TYPE MANUFACTURER CATALOG NO. <br />A LITHONIA 2SPG02– U31 –Al2 -120 <br />Al SAME AS A EXCEPT PROVIDE WITH <br />EMERGENCY BALLAST <br />8 LITHONIA EJ -2 -32 -120 <br />C KURTVERSEN P602 –SC –EB <br />C1 SAME AS C EXCEPT PROVIDE WITH <br />EMERGENCY BALLAST <br />LITHONIA LED -1 –RC- 1201277 <br />EX -1 <br />NOTES: <br />0 PROVIDE ELECTRONIC BALLAST <br />0 PROVIDE EMERGENCY BALLAST <br />LIGHTING FIXTURE SCHEDULE <br />VOLTS NO. OF LAMP LAMP <br />LAMPS WATTS TYPE <br />120 2 31 TB <br />DESCRIPTION <br />120 2 31 18 2'X2' RECESSED FLUOR. TROFFER <br />120 2 32 T8 4' FLOUR, INDUSTRIAL FIXTURE <br />120 2 26 PL SURFACE MTD FLUOR FIXTURE <br />120 2 26 PL <br />120 – – LED TOP MOUNTED EXIT SIGN <br />0 <br />0 <br />0 <br />0 <br />0 <br />REMARKS <br />GENERAL NOTES: <br />THE CONTRACTOR SHALL PROVIDE AND MAKE OPERAT1ONAL THE ELECTRICAL <br />SYSTEMS & EQUIPMENT ASSOCIATED WITH THE WORK DESCRIBED IN THE BID <br />DOCUMENTS FOR THIS PROJECT. <br />2. ALL CONDUITS St- ALL BE 3/4" UNLESS OTHERWISE INDICATED <br />3. ALL WIRING SHALL. BE RUN CONCEALED UNLESS OTHERWISE SPECIFIED. <br />4, EXACT LOCATION OF HVAC Sc PLUMBING EQUIPMENT THAT REQUIRE ELECTRICAL <br />CONNECTIONS ART: SHOWN ON THE HVAC & PLUMBING DRAWINGS. <br />5. THE CONTRACTOR SHALL COORDINATE THE EXACT LOCATION AND ROUGHING IN <br />DIMENSIONS OF ALL EQUIPMENT AND SHALL MAKE ALL FINAL CONNECTIONS AS <br />REQUIRED, I.E., POWER, CONTROL, INTERLOCK, ETC. <br />6. `IRE AND CONDUIT SIZES INDICATE ON HOMERUNS SHALL BE CONTINUOUS <br />THROUGH CIRCUIT. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL <br />OUTLETS INDICATED WITH CIRCUIT NUMBERS AND PANEL DESIGNATIONS, <br />7. ALL SWITCH CON ROLS SHALL BE PROVIDED WITH WIRING AND CONDUIT AS <br />REQUIRED. <br />8. ALTHOUGH ALL BRANCH CIRCUIT W1RE AND CONDUIT IS NOT SHOWN, IT IS THE <br />INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WRING <br />SYSTEM BE INSTF LLED. <br />9. THE ELECTRICAL :ON TRACTOR SHALL FURNISH AND INSTALL ALL INCIDENTAL <br />ACCESSORIES NECESSARY TO MAKE THE ELECTRICAL WORK COMPLETE AND <br />READY FOR OPERATION. <br />10. DRAWINGS ARE D AGRAMMATIC ONLY: EXACT LOCATION, MOUNTING HEIGHTS OF <br />EQUIPMENT AND ?OUTING OF RACEWAYS SHALL BE COORDINATED WITH THE <br />EQUIPMENT RFQU REMENTS AND FIELD CONDITIONS. <br />11. THE CONTRACTCF SHALL PROVIDE AND INSTALL ALL NECESSARY SUPPORTS AND <br />HARDWARE FOR HOUNTING OF ELECTRICAL EQUIPMENT. <br />12. THE ENTIRE ELECTRICAL SYSTEM SHALL BE TESTED FOR PROPER GROUNDING AND <br />OPERATION PRICF TO FINAL ACCEPTANCE AS SPECIFIED IN THE BID <br />SPECIFICATIONS 4 ND /OR AS SPECIFIED HEREIN. TESTS SHALL VERIFY THAT THE <br />ENTIRE