Laserfiche WebLink
Uata ►rieet 2108 <br /> Engineered Systems <br /> IPF Series TM <br /> Discovery Thermal <br /> Detector j <br /> DIC.T • <br /> description <br /> The AsBuilt intelligent analog addressable thermal detector (DISC -T) y w <br /> operates seamlessly with the AsBuilt IP Fire Series TMA network fire control. <br /> The DISC -T communicates to and is managed and controlled by the IPF <br /> Series TM analog loop module (ALM). <br /> DISC -T heat detectors have a common profile with the photoelectric and Features <br /> ionization smoke detectors but have a low air flow resistance case made <br /> of self extinguishing white polycarbonate. The DISC- f has two red colored • Discovery detectors distribute <br /> LED's that light steady when in an alarm condition and flash briefly when intelligence across the installed <br /> polled by the ALM. The dual LED's provide for 360 degree visibility. system <br /> Operation <br /> • Sleek, non - fading white <br /> polycarbonate enclosure <br /> The DISC -T heat detector uses a single thermistor to sense the air • Zero insertion force base <br /> temperature at the detector position. The thermistor is connected in a • 5 user selectable modes combine <br /> resistor network, which produces a voltage output dependant on static response with rate - of - rise <br /> temperature. features <br /> The design of the resistor network, together with the processing algorithm • Powerful transient rejection <br /> in the microcontrolier, gives an approximate linear temperature algorithms <br /> • <br /> characteristic. This signal is further processed, depending on the response Conventional device mode <br /> mode selected, and converted to an analog output for transmission to the • Patented XPert programming card <br /> ALN1, eliminates addressing errors during <br /> Upon crossing the alarm threshold the detector will make the system installation and maintenance <br /> determination that an alarm condition exists and send a signal to the ALM • Al a rm flag sends signal to system <br /> that interrupts the normal polling the even when device is not being <br /> p g process to signal th„ alarm condition. interrogated <br /> The ALM puts the changed state on the IP network and all outputs • associated with the specific detector are activated. Wide variety of addressable <br /> input /output devices <br /> Like all Discovery devices, the DISC -T has five pre-programmed user • Relay and synchronized temporal <br /> settings that may be accessed and changed from the IPF Series network sounder bases <br /> control. Further, the pre - programmed settings are utilized in establishing <br /> the automatic temperature response values in place with the IPF <br /> Day/Night sensitivity programming. <br /> With DISC -T heat detectors, the five user modes correspond to different ! Listings <br /> combinations of fixed temperature settings with or without rate -of- rise <br /> (ROR) features. UL File: S5022 <br /> CSFM: 7270 - 1394:119 <br /> Settings are classified as static (S) if it incorporates fixed temperature MEd: 294 95 - - <br /> settings only. With this setting, the detector will not respond below its <br /> minimum static response temperature even when exposed to high rates of <br /> rise of air temperature. This type of setting is therefore suitable for areas <br /> such as kitchens or boiler rooms where large, rapid temperature changes <br /> ara rnnsiriprpri nnrmal <br /> Product Data Sheet Number Rev /Revision Date <br /> IPF Series TM Detectors DISC -T 2108 1 21 1/1/'2009 s SEmE <br /> IP /IRE RIES" <br /> © Copyright 2008 AsBuilt Engineered Systems, Inc. — <br />