<br /> <br />STEEl <br /> <br /> <br />PEDTE<:"nON <br /> <br />10.18 <br /> <br /> <br />SERIES 705W <br />WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE <br /> <br />SWITCH AND WIRING <br /> <br />1. The supervisory switch contains two, single pole, double throw, pre-wired switches, <br /> <br />2, Switches are rated: <br /> <br />10 ar~ps @ 125 or 250 VAC/60 Hz <br /> <br />0:,0 amps @ 125 VDC <br /> <br />0,25 amps @ 250 VDC <br /> <br />3. Switches supervise the valve in the "open" position, <br /> <br />4, One switch has two #18 MTW wires per terminal, which permit complete supervision of leads <br />(refer to diagrams and notes below), The second switch has one #18 MTW wire per termll,al. <br />This double circuit provides flexibility to operate two electrical devices at separate locations, <br />such as an indicating light and an audible alarm, in the area that the valve is installed. <br /> <br />5. A #14 MTW ground lead (green) is provided. <br /> <br />Switch #1 = Sl For connection to the supervisory circuit of a UL <br />Listed alarm control panel <br /> <br />Switch #2 = S2 Auxiliary switch that may be connected to auxiliary <br />devices, per the authority having jurisdiction <br /> <br />S1 <br /> <br />{ <br />{ <br /> <br />Normally Closed: (2) Blue <br />Common: (2) Yellow <br /> <br />52 <br /> <br />Normally Closed: Blue with Orange Stripe <br />Normally Open: Brown with Orange Stripe <br />Common: Yellow with Orange Stripe <br /> <br />COND;.!1 <br /> <br />~r/ <br /> <br />~ou"co"'(Jm; <br /> <br /> <br /> <br />':>',/-;11(1-' <br />CQ'IIA(l'.tAf,N(, <br />iO,\,\TolSM;D <br />)~,(lV,\C <br />OY,ATi2SV:=<, <br />O}'ji'IhOI,r,X- <br /> <br />J' <br /> <br />VOlTt,0f:;[IUR(( <br /> <br />Swltc:h1:]lel>d5~rterrninal <br />Swltth2:11l"adperterminal <br /> <br />NOTE: The above diagram shows a connection between the common terminal (yellow - Sl and <br />yellow-with-orange stripe - S2) and the normally closed terminal (blue - Sl and blue-with-orange <br />stripe - S2), In this example, the indicator light and alarm will stay on until the valve is fully open, <br />When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires <br />(e.g. brown with orange stripe). <br /> <br />Only Sl (two leads per terminal) may be connected to the fire alarm control panel. <br /> <br />The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary <br />switch per NFPA 70 (NEC). <br /> <br />www.victaulic.com <br />VICTAULlC IS A REGISTERED TRADEMARK OF VICTAUlIC COMPANY, <<:> 2006 VICTAUlIC COMPANY, ALL RIGHTS RESERVED, PRINTED IN THE USA, <br /> <br />~taulic' <br />V.i_~"""""^.....,_y.,..___:...".~",,, <br /> <br />HEV f <br />