<br />.. <br />~ <br /> <br />Architectural Testing <br /> <br />Test Results: (Continued) <br /> <br />Paragraph Title of Test - Test Method <br /> <br />Results <br /> <br />Test Specimen #1: H-LC25 1118 x 1956 (44 x 77) (Continued) <br /> <br />2.2.1.6.2 <br />5.3.6.3 <br /> <br />DeglazingTest per ASTM E 987 <br /> <br />Tol' Sash <br />In operating direction - 320 N (70 Ibs) <br />Meeting rail 1.5 nun.(0.06") <br />Top rail 1.5 nun (0.06") <br /> <br />In remaining direction - 230 N (50 lbs) <br />Left stile 0.8 nun.(0.03") <br />Right stile 0.8 nun (0.03 It) <br /> <br />'> <br /> <br />Bottom Sash <br />In operating direction - 320 N (70 lbs) <br />Meeting rail 1.5 nun:(0.06") <br />Bottom rail 1.5 nun(0.06") <br /> <br />In remaining direction - 230 N (50 Ibs) <br />Left stile 0.8 mm;(0.03") <br />Right stile 0.8 mm,(0.03") <br /> <br />Optional Performance <br /> <br />4.3 <br />4.4.3.4 <br /> <br />Water Resistance per ASTM E 547 <br />(with and without screen) <br />440 Pa (9.0 pst) No leakage <br /> <br />62609.01-501-47 <br />Page 7 of 10 <br /> <br />Allowed <br /> <br />11.43.mm (0.45") <br />11.43 nun (0.45") <br /> <br />11.43 nun (0.45") <br />11.43 nun (0.45") <br /> <br />11.43 nun (0.45") <br />11.43 rom (0.45") <br /> <br />11.43 nun (0.45") <br />11.43 nun (0.45") <br /> <br />No leakage <br />