ELECTRICAL SYSTEM HAD NO SHORT– CIRCUITS, OPENS, OVERLOADS, OR <br />PANEL UNBALANCES. ALL EQUIPMENT AND WIRING SYSTEMS SHALL BE <br />GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE N.E.C. <br />13, ALL ELECTRICAL MATERIALS AND EQUIPMENT FURNISHED FOR THIS PROJECT <br />SHALL BE NE ' AND APPROVED BY U.L., EXCEPT WHERE NOTED. <br />14, FOR ADDITIONAL 'REQUIREMENTS, THE CONTRACTOR SHALL REFER TO DRAWING <br />AND BID SPECIFICATIONS. <br />15. ALL ELECTRICAL WORK TO BE DONE IN ACCORDANCE WITH THE LATEST NATIONAL <br />ELECTRICAL COCE AND LOCAL CODES WHERE APPLICABLE. <br />16. ALL FLUORESCENT FIXTURES SHOW ARE RELOCATED UNLESS NOTED OTHERWISE. <br />17, ALL SHADED rLU)RESCENT LIGHTING FIXTURES SHALL BE CONTROLLED BY A <br />SWITCH AS INDICATED ON FLOOR PLAN AND ALSO CONNECTED TO LINE SIZE OF <br />LOCAL SWITCH FOR PROPER EMERGENCY BALLAST OPERATION. <br />18, ALL TYPE "EX" L GHTING FIXTURES SHALL BE CONNECTED TO CIRCUIT INDICATED <br />AHEAD OF LOCAL SWITCH. <br />19. CONTRACTOR TO PROVIDE ALL NEW ELECTRONIC BALLASTS FOR ALL <br />FLUORESCENT FI ›TURES UNDER THIS PROJECT AND PROVIDE EMERGENCY BALLAST <br />FOR THOSE FIX1LRES THAT ARE GOING TO BE EMERGENCY LIGHTS. <br />20. ALL NEW 2`X2' FLUORESCENT FIXTURES ARE TO BE TYPE 'A' UNLESS OTHERWISE <br />NOTED ON DWGS (SEE LIGHTING FIXTURE SCHEDULE FOR DESCRIPTION OF TYPE <br />'A' FIXTURES) <br />!OEM <br />Revisions: <br />Seal: <br />Consultants: <br />BOSEK, GIBSON & ASSOCIATES <br />ENGINEERING CONSULTANTS <br />508 11. F1ZTC H ER AVENUE <br />TAMPA. FLORIDA 33812 <br />OPPICE:(6 960 -3999 PAX:(513) 964 -0920 <br />E -MAIL: b`atpa•gte.net <br />E ENTS <br />ARCHITECTS .INTERIOR DESIGNERS <br />\***>%•%•/-WiN:" <br />7- ay I 4N <br />I 7A 3".. c 1 <br />Vo \ aft. <br />"<"•.:\ X > <br />The Edgewater Building <br />600 South Magnolia Avenue <br />Suite 150 <br />Tampa, Florida 33606 <br />Phone (813) 251 -0565 <br />Fax (813) 251 -0567 <br />First Union Notional Bank <br />o f Florida <br />ZEFNYRNILLS <br />38421 5TH AVENUE <br />ZEPPYRNILLS, FLORIDA <br />Drawing No. /Date <br />E- <br />99255 <br />3 MAY 19 <br />Drawing Title /Scale /Drawn by W.J.C. <br />LEGEND, GENERAL NOTES <br />AND LIGHTING SCHEDULE <br />SCALE: NOT TO SCALE <br />BL DGi: <br />ELECTRICAL SYMBOL LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />O <br />CEILING MOUNTED LIGHT FIXTURE, LETTER INDICATES TYPE. LOWER CASE LETTER <br />INDICATES SWITCH CONTROL. <br />SEE FIXTURE SCHEDULE <br />• <br />SAME AS ABOVE EXCEPT EMERGENCY BRANCH, NO SWITCH CONTROL. <br />SEE FIXTURE SCHEDULE <br />2'x4' FLUOR FIXTURE <br />' FLUOR, FIXTURE <br />El FLUORESCENT <br />FIXTURE ON EMERGENCY BRANCH. <br />SEE FIXTURE SCHEDULE <br />EXIT LIGHT CEILING MOUNTED <br />S <br />SINGLE POLE TOGGLE SWITCH. LOWER CASE LETTER INDICATES LIGHTING CONTROLLED. <br />M.H. 4' -0" TO CENTERLINE; <br />FLOOR OUTLET BOX W /(3) IG DUPLEX, (1) VOICE /DATA OUTLET. <br />FLUSH MTD TO FLOOR <br />10 lo <br />DUPLEX RECEPTACLE, 20A 125V. <br />�Pot <br />.H. 