<br />~ <br /> <br />@) Flre,uTe" ALarms <br /> <br />March 30,2000 <br /> <br />G-250 <br /> <br />SpectrAlert ™ Series <br />Horns, Strobes, and Horn/Strobes <br /> <br />GENERAL <br /> <br />Section: AudioNisual Devices <br /> <br />System Sensor SpectrAlert Series strobes, horns, and combina- <br />tion horn/strobes are UL listed for primary signaling in life safety <br />systems and meet ADA public mode visible signaling requirements. <br /> <br />SpectrAlert products can be connected to the alarm indicating cir- <br />cuit of a fire alarm control panel and are compatible with DC line <br />supervision. The SpectrAlert product line mounts to standard <br />backboxes using a universal mounting plate included with each unit. <br />An optional small footprint mounting plate fils to a single-gang box. <br />An accessory backbox skirt gives a cosmetic finish to a 4' x 4" x <br />1-1/2' or a 2' x 4' x 1-7/8' surface-mounted backbox. All strobe <br />and horn/strobe mounting options require only one screw attach- <br />ment of product to plate. <br /> <br />These products are designed for 12 and 24 VDC and full-wave rec- <br />tified unfiltered power. Full-wave rectified operation requires more <br />current than DC operation. For detailed current draw information, <br />consult the Current Draw Tables (page 2). The horn/strobe com- <br />bination products are factory-assembled with jumper wires for in- <br />tandem operation. For independent wiring of horn and strobe, re- <br />move jumper wires. When wired for independent operation, the <br />strobe will continue to run while the horn can be silenced. How- <br />ever, the strobe must be running for horn to operate. <br /> <br />Horns - The SpectrAlert Series horns and horn/strobes pro- <br />vide two different field-selectable/reversible tones, a high-low field- <br />selectable/reversible sound output setting (low setting on 24-volt <br />models only) and a field-selectable/reversible temp 3 pattern or <br />non-temporal continuous pattern. These field-selectable features <br />are accomplished using pins and jumpers located on the back of <br />each SpectrAlert horn and hom/strobe. An accessory module is <br />not needed to make these field selections. The hom on horn/strobe <br />models will operate on a coded power supply. Those horn-only <br />models with "He" in their part numbers will a/so operate on a <br />coded power supply. The hom and horn/strobe series includes <br />weatherproof models. <br /> <br />Strobes - The ADA-compliant SpectrAlert strobes are elec- <br />tronic visible warning signals that flash at 1 Hz over their operating <br />vDltage range. These products are available in 24-volt models at <br />15, 15n5, 75 and 110 candela intensities and in 12-volt models at <br />15 and 15n5 candela intensities. The strobe series includes weath- <br />erproof models. SpectrAlert products feature dramatic reductions <br />in current requirements. <br /> <br />Sync-Circuit Module (MOL) - The Sync-Circuit Mod- <br />ule is available for synchronization of strobes and horns and can <br />synchronize two Style Y (class B) circuits or one Style Z (class A) <br />circuit. The module can also generate a synchronized temp 3 tone <br />for System Sensor's Multi-Alert™ and PA400 horn products: The <br />synchronization module allows the SpectrAlert horns on combina- <br />tion horn/strobes to be silenced on two-wire systems. SpectrAlert's <br />Sync-Circuit Module can be daisy-chained for multiple zone syn- <br />chronization. The module does not operate on a coded power sup- <br />ply. <br /> <br />'For Multi-Alert and PA400: Strobes must be wired to a continuous <br />source of power (non-coded power supply). <br /> <br />@L.....S4011&S5512(P1215,P121575P2415 <br />@ P241575, P2475, P24110). 55512 (S1215.' <br />S121575, 82415, S241575, S2475. S24110). <br />LISTED S4011 (HC12/24). <br /> <br />@ ~ CS549 (P2415A, P241575A, P2475A, P24110A, <br />S2415A, 8241575A, S2475A, S24110A). <br />U LC CS548 (H12/24A. HC12/24A). <br /> <br />088A4.AY (P1215, P121575, ~ ~ <br />P2415,P241575, P2475,P24110, ~ <br />81215,8121575, S2415, 8241575, <br />82475,824110, H12/24). OD4A7.A Y (HC12124). <br /> <br /> <br />..... 7135-1209:173 (P1215, P121575, P2415, <br />P241575, P2475, P24110). <br />7125-1209:174 (81215, S121575, <br />82415,8241575, S2475, 824110). <br />7135-1209:143 (H12124. HC12/24). <br /> <br />California <br />State Fire <br />Marshal <br /> <br />MEA..... 319-96-E (P1215,P121575, <br />P2415.P241575,P2475, <br />P24110, 81215,8121575, <br />82415,8241575,82475, <br />824110, Hl2124, HC12/24). <br /> <br /> <br />to <br />~ <br />Q. <br />'" <br />o <br />'" <br />'" <br /> <br />SpectrAlert™, Sync'Circuit™, and Multi-Alert™ are trade- <br />marks of System Sensor, a division of Pittway Corporation. <br /> <br />This document is not Intended to be used for installation purposes. We try to keep our product <br />information up. to-date and accurate. We cannot cover all specific applications or anticipate all <br />requirements. All specifications are subject to change wilhout nolice.. For more information, <br />contact Fire-Lite Alarms, One Fire-Lite Place. Northford. Connecticut 06472. Phone: (800) 627- <br />3473. Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299 <br />WEB: www.firelile.com <br /> <br />ISO 9001 <br /> <br />I[ ~ =4: ~ II I=-. =4 .] <br />ENCINtERINC & MANUFACTlBINC <br /> <br />DF-S1609 - Page 1 or 6 <br />