Permit #
08-7884
Building Department - Name
BRUNNER,JUDITH
Address
6623 NORTH LADE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Trinitv Glass International <br /> <br />NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br /> <br />A. DRAWINGS <br />1. Manufacturer's die drawings and sections. <br />2. Drawing No S-2582, Sheets 1 through 9 of 9, titled "3'0 x 6'8 Glazed Premium <br />Fiberglass Door Inswing 'Non-Impact' ", dated 08/17/05, prepared by RW Building <br />Consultants, Inc., signed and sealed by Lyndon F. Schmidt, P.E. <br /> <br />B, TESTS <br />1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 <br />2) Uniform Static Air Pressure Test, Loading per FBC T AS 202-94 <br />3) Water Resistance Test, per FBC, T AS 202-94 <br />4) Forced Entry Test, per FBC 3603.2 (b) and TAS 202-94 <br />along with marked-up drawings and installation diagram of 3'0 x 6'8 "Premium <br />Glazed Fiberglass Door, prepared by Testing Evaluation Laboratories, Inc., Test <br />Report No. TEL-05-0907-1, dated 09/07/05, signed and sealed by Wendell W. Haney. <br /> <br />C, CALCULATIONS <br />1. Anchor verification calculations and structural analysis, complying with FBC-2004, <br />dated 09/15/05, prepared by RW Building Consultants, Inc., signed and sealed by <br />Lyndon F. Schmidt, P.E. Complies with ASTM E1300-02 <br /> <br />D. QUALITY ASSURANCE <br />1. Miami Dade Building Code Compliance Office (BCCO). <br /> <br />E. MATERIAL CERTIFICATIONS <br />1. Test Report No. ETC-05-781-17122.0, prepared by ETC Laboratories., issued to <br />Trinity Glass International, dated 10/19/05, Polyurethane Foam, tested per ASTM <br />D2843 "Self Ignition Temperature"; ASTM E84 "Flame Spread Index", ASTM E84 <br />"Smoke Developed Index", signed and sealed by Joseph Labora Doldan, P.E. <br />2. Notice of Acceptance No. 05-1206.01 issued to Trinity Glass International, for their <br />Unfinished Fiberglass Door Skin approved on 03/02/06 and expiring on 03/02111. <br />3. Notice of Acceptance No. 02-0429,11 issued to Trinity Glass International, for their <br />Trinity Lite Frame approved on 07/3/02 and expiring on 07/03/07. <br /> <br />F. STATE~NTS <br />1. Statement letter of conformance and no financial interest, dated 09/15/05, signed and <br />sealed by Lyndon Schmidt, P.E. <br />2. Statement letter of no financial interest, dated 07/21/05, signed by Andrew Na. <br /> <br />G. OTHER <br />1. Letter from the consultant, dated November 10, 2005, stating that the product is <br />compliance with the Florida Building Code (FBC . <br /> <br /> <br />~anuei P.E. <br />Product Con i er <br />NOA No -0922.03 <br />Expiration Date: April 27. 2011 <br />Approval Date: April 27 . 2006 <br /> <br />E.} <br />