'LI <br />B V�(/E COUNTER <br />U.O.N. <br />DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER. <br />DUPLEX RECEPTACLE, 20A 125V, <br />M.H. 4' -0" TO CENTERLINE, <br />M.H. 18° TO CENTERLINE <br />U.O.N. <br />. ;. <br />DOUBLE DUPLEX RECEPTACLE, 20A 125V. <br />M.H. 4' -0" TO CENTERLINE <br />DOUBLE DUPLEX RECEPTACLE, 20A 125V. <br />TWO CELL SURFACE METAL RACEWAY, WITH SEPARATE CELLS FOR POWER RECEPTACLES <br />AND VOICE /DATA, WIREMOLD G6000 SERIES WITH REQ'D SUPPORT, <br />MTD BELOW COUNTER <br />CEILING MOUNTED DUPLEX RECEPTACLE, 20A 125V, <br />_ . <br />DATA /TELEPHONE OUTLET. PROVIDE 3/4 "C EMPTY CONDUIT STUB –UP SUSP. CEILING.— <br />FLUSH CEILING <br />�'$� 11�E LI N <br />UM ,ON .N. <br />V <br />AS INDICATED <br />MI <br />ELECTRICAL PANELBOARD <br />1 1 <br />LA-1.3 <br />HOMERUN TO PANEL BOARD INDICATED. LETTERS INDICATE PANEL, NUMBERS INDICATE <br />CIRCUIT(S). ALL HOMERUNS SHALL HAVE A GROUND AND NEUTRAL CONDUCTOR. UNLESS <br />OTHERWISE NOTED PROVIDE #12 AWG CU CONDUCTORS AS REQUIRED FOR CIRCUITS <br />SHOWN. ALL CONDUITS SHALL BE SIZED PER CODE. MINIMUM 3/4 "C. IT SHALL BE <br />PERMISSIBLE TO GROUP A MAXIMUM OF THREE CIRCUITS WITH NEUTRAL AND EQUIPMENT <br />GROUND PER HOMERUN. <br />SEE SPECIFICATIONS <br />— <br />•�-- -_.-- -- <br />CONDUIT CONCEALED IN CEILING SPACE OR WALL MINIMUM 3/4 ". UNLESS OTHERWISE <br />NOTED PROVIDE #12 AWG CU CONDUCTORS AS REQUIRED FOR CIRCUITS SHOWN. <br />PROVIDE EQUIPMENT GROUND CONDUCTOR SIZED AS PER N.E.C. <br />SEE SPECIFICATIONS <br />— <br />CONDUIT UNDERGROUND ON 3/4" C. UNLESS OTHERWISE NOTED. PROVIDE <br />#12 AWG CU CONDUCTORS AS REQUIRED FOR CIRCUITS SHOWN. ALL CONDUITS SHALL <br />BE SIZED PER CODE. MINIMUM 3/4 "C. IT SHALL BE PERMISSIBLE TO GROUP A MAXIMUM <br />OF THREE CIRCUITS WITH NEUTRAL AND EQUIPMENT GROUND PER HOMERUN. <br />SEE SPECIFICATIONS <br />JUNCTION BOX OR OUTLET BOX, SIZE AS REQUIRED PER N.E.C. <br />0 <br />DRY TYPE TRANSFORMER. <br />a <br />FIRE ALARM MANUAL PULL STATION. <br />M,H. 4' - TO CENTER <br />SMOKE DETECTOR <br />CEILING MOUNTED <br />1 0 <br />FIRE ALARM STROBE <br />MOUNT 80" ABOVE FLOOR <br />OR 6" BELOW CEILING, <br />WHICHEVER IS LOWER <br />FIRE ALARM CONTROL PANEL. <br />FACF <br />8 <br />COMBINATION FIRE ALARM CHIME /STROBE <br />MOUNT 80" ABOVE FLOOR <br />OR 6" BELOW CEILING, <br />WHICHEVER IS LOWER <br />Q <br />P.A. SPEAKER <br />FA <br />SECURITY KEY PAD <br />�� <br />CEILING MTD. SECURITY CAMERA <br />EWC <br />EXISTING TO REMAIN <br />(E) <br />EXISTING TO REMAIN <br />(N) <br />NEW ITEM <br />IG <br />ISOLATED GROUND <br />AFF, <br />ABOVE FINISHED FLOOR <br />N.I.C. <br />NOT IN CONTRACT <br />(R) <br />EXISTING ITEM TO BE REMOVED <br />(RL) <br />EXISTING ITEM TO BE RELOCATED <br />TYPE MANUFACTURER CATALOG NO. <br />A LITHONIA 2SPG02– U31 –Al2 -120 <br />Al SAME AS A EXCEPT PROVIDE WITH <br />EMERGENCY BALLAST <br />8 LITHONIA EJ -2 -32 -120 <br />C KURTVERSEN P602 –SC –EB <br />C1 SAME AS C EXCEPT PROVIDE WITH <br />EMERGENCY BALLAST <br />LITHONIA LED -1 –RC- 1201277 <br />EX -1 <br />NOTES: <br />0 PROVIDE ELECTRONIC BALLAST <br />0 PROVIDE EMERGENCY BALLAST <br />LIGHTING FIXTURE SCHEDULE <br />VOLTS NO. OF LAMP LAMP <br />LAMPS WATTS TYPE <br />120 2 31 TB <br />DESCRIPTION <br />120 2 31 18 2'X2' RECESSED FLUOR. TROFFER <br />120 2 32 T8 4' FLOUR, INDUSTRIAL FIXTURE <br />120 2 26 PL SURFACE MTD FLUOR FIXTURE <br />120 2 26 PL <br />120 – – LED TOP MOUNTED EXIT SIGN <br />0 <br />0 <br />0 <br />0 <br />0 <br />REMARKS <br />GENERAL NOTES: <br />THE CONTRACTOR SHALL PROVIDE AND MAKE OPERAT1ONAL THE ELECTRICAL <br />SYSTEMS & EQUIPMENT ASSOCIATED WITH THE WORK DESCRIBED IN THE BID <br />DOCUMENTS FOR THIS PROJECT. <br />2. ALL CONDUITS St- ALL BE 3/4" UNLESS OTHERWISE INDICATED <br />3. ALL WIRING SHALL. BE RUN CONCEALED UNLESS OTHERWISE SPECIFIED. <br />4, EXACT LOCATION OF HVAC Sc PLUMBING EQUIPMENT THAT REQUIRE ELECTRICAL <br />CONNECTIONS ART: SHOWN ON THE HVAC & PLUMBING DRAWINGS. <br />5. THE CONTRACTOR SHALL COORDINATE THE EXACT LOCATION AND ROUGHING IN <br />DIMENSIONS OF ALL EQUIPMENT AND SHALL MAKE ALL FINAL CONNECTIONS AS <br />REQUIRED, I.E., POWER, CONTROL, INTERLOCK, ETC. <br />6. `IRE AND CONDUIT SIZES INDICATE ON HOMERUNS SHALL BE CONTINUOUS <br />THROUGH CIRCUIT. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL <br />OUTLETS INDICATED WITH CIRCUIT NUMBERS AND PANEL DESIGNATIONS, <br />7. ALL SWITCH CON ROLS SHALL BE PROVIDED WITH WIRING AND CONDUIT AS <br />REQUIRED. <br />8. ALTHOUGH ALL BRANCH CIRCUIT W1RE AND CONDUIT IS NOT SHOWN, IT IS THE <br />INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WRING <br />SYSTEM BE INSTF LLED. <br />9. THE ELECTRICAL :ON TRACTOR SHALL FURNISH AND INSTALL ALL INCIDENTAL <br />ACCESSORIES NECESSARY TO MAKE THE ELECTRICAL WORK COMPLETE AND <br />READY FOR OPERATION. <br />10. DRAWINGS ARE D AGRAMMATIC ONLY: EXACT LOCATION, MOUNTING HEIGHTS OF <br />EQUIPMENT AND ?OUTING OF RACEWAYS SHALL BE COORDINATED WITH THE <br />EQUIPMENT RFQU REMENTS AND FIELD CONDITIONS. <br />11. THE CONTRACTCF SHALL PROVIDE AND INSTALL ALL NECESSARY SUPPORTS AND <br />HARDWARE FOR HOUNTING OF ELECTRICAL EQUIPMENT. <br />12. THE ENTIRE ELECTRICAL SYSTEM SHALL BE TESTED FOR PROPER GROUNDING AND <br />OPERATION PRICF TO FINAL ACCEPTANCE AS SPECIFIED IN THE BID <br />SPECIFICATIONS 4 ND /OR AS SPECIFIED HEREIN. TESTS SHALL VERIFY THAT THE <br />ENTIRE ELECTRICAL SYSTEM HAD NO SHORT– CIRCUITS, OPENS, OVERLOADS, OR <br />PANEL UNBALANCES. ALL EQUIPMENT AND WIRING SYSTEMS SHALL BE <br />GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE N.E.C. <br />13, ALL ELECTRICAL MATERIALS AND EQUIPMENT FURNISHED FOR THIS PROJECT <br />SHALL BE NE ' AND APPROVED BY U.L., EXCEPT WHERE NOTED. <br />14, FOR ADDITIONAL 'REQUIREMENTS, THE CONTRACTOR SHALL REFER TO DRAWING <br />AND BID SPECIFICATIONS. <br />15. ALL ELECTRICAL WORK TO BE DONE IN ACCORDANCE WITH THE LATEST NATIONAL <br />ELECTRICAL COCE AND LOCAL CODES WHERE APPLICABLE. <br />16. ALL FLUORESCENT FIXTURES SHOW ARE RELOCATED UNLESS NOTED OTHERWISE. <br />17, ALL SHADED rLU)RESCENT LIGHTING FIXTURES SHALL BE CONTROLLED BY A <br />SWITCH AS INDICATED ON FLOOR PLAN AND ALSO CONNECTED TO LINE SIZE OF <br />LOCAL SWITCH FOR PROPER EMERGENCY BALLAST OPERATION. <br />18, ALL TYPE "EX" L GHTING FIXTURES SHALL BE CONNECTED TO CIRCUIT INDICATED <br />AHEAD OF LOCAL SWITCH. <br />19. CONTRACTOR TO PROVIDE ALL NEW ELECTRONIC BALLASTS FOR ALL <br />FLUORESCENT FI ›TURES UNDER THIS PROJECT AND PROVIDE EMERGENCY BALLAST <br />FOR THOSE FIX1LRES THAT ARE GOING TO BE EMERGENCY LIGHTS. <br />20. ALL NEW 2`X2' FLUORESCENT FIXTURES ARE TO BE TYPE 'A' UNLESS OTHERWISE <br />NOTED ON DWGS (SEE LIGHTING FIXTURE SCHEDULE FOR DESCRIPTION OF TYPE <br />'A' FIXTURES) <br />!OEM <br />Revisions: <br />Seal: <br />Consultants: <br />BOSEK, GIBSON & ASSOCIATES <br />ENGINEERING CONSULTANTS <br />508 11. F1ZTC H ER AVENUE <br />TAMPA. FLORIDA 33812 <br />OPPICE:(6 960 -3999 PAX:(513) 964 -0920 <br />E -MAIL: b`atpa•gte.net <br />E ENTS <br />ARCHITECTS .INTERIOR DESIGNERS <br />\***>%•%•/-WiN:" <br />7- ay I 4N <br />I 7A 3".. c 1 <br />Vo \ aft. <br />"<"•.:\ X > <br />The Edgewater Building <br />600 South Magnolia Avenue <br />Suite 150 <br />Tampa, Florida 33606 <br />Phone (813) 251 -0565 <br />Fax (813) 251 -0567 <br />First Union Notional Bank <br />o f Florida <br />ZEFNYRNILLS <br />38421 5TH AVENUE <br />ZEPPYRNILLS, FLORIDA <br />Drawing No. /Date <br />E- <br />99255 <br />3 MAY 19 <br />Drawing Title /Scale /Drawn by W.J.C. <br />LEGEND, GENERAL NOTES <br />AND LIGHTING SCHEDULE <br />SCALE: NOT TO SCALE <br />BL DGi: <br />