Deck Type 1I: Wood, Insulated <br /> Deck Description: 19 / 32 " or greater plywood or wood plank <br /> System Type D: All layers of insulation and base sheet simultaneously attached. <br /> All General and System Limitations apply. <br /> Insulation Layer Insulation Fasteners Fastener <br /> (Table 3) Density /ft <br /> AC FOAM II, AC FOAM III <br /> Py oZ E'N RG'Y 111.P. _�� 1Atr iCs..l r <br /> Fli t:mune � av- , oam I inter Panel, �� <br /> Expanded Polystyrene ri' High Density Wood Fiber, Extruded or <br /> Minimum 134" thick N/A NIA <br /> Note: Insulation layer shall be mechanically attached with fasteners and density described above. <br /> Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of <br /> fasteners per board shall be increased maintaining the same fastener density (See Roofing <br /> Application Standard RAS 117 for fastening details). <br /> Membrane with 25" tabs: Duro-Last membrane shall be mechanically attached at its 6" wide tabs, <br /> spaced every 25" o.c. with Duro -Last #15 EHD Screws with Duro-Last Cleat <br /> Plates or ITW Buildex 2 -3/8" Eyehook Plates spaced 6" o.c. maximum, <br /> through the insulation and into the deck. Duro-Last Tab Sealant 4725 shall <br /> be applied over the tab membrane and to the overlying membrane underside <br /> at a rate of 60 ft2/gal (two-sided application). <br /> (Maximum Design Pressure -97.5 psf; See General Limitation #7) <br /> Membrane with 57" tabs: Duro -Last membrane shall be mechanically attached at its 6" wide tabs, <br /> spaced every 57" o.c. with Duro-Last HD Screws (#14) with Duro-Last 3- <br /> inch Metal Plates spaced 6" o.c. maximum, through the insulation and into <br /> the deck. Duro-Last Tab Sealant 4725 shall be applied over the tab <br /> membrane and to the overlying membrane underside at a rate of 60 ft2/gal <br /> (two-sided application). <br /> (Maximum Design Pressure -S2.5 psf; See General Limitation # 7J <br /> Duro -Last membrane shall be mechanically attached at its 6" wide tabs, <br /> spaced every 57" o.c. with Duro-Last EHD Screws (I/15) with Duro-Last <br /> Cleat Plates or ITW Buildex 2 -3/8" Eyehook Plates spaced 6" o.c. <br /> maximum, through the insulation and into the deck. Fastener -line located <br /> 2.7 -inch from tab edge. <br /> (Maximum Design Pressure -52.S psf; See General Limitation #7J <br /> Membrane with 60" tabs: Duro-Last membrane shall be mechanically attached at its 3" wide tabs, <br /> spaced very 60" o:c with HD Screws (#1 with Duro- Last — Pay <br /> Plates spaced 6" o.c. maximum, through the insulation and into the deck. <br /> Duro -Last Tab Sealant 4725 shall be applied over the tab membrane and to <br /> the overlying membrane underside at a rate of 60 ft2/gal (two-sided <br /> application). <br /> ( Maximum Design Pressure -45.0 <br /> Maximum Design Psl: See General Limitation #7) <br /> l See fastening above <br /> Pressure: <br /> NOA No.: <br /> Expiration Date: 08/22/ 0822/12 <br /> Approval Date: 02/21/08 <br /> Page 8 of 10 <br />