Laserfiche WebLink
SECTION III – SYSTEM COMPONENTS <br /> UL EX. 3470 ULC CEx747 Page 3 -7 <br /> . 10 -1 -02 REV.4 <br /> CLIP -ON STYLE - PART NO. 56837 AND 56838 <br /> i DETECTORS <br /> The detector consists of three basic components: the bracket, link- <br /> age, and fusible link. (Fusible links are not included and must be <br /> ordered separately.) The bracket holds the entire assembly to the FUSIBLE <br /> LINKAGE <br /> I ' mounting surface. The linkage is used to support the fusible link. <br /> LINK <br /> BRACKET <br /> The fusible link is designed to separate at a specific temperature ...... <br /> and release the wire rope, thereby actuating the regulated release <br /> mechanism. —71. 000157 <br /> f There are three styles of detectors available: the clip -on style, the HINGED STYLE - PART N0.15373 AND 15375 <br /> hinged style, and the scissor style. <br /> The clip -on style allows the wire rope to be strung completely Q' <br /> 1 through the detection system conduit and brackets first and the <br /> L INKAGE <br /> detector linkage assemblies are then clipped on later