. .......--. -- <br />Showerhe,ds .----. . .. 6121.______ _. \IY.a~~t!low must be restricted to no more t~~.('l_~,s,.9!llons per minute at 80 PSIG. --- --~.- <br />Nr Oistribution Systems 610.1 All ducls, fltllngs, mechanical equipment and plenum chllmbere shall be mechanically <br /> attached, sealed, Insulated, and installed in accordance with the crlteria of Section 610. I <br />.--.--. -- . , _.. ..... __no Duets in unCOfJditi9.D.e.d alti~:.~~ min. Insulation. - --'-'-'\~ ,...... OJ .....,... ~-_.- <br />I-!Y~9...9ontrols ____. ._~p~.1 . .. Seoarete reaq!!y'_ac.cessi~~__mal}~al or automatic thermoslilt f<;lr ~~~..:!Y.!!t~!I'~. _.. ...h___.. <br />Insulation 604.1, 602.1 Ceilings-Min, R.19. Common walls-Frame R-11 or CBS R.3 both sides. I <br /> Common ceiling & floors R-11, <br /> ,j I <br /> <br />EnergyGauge"Tll DCA Form 600A-2004R <br /> <br />EnergyGaugel8l/FlaRES'2004R FlRCSB v4.5.2 <br />