Laserfiche WebLink
<br />. <br />~ <br /> <br />Architectural Testing <br /> <br />62609.01-501-47 <br />Page 5 of 10 <br /> <br />Test Results: The results are tabulated as follows: <br />Paragraph Title of Test - Test Method Results Allowed <br />Test Specimen #1: H-LC25 1118 x 1956 (44 x 77) <br />2.2.1.6.1 Operating Force <br />5.3.1.1 <br /> Bottom Sash <br /> Open 230 N (50 lbs) <br /> Breakaway 67 N (15 lbs) <br /> Maintain motion 89 N (20 lbs) 155 N (35 Ibs) <br /> Close <br /> ,Breakaway 36 N (8Ibs) 230 N (50 Ibs) <br /> Maintain motion 45 N (10 lbs) 155 N (35 lbs) <br /> Top Sash <br /> ~ <br /> Breakaway 27 N (6Ibs) 230 N (50 Ibs) <br /> Maintain motion 89 N (20 lbs) 155 N (35 Ibs) <br /> Close <br /> Breakaway 53 N (12 lbs) 230 N (50 lbs) <br /> Maintain motion 80 N (18Ibs) 155 N (35Ibs) <br /> Lock <br /> Open 5 N (lIb) J 00 N (22.5 Ibs) <br /> Close 5N(1Ib) 100 N (22.5Ibs) <br /> Latches <br /> Open 5N(1Ib) 100 N (22.5 Ibs) <br /> <br />2.1.2 Air Leakage Resistance per ASTM E 283 (See Note #1) <br />5.3.2 75 Pa (1.57 psf, 25 mph) 1.1 L/s/m2 1.5 L/sim2 <br />(0.21 cfin/~) (0.30 cfinl~) max. <br /> <br />Note #1: The tested specimen meets (or exceeds) the performance levels specified in <br />ANSI/AAMAINWWDA 1 01lL S. 2-97, lOl/LS.2/NAFS-02, AAMA/WDMAlCSA lOllLS. <br />2/A440-05 for air infiltration. <br />