My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
FIRST UNION NATIONAL BANK 38421 5TH AVE.
Zephyrhills
>
Building Department
>
Building Plans
>
FIRST UNION NATIONAL BANK 38421 5TH AVE.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2010 3:08:39 PM
Creation date
3/23/2010 2:53:29 PM
Metadata
Fields
Template:
Building Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AD <br />AFF <br />BFF <br />BOT <br />CLG <br />co <br />CW <br />EQUIP <br />EWC <br />EXIST <br />FD <br />FL <br />GCO <br />HB <br />HW <br />S <br />TYP <br />LION <br />V <br />VIF <br />W <br />wco <br />ABBREVIATIONS <br />ACCESS DOOR <br />ABOVE FINISHED FLOOR <br />BELOW FINISHED FLOOR <br />BOTTOM <br />CEILING <br />CLEANOU T <br />COLD WATER <br />EQUIPMENT <br />ELECTRIC WATER COOLER <br />EXISTING <br />FLOOR" DRAIN <br />FLOOR <br />GRADE CLEANOUT <br />HOSE BIBB <br />HOT WATER <br />SANITARY <br />TYPICAL <br />UNLESS OTHERWISE NOTED <br />VENT <br />VERIFY IN FIELD <br />WASTE <br />WALL CLEANOUT <br />PLUMBING <br />............. <br />EXISTING PIPE TO REMAIN <br />EXISTING PIPE TO BE REMOVED <br />SOIL OR WASTE PIPE <br />VENT PIPE <br />COLD WATER <br />HOT WATER <br />GAS PIPE <br />CLEANOUT EXPOSED <br />CLEANOUT IN FLOOR <br />HAMMER ARRESTOR (POI SIZE INDICATED) <br />DIRECTION OF FLOW <br />ANCHOR <br />CAPPED OUTLET <br />RISE OR DROP IN PIPE <br />UNION <br />GATE VALVE <br />GLOBE VALVE <br />CHECK VALVE <br />BALL VALVE <br />HOSE BIB6 <br />ABBREVIATIONS, LEGENDS AND GENERAL NOTES <br />DRAWING SYMBOLS <br />POINT OF INTERFACE BETWEEN NEW & EXISTING <br />POINT OF DEMOLITION <br />POINT OF INTERFACE BETWEEN CONTRACTORS <br />NOTE: <br />THESE ARE STANDARD SYMBOLS AND MAY NOT ALL APPEAR ON THE PROJECT DRAWINGS; HOWEVER <br />WHEREVER THE SYMBOL APPEARS ON THE PROJECT DRAWINGS, THE ITEM SHALL BE PROVIDED AND INSTALLED. <br />GENERAL NOTES <br />CONTRACTOR SHALL PROVIDE COMPLETE PLUMBING 'SYSTEMS AS DETAILED ON THESE DRAWINGS. <br />WORK CONSISTS OF FURNISHING ALL MATERIALS, EQUIPMENT, AND SERVICES REQUIRED FOR <br />COMPLETE SYSTEMS. INCLUDE ANY INCIDENTAL AFT ARATUS, APPLIANCES, MATERIAL LABOR AND <br />SERVICES NECESSARY TO MAKE NEW WORK COMPLE:`E IN ALL RESPECTS AND FULLY READY FOR <br />OPERATION. <br />2. ALL PLUMBING WORK SHALL BE DESIGNED, INSTALLE), TESTED, AND CLEANED IN ACCORDANCE <br />MTH SBCCI STANDARD PLUMBING CODE REQUIREMENTS. <br />3. VERIFY THE EXACT LOCATION OF EXISTING SOIL, WASTE, VENT, HOT AND COLD WATER PIPING <br />FROM THE ACTUAL JOB SITE. ALL NEW LINES ARE TO BE ROUTED TO AND /OR FROM VERIFIED <br />LOCATIONS, TAPS, WHEN NOT PROVIDED BY PRFVICUS INSTALLER, ARE TO BE PROVIDED BY THIS <br />INSTALLER. <br />4. MAKE SUCH OFFSETS AND DE0AT1ONS FROM WORK SHOWN ON THE DRAWINGS, AS MAY BE <br />NECESSARY TO FIT THE ACTUAL SPACE CONDITION'S <br />5. WHERE VALVES OCCUR ABOVE SHEET ROCK CEIL Nc. ;1; OR ARE CONCEALED BEHIND WALLS, THIS <br />CONTRACTOR SHALL FURNISH AND INSTALL ACCE :S`:; PANELS. PANELS SHALL MATCH EXISTING. <br />6. THE INSTALLER SHALL VISIT THE JOB SITE AND NSF'ECT ALL EXISTING CONDITIONS AFFECTING THE <br />WORK. SUBMISSION OF HIS PROPOSAL SHALL BE CONSTRUED AS INDICATING SUCH KNOWLEDGE. <br />NO ADDITIONAL PAYMENT WILL BE MADE ON CLAIMS THAT ARISE FROM T}1E CONTRACTOR'S <br />FAILURE TO COMPLY WITH THIS REQUIREMENT. <br />7, THE PLANS AND DIAGRAMS OF PLUMBING PIPING ARE SCHEMATIC ONLY AND SHOULD NOT BE <br />SCALED. INSTALLER SHALL COORDINATE AT SITE V1TH ALL PLUMBING, HVAC, FIRE PROTECTION, <br />MEDICAL GASES, AND ELECTRICAL WORK SO AS NOT TO CONFLICT IN LOCATION WITH OTHER WORK <br />UNDER THIS CONTRACT OR THAT MAY BE EXISTING. <br />8. PROVIDE AND MAINTAIN TEMPORARY CONNECTIONS 10 KEEP EXISTING UTILITIES IN SERVICE. ANY <br />SHUT DOWNS ARE TO BE APPROVED BY OWNER'S R:PRESENTAIIVE. <br />9. EXACT LOCATION NUMBER AND TYPE OF PLUMBING =1XTURES SHALL BE DETERMINED FROM <br />ARCHITECTURAL DRAWINGS. VERIFY SUCH LOCATIONS BEFORE PROCEEDING ROUGH —IN. <br />10. INSTALLER SHALL NOT CUT ANY EXISTING STRUCRF'AL MEMBERS WITHOUT FIRST SECURING <br />WRITTEN APPROVAL FROM THE ARCHITECT. <br />11. PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS I3ETWEEN DISSIMILAR PIPING METALS. <br />12, FIELD VERIFY ALL EXISTING PIPE SIZES PRIOR TC' INSTALLATION. <br />13. NO VENT THRU ROOF SHALL TERMINATE CLOSER TH .V■ 10 FT. TO ANY OUTSIDE AIR INTAKE. <br />14, PIPING IN CONCRETE BLOCK WALLS SHALL BE INSTALLED AS BLOCK IS BEING LAID. DO NOT CUT <br />BLOCK WALL. <br />15. PROVIDE ALL SINKS AND LAVATORIES W1TH SLIP JOIAT TRAP FITTINGS FOR CLEANOUT. <br />16. PROVIDE ALL REFRIGERATORS WITH A 3/8" COLD W >TER SUPPLY FOR AN ICE MAKER. TERMINATE <br />SUPPLY BEHIND REFRIGERATOR AT APPROX. 12' A F.F. MTH A CHROME PLATED STOP. SEE <br />ARCHITECTURAL DRAWINGS FOR LOCATIONS OF REFFIGERATORS, <br />17. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO IDENTIFY ABOVE CEILING CONFLICTS. THE <br />CONTRACTOR IS RESPONSIBLE TO ALSO CHECKING F ELD CONDITIONS PRIOR TO BIDDING AND <br />REPORT ANY PROBLEMS /CONFLICTS TO THE ENGINE: :E R WITHIN 2 DAYS OF DISCOVERY. ANY <br />CHANGES RESULTING FROM CONDITIONS ARISING IN HE FIELD WHICH WERE NOT BROUGHT TO THE <br />ENGINEER'S ATTENTION ARE TO BE MADE BY THIS CONTRACTOR WITH NO ADDITIONAL COST TO THE <br />OWNER. <br />18. ALL WORK IS TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE(1) <br />YEAR FROM DATE OF FINAL ACCEPTANCE. ALL DEFECTS WHICH DEVELOP OR ARE DISCOVERED <br />WITHIN THIS PERIOD SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE <br />OWNER AT NO ADDITIONAL COST TO THE OWNER. <br />19. UPON COMPLETION OF THE WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL REMOVE ALL <br />TOOLS, APPLIANCES, SURPLUS MATERIALS, AND SCRAP. ALL IDENTIFIED EXISTING EQUIPMENT TO <br />BE REMOVED SHALL BE TURNED OVER TO THE C"I:R, <br />20. WHEN CONFLICTS OCCUR IN SPECIFICATIONS OR N ' HE DRAWINGS, OR BETWEEN EITHER, THE ITEMS <br />OF GREATER QUANTITY OR HIGHER COST SHALL BE PROVIDED. <br />21. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID CONFLICTS. <br />NM • <br />Notes: <br />Revisions: <br />Consultants: <br />'"E -- <br />1E3c <br />M E BITS <br />BOSEK, GIBSON & ASSOCIATES <br />ENGINEERING CONSULTANTS <br />508 W. FLETCHER AVENUE <br />TAMPA. FLORIDA 33412 <br />OPT'ICS:(8l3) 980 -3399 FAX:(813) 969 -0920 <br />E -MAIL: bgatpaejte.net <br />ARCHITECTS •INTERIOR DESIGNERS <br />"*Z.:;,-. /1 •00 <br />1. <br />\ 14 ■i i ■ <br />/"<6."\ \':***41*ftft*P. <br />J <br />99255 <br />The Edgewater Building <br />600 South Magnolia Avenue <br />Suite 150 <br />Tampa, Florida 33606 <br />Phone (813) 251-0565 <br />Fax (813) 251 -0567 <br />P -1 <br />First Union Notional Bonk <br />of Florida <br />ZEPNYRNILLS <br />38421 STN AVENUE <br />ZEPNYRNILLS, FLORIDA <br />Drawing No. /Dote 3 MAY 1999 <br />Drawing Title /Scale /Drawn by W.J.C. <br />LEGEND, ABBREVIATIONS, <br />AND GENERAL NOTES <br />SCALE: NOT TO SCALE <br />SL Dom": <br />
The URL can be used to link to this page
Your browser does not support the video tag.