My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-8121
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-8121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2008 10:39:59 AM
Creation date
10/22/2008 8:52:26 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-8121
Building Department - Name
HEALTH RESOURCES AP INC
Address
37918 MEDICAL ARTS CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />Fire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />July 29, 2008 <br /> <br />Plan Review Comments <br /> <br />I have reviewed and approved the plan for an interior remodel located at 37944 Medical <br />Arts Ct Wlder the following conditions. My comments have been placed below. Please <br />contact me if you have any questions with regards to my comments. <br /> <br />1. Install panic hardware on all secondary exits, <br />2. Smoke detectors shall be installed in corridors outside utility, break room and <br />storage related areas, Detectors shall be hardwired with battery backup and tied <br />together. <br />3. Exit signs shall show direction of travel and be turned to be visibly read. <br />4, You can not exit through a utility/storage room Therefore that can not cOWlt as an <br />exit. This limits your common path of travel. You are not to exit through a kitchen <br />either, but I will allow an egress through a break room I believe that is what the <br />room was meant for. Label the room appropriately. However, to meet the <br />common path of travel 75 ft, (38.2.5,3.3 ofNFP A 101) a wall shall be built to <br />make a corridor through the utility and a door placed in the utility to enter that <br />space. <br />5, The attic shall have a smoke separation every 3000 sq ft. <br />6. AlC units with a greater CFM of 2000 s~l have duct detectors that are resettable. <br />Key switch is fine. <br />7. Fire walls shall be fire caulked at roof deck, all penetrations properly sealed in <br />accordance with the code and stenciled "FIREWALL - DO NOT PENETRATE", <br />8. Address front of building (6" numbering) <br />9, Certified fire extinguisher required per NFP A 10 every 75 ft of travel distance. <br />10. A Knox Box system is preferred. An application can be obtained from Zephyrhills <br />Fire Rescue at the address above. <br /> <br />Inspections required: (call inspections into building department) <br /> <br />1. Fire wall inspect, (screw and final) <br />2. Building final. <br />
The URL can be used to link to this page
Your browser does not support the video tag.