<br />(~~~x/ ) <br />EROL/ <br /> <br />Certificate of <br />Authorization #9503 <br /> <br />Evaluation Report 01506.11.05 <br />GAF Materials Corporatit:ln, ttsliso <br />Date of Issuance: 11/07/2005 <br />Page 4 of 5 <br /> <br />Installation Requirements: <br /> <br />1. GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF published installation <br />instructions, subject to the Limitations / Conditions of Use noted below. <br /> <br />2. System attachment requirements for wind load resistance are set forth in Appendix 1. <br /> <br />Limitations / Conditions of Use: <br /> <br />1. This Evaluation Report is not for use within the HVHZ. <br /> <br />2. Refer to a current Approved Roofing Materials Directory for surfacing requirements and fire rating. <br /> <br />3. For steel deck installations, foam plastic insulation shall be separated from the building interior in <br />accordance with FBC Section 2603.4 unless the exceptions stated in FBC Sections 2603.4.1 and <br />2603.8 apply. <br /> <br />3. Unless otherwise noted in Appendix 1, roof decking and its attachment shall be specified and <br />installed to meet project design criteria to the satisfaction of the AHJ. <br /> <br />4. For recover installations, the existing roof shall be examined in accordance with FBC Section 1510. <br /> <br />5. For mechanically attached components, the maximum design pressure for the selected assembly <br />shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. <br />Zones 2 and 3 shall employ a tighter component attachment density designed by a qualified design <br />professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM <br />LPDS 1-29. <br /> <br />6. For adhered insulation, the maximum design pressure for the selected assembly shall meet or <br />exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis <br />is permitted for these systems. <br /> <br />7. For mechanically attached com ponents over existing roof decks, fasteners shall be tested in the <br />existing deck for withdrawal resistance. A qualified design professional shall review the data for <br />comparison to the minimum requirements for the system. Testing and analysis shall be in <br />accordance with TAS 105. <br /> <br />8. For adhered insulation over existing substrates, the existing deck or roof surface shall be examined <br />for compatibility with the membrane or insulation adhesive to be installed. If any surface conditions <br />exist that bring system performance into question, field uplift testing in accordance with ASTM E907 <br />or FM LPDS 1-52 shall be conducted on mock-ups of the proposed new roof assembly. <br /> <br />9. For recover installations, the existing roof system shall be capable of resisting project design <br />pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing <br />in accordance with ASTM E907 or FM LPDS 1-52. <br /> <br />Certification of Independence: <br /> <br />1. ERD East does not have, nor does it intend to acquire or will it acquire, a financial interest in any <br />company manufacturing or distributing products it evaluates. <br />2. ERD East is not owned, operated or controlled by any company manufacturing or distributing <br />products it evaluates. <br />3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company <br />manufacturing or distributing products for which the evaluation reports are being issued. <br />4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved <br />in the approval process of the product. <br /> <br />MAIN: 2412 7th Ave W . Suite 101. Seattle, WA 98119. P: (206) 467-0054. F: (206) 467-5840 <br />EAST: 2 Mattoon Road. Waterbury, CT 06708. P: (203) 596-7884. F: (203) 596-7058 <br />lAB: 600 W. Nickerson Street. Seattle, WA 98119. P: (206) 298-3620. F: (206) 298-3130 <br /> <br />~;d) <br /> <br />TL-199 Certified <br />