Laserfiche WebLink
<br />. <br />~ <br /> <br />Architectural Testing <br /> <br />62609.01-501-47 <br />Page 5 of 10 <br /> <br />Test Results: The results are tabulated as follo~s: <br />Paralp"aph Title of Test - Test Method Results Allowed <br />Test Specimen #1: H-LC25 1118 x 1956 (44 x77) I,' <br />2.2.1.6.1 Operating Force <br />5:3.1.1 <br /> Bottom Sash <br /> Qmm 67 N (15 lbs) 230 N (50 lbs) <br /> Breakaway . <br /> Maintain motion 89 N (20 lbs) 155 N (35 Ibs) <br /> Close 230 N (50 lbs) <br /> Breakaway 36 N (8 lbs) <br /> > Maintain motion 45 N{10 lbs) 155 N (35 lbs) <br /> Top Sash <br /> Qmm 230 N (50 Ibs) <br /> Breakaway 27 N (6.1bs) <br /> Maintain motion 89 N (201bs) 155 N (35 lb.s) <br /> " , <br /> Close , <br /> Breakaway 53 N (12 lbs) 23Q N (50 lbs) <br /> Maintain motion 80 N (18Ibs) 155 N (35 lbs) <br /> I&gk <br /> Open 5N(1Ib) 100 N (22,5 lbs) <br /> Close 5 N (lIb) 100 N (22.5lbs) <br /> Latches <br /> Open 5N (lIb) 100 N (22.5Ibs) <br /> <br />2.1.2 Air Lealq1ge Resistance per ASTM E 283 (See Note #1) <br />5.3.2 75 Pa (1.57 psf, 25.mph)' 1.1 L/s/m2 1,5 L/s/m2 <br />(0.21 c1in/fl?) (0,30 cfinlfl?) max. <br /> <br />Note ~1: The tested specimen meets' (or exceeds) th~ perform~nce levels specified in <br />ANSI/AAMA/NWWDA 1 0111. S. 2-97, 10lI1.S.2/NAFS-02, AAMA/WDMA/CSA 1 01/1 S. <br />2/A440-05 for air infiltration. <br />