Laserfiche WebLink
<br />Subsidence Investigation <br />Mathewl Aley Rental Property <br />Claim No. 223968 <br /> <br />BCI Project No. 03-15564 <br />November 2007 <br />Page 8 <br /> <br />3.2 Laboratory Testing <br /> <br />Laboratory tests for natural moisture content (ASTM Standard 02216) and percent passing a No. 200 <br />sieve (ASTM Standard 01140) were completed on selected samples from the SPT borings. In general, the test <br />results were in good agreement with the field classifications, with the exception that some of the samples were <br />reclassified due to minor differences in fines content. The test data are summarized below in Table 2. <br />Laboratory test reports are included in Appendix C. <br /> <br />Table 2 <br />Laboratory Test Results <br />Mathew/Aley Rental Property <br /> <br />Sample Stratum % Moisture % -200 <br />Content Sieve <br />SPT-l, 13Y2 to 15 ft. 2 19.2 13.9 <br />SPT-l, 33Y2 to 35 ft. 5 26.2 16.3 <br />SPT-2, 13Y2 to 15 ft. 3 26.2 55.4 <br />SPT-2, 28Y2 to 30 ft. 3 34.1 32.8 <br />SPT-3, 8 to 10 ft. 3 11.8 13.8 <br />SPT-3, 18Y2 to 20 ft. 2 16.3 8.6 <br /> <br />Notes: Sample depths shown in feet below grade <br />Borehole locations shown on Figure 2 <br />