My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-8047
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-8047
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2008 10:36:11 AM
Creation date
10/22/2008 8:38:03 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-8047
Building Department - Name
TOWNVIEW RETAIL LLC
Address
7346 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Specifications <br />PHYSICAL SPECIRCATIONS: <br /> <br /> pull station 5B-IIO 5B-10 <br />Height 5.5 inches 5.601 inches 5.5 inches <br />(13.97 em) (14.23 em) (13.97 em) <br />Width 4.121 inches 4222 in:hes 4.121 inches <br />(10.47 em) (10.72 em) (10.47 em) <br />Depth 1.39 inches 1.439 inches 1.375 inches <br />(3.53 em) (,3.66 em) (3.49 em) <br /> <br />52004dim.tli <br /> <br />ELECTRICAL SPEC/FICA TlONS: <br /> <br />Switch contact ratings: gold-plated: rating 0.25 A @ 30 VAC or <br />VDC. <br /> <br />ENGINEERING/ARCHITECTURAL SPEClF1CA nONS <br /> <br />Manual Fire Alarm Stations shall be non-code. with a key- or <br />hex-operated reset lock in order tha1they may be tested, and so <br />designed that after actual Emergency Opera1ion, they cannot be <br />restored to normal except by use of a key or hex. An operated <br />station shall automatically condition itself so as to be visually <br />detected as activated. Manual stations shall be constructed of <br />red colored LEXAN (or polycarbonate equivalent) with clearly <br />visible operating instructions provided on the cover. The word <br />FIRE shall appear on the front of the stations in white letters. <br />1.00 inches (2.54 em) or larger. Stations shall be suitable for <br />surface mounting on ma1ching backbox 58-10 or S8-1/0; or <br />semi-flush mounting on a standard single-gang, double-gang, or <br />4" (10.16 em) square electrical box. and shall be installed within <br />the limits defined by the Americans with Disabilities Act (ADA) or <br />per nationaVlocal requirements. Manual Stations shall be Under- <br />writers Laboratories listed. <br />NOTE: 'The words "FIRE/FUEGO" on the BG-12LSP shall appear <br />on the front of the station in white /etters, approximately 314. <br />(1.905 em) high. <br /> <br /> <br />Agency Listings and Approvals <br /> <br />The listings and approvals below apply to the BG-12 Series pull <br />stations. In some cases, certain modules may not be listed by <br />certain approval agencies, or listing may be in process. Consult <br />factory for latest listing sta1us. <br />. C{UL)US: 8711 <br />. FM Approved <br />· CSFM: 7150-0075:184 <br />. MEA: 67-Q2-E <br />. Patented: U.S. Patent No. 0428,351; 6,380.846; 6.314,772: <br />6.632,108. <br /> <br />Product Line Information <br /> <br />BG-12S: Single-action pull station with pigtail connections, hex <br />lock. <br />BG-12SL: Same as BG-12 with key leek. <br />BG-12: Dual-action pull station with SPST N/O switch, screw <br />terminal connections, hex lock. <br />BG-12L: Same as BG-12 with key lock. <br />BG-12LSP: Same as BG-12L with English/Spanish (FIRE! <br />FUEGO) labeling. <br />BG-12LOB: 8ame as BG-12L with "outdoor use" listing. <br />Includes outdoor listed backbox. and sealing gasket. <br />BG-12LO: Same as BG-12L with "outdoor use" listing. Does <br />not include backbox. <br />BG-12LA: Same as 8G-12L with auxiliary contacts. <br />BG-12LPS: Dual-action pull station with pre-signal option. <br />BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE! <br />FUEGO) labeling. <br />SB.10: Surface-mount backbox, metal. <br />SB-1I0: Surface-mount backbox. plastic. (Included with BG- <br />12LOB.) <br />BG12TR: Optional trim ring for semi-flush mounting. <br />17003: Keys. set of two. (Included with key-lock pull stations.) <br />17007: Hex lock, 9/64". (Included with hex-lock pull stations.) <br />NOTE: For addressable BG-12LX models, see data sheet DF- <br />52013. <br /> <br />FireoLitee Alanna, SpectrA~ Advance, and System Sensor@ are <br />registered trademarks of Honeywell International Inc. <br />@2OOS by Honeywelllntemalionallnc. All rights reserved. Unau1horized use <br />ollhis document is strictly prohibited. <br /> <br />~ <br /> <br />_II <br /> <br />ISO 9001 <br /> <br />-,,=-"-_.~.=-.]I <br />_'~Al"" <br />...un SYSTEMS <br /> <br />This document is not intended to be used for installation purposes. <br />We try to keep our product information up-to-<late and accurate. <br />We cannot cover all specifie applications or anticipate all requirements. <br />All specifications are subject to change without notice. <br /> <br />~ <br /> <br />Made in the U.S. A. <br /> <br />- <br /> <br />For more information, contact Fire-Lite Alarms. Phone: (BOO) 627-3473, FAX: (an) 699-4105. <br />www.firelite.com <br /> <br />---, <br /> <br />Page 2 of 2 - DF-52004:A 1 . 04l221OB <br /> <br />~ <br /> <br />'""'~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.