<br />1 D-cm-o: Glqzing-Double pane, operable window, clear,
<br />metal frame no break, outdoor insect screen with
<br />50% coverage, u-value 0.87
<br />11 G: Door-Panel
<br />13A-4ocs: Wall-Block, board insulation only, R-4 board
<br />insulation, open core, siding finish
<br />12B-Osw: Part-Frame, R-11 insulation in 2 x 4 stud cavity,
<br />no board insulation, siding finish, wood studs
<br />i 16C-30: Roof/Ceiling-Under attic or knee wall, Vented
<br />I Attic, No Radiant Barrier, White or Light Color
<br />Shingles, Any Wood Shake, Light Metal, Tar and
<br />Gravel or Membrane, R-30 insulation
<br />22A-pm: Floor-Slab on grade, No edge insulation, no
<br />insulation below floor, any floor cover, passive, heavy
<br />dry or light wet soil
<br />
<br />Subtotals for structure:
<br />People:
<br />Equipment:
<br />Lighting:
<br />Ductwork:
<br />Infiltration: Winter CFM: 51, Summer CFM: 25
<br />Ventilation: Winter CFM: 0, Summer CFM: 0
<br />
<br />System 1 House Load Totals:
<br />
<br />257
<br />
<br />8,498
<br />
<br />o
<br />
<br />13,297
<br />
<br />13,297
<br />
<br />63
<br />1589
<br />
<br />1,146
<br />8,634
<br />
<br />960
<br />
<br />o
<br />o
<br />
<br />987
<br />4,612
<br />
<br />960
<br />
<br />987
<br />4,612
<br />
<br />960
<br />
<br />395.5
<br />
<br />o
<br />
<br />1973
<br />
<br />2,399
<br />
<br />o
<br />
<br />2,841
<br />
<br />2,841
<br />
<br />
<br />Supply CFM:
<br />Square ft. of Room Area:
<br />Volume (ft3) of Condo Space:
<br />
<br />193 8,655 0 0 0
<br /> 30,292 0 22,697 22,697
<br />7 1 ,400 1,610 3,010
<br /> 1,400 1 ,400 2,800
<br />0 0 0
<br /> 9,627 1,724 8,175 9,899
<br /> 2,114 801 556 1,357
<br /> 0 0 0 0
<br /> 42,033 5,325 34,438 39,763
<br />CFM Per Square ft.:
<br />Square ft. Per Ton:
<br />Air Turnover Rate (per hour):
<br /> MBH
<br /> %
<br /> %
<br /> Tons (Based On Sensible + Latent)
<br />
<br />
<br />Total Heating Required With Outside Air:
<br />Total Sensible Gain:
<br />Total Latent Gain:
<br />Total Cooling Required With Outside Air:
<br />
<br />Calculations are based on 8th edition of ACCA Manual J.
<br />All computed results are estimates as building use and weather may vary.
<br />Be sure to select a unit that meets both sensible and latent loads.