My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-8166
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-8166
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2008 10:43:46 AM
Creation date
10/22/2008 9:04:09 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-8166
Building Department - Name
PHIL MOOK ENT. INC
Address
5506 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ELECTRICAL GAS VALVES <br /> <br />.The electrical gas valves are designed to shut off the flow of either <br />natural or LP gas to the appliances upon actuation of the regulat- <br />ed release assembly. The valves are available in sizes of 3/4 in., <br />1 in., 1 1/2 in., 2 in., and 3 in. The valve is held open by an ener- <br />gized solenoid and upon system actuation, the switch contacts in <br />the regulated release assembly open, thus de-energizing the cir- <br />cuit to the gas valve solenoid, causing the valve to close. Valves <br />are available in 120 VAC and are UL Listed. <br /> <br />Part <br />No. <br /> <br />.. 13707 <br />13708 <br />13709 <br />13710 <br />17643 <br /> <br />Description <br /> <br />3/4 in. Solenoid Gas Valve (ASCO) <br />1 in. Solenoid Gas Valve (ASCO) <br />1 1/2 in. Solenoid Gas Valve (ASCO) <br />2 in. Solenoid Gas Valve (ASCO) <br />3 in. Solenoid Gas Valve (ASCO) <br /> <br />Max. Operating <br />Pressure <br /> <br />25 psi (1.7 bar) <br />25 psi (1.7 bar) <br />25 psi (1.7 bar) <br />25 psi (1.7 bar) <br />5 psi (.35 bar) <br /> <br />Valve A B <br />Size in. (mm) in. (mm) <br />3/4 in. 3 5/16 (81.0) 35/8 (92.1 ) <br />1 in. 5 (127.0) 6 27/32 (173.8) <br />1 1/2 in. 5 (127.0) 5 19/32 (142.1 ) <br />2 in. 6 3/32 (78.6) 5 15/16 (150.8) <br />3 in. 7 13/16 (198.4) 7 29/32 (200.8) <br /> I <br /> B <br /> I <br /> <br /> <br />.. <br /> <br />.. FIGURE 26 <br />004210 <br /> <br />MANUAL RESET RELAY <br /> <br />The manual reset relay, Part No. 14702 or Part No. 426151, is <br />required when using an electrical gas valve shut-off system. After <br />the electric gas valve has closed, either due to system actuation <br />or power failure, the valve cannot be re-opened, allowing gas to <br />flow, until the reset relay button is manually pressed, re-energizing <br />the circuit. The reset relay is available 120 VAC. The manual reset <br />relay is also recommended for electrical shut down. <br /> <br /> <br />FIGURE 27 <br />0000117 <br /> <br />SECTION 11I- SYSTEM COMPONENTS <br />UL EX. 3470 ULC CEx747 Page 3-9 <br />3-1-04 REV. 3 <br /> <br />ELECTRICAL SWITCHES <br /> <br />The electrical switches are intended for use with electric gas <br />valves, alarms, contactors, lights, contractor supplied electric <br />power shut-off devices and other electrical devices that are <br />designed to shut off or turn on when the system is actuated. <br /> <br />Switches are available in kits: One Switch Kit, Part No. 423878, <br />Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. <br />.. 423880, and Four Switch Kit, Part No. 423881. Mounting hard- <br />ware and 12 in. (305 mm) long wire leads are provided with each <br />kit. Each switch has a set of single-pole, double-throw contacts <br />rated at: <br /> <br />UUcUUCSA Rating <br />250 VAC, 21A Resistive <br />250 VAC, 2 HP <br />..125 VAC, 1 HP <br /> <br />ENEC Rating <br />IE4T105~ Approved <br />250V, 21A Resistive <br />8A Motor Load <br /> <br /> <br />/N.O. <br /> <br />N.C. <br /> <br />FIGURE 28 <br />001612 <br /> <br />ALARM INITIATING SWITCH <br /> <br />The Alarm Initiating Switch Kit, Part No. 428311, can be field <br />mounted within the ANSUL AUTO MAN release. This switch must <br />be used to close a supervised circuit to the building main fire alarm <br />panel when the ANSUL AUTOMAN release actuates. This action <br />will signal the fire alarm panel that there was a system actuation in <br />the kitchen area. The switch kit contains all necessary mounting <br />components along with a mounting instruction sheet. The switch is <br />rated 50 mA, 28 VDC. <br /> <br />.. <br /> <br />TOWARD ANSUL <br />AUTOMAN <br />" <br /> <br /> <br />WHEN SPACER AND <br />SWITCH ARE PROPERLY <br />MOUNTED, THIS DIVIDER <br />MUST BE BETWEEN THE <br />/ N.O. AND N.C. TERMINALS <br /> <br /> <br />/COM <br /> <br />/N.O. <br /> <br />......,,- <br /> <br />....... <br /> <br /> <br />ALARM INITIATING <br />SWITCH <br /> <br />FIGURE 29 <br />004690 <br />
The URL can be used to link to this page
Your browser does not support the video tag.