<br />April 6, 2007 <br /> <br />Sprinkler 120e <br /> <br />'11K1NGj <br /> <br />TECHNICAL DATA <br /> <br />ESFR PENDENT SPRINKLER <br />VK500 (K14.0) <br /> <br />The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 <br />Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com <br /> <br />4. INSTALLATION <br /> <br />WARNING: Viking sprinklers are manufactured and tested to meet rigid requirements of the approving agency. The sprinklers are <br />designed to be installed in accordance with recognized installation standards. System design must be based on ESFR design <br />guidelines described in the latest edition of Viking technical data, applicable FM Giol,ql Loss Prevention Data Sheets, the latest <br />NFPA Standards, the latest standards of Verband der Sachversicherer (VdS), Loss Prevention Council (LPCB), the Authorities <br />Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards whenever applicable, Deviation <br />from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, <br />or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The <br />Viking Corporation. <br /> <br />A. Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container, Never install <br />sprinklers that have been dropped or damaged in any way, Such sprinklers should be destroyed immediately. NOTE: Wet pipe <br />systems must be provided with adequate heat. <br /> <br />B. The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the <br />appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. <br /> <br />C. With the sprinkler contained in the plastic protective cap, apply a small amount of pipe-joint compound or tape to the male threads <br />only, while taking care not to allow a build-up of compound in the sprinkler orifice. <br /> <br />0, Use ONLY sprinkler wrench 10285W/B or 13635W/B (shown in Figure 1) for installing ESFR Sprinkler VK500! With the <br />sprinkler contained in the protective cap, install the sprinkler onto the piping by applying the sprinkler wrench to the <br />sprinkler wrench flats only, while taking care not to damage the sprinkler operating parts. <br /> <br />. DO NOT use any other -type of wrench, as this could damage the unit. <br /> <br />. DO NOT use the sprinkler deflector or fusible element to start or thread the sprinkler into a fitting. <br /> <br />. DO NOT exceed 50 ft. Ibs. of torque (hand tight, plus approximately two full turns with the wrench) to install these sprinklers. <br />Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. <br /> <br />E, After installation, the entire sprinkler system must be tested, The test must be conducted to comply with the Installation Standards. <br />Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint <br />compound or tape applied, and then reinstalled, This is due to the fact that when the joint seal is damaged, the sealing compound <br />or tape is washed out of the joint. Immediately replace any damaged units, using the special sprinkler wrench only. <br /> <br />F, After installation and testing and repairing of all leaks, remove the protective caps from the sprinklers. Do NOT use any <br />type of tool to remove the cap. Remove the cap by hand: turn it slightly and pull it off the sprinkler. When removing caps, <br />use care to prevent dislodging or damaging sprinkler ejector spring and fusible element. THE CAPS MUST BE REMOVED <br />FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! <br /> <br />G. System design must be based on ESFR design guidelines described in applicable FM Global Loss Prevention Data Sheets, the latest <br />standards of Verband der Sachversicherer, LPCB, the National Fire Protection Association, and the Authorities Having Jurisdiction. <br />All requirements of recognized sprinkler system design standards apply to systems utilizing Viking ESFR Pendent Sprinklers. <br />NOTE: Viking recommends installing one style of sprinklers (either pendent or upright) throughout ESFR systems. <br />However, provided the fusible elements are installed within the distance below the ceiling allowed by the installation <br />standards, and when acceptable to the Authority Having Jurisdiction, Viking considers the practice of mixing upright <br />and pendent ESFR sprinklers to be acceptable. <br /> <br />5. OPERATION <br />During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open the <br />waterway, Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattem to suppress the fire, <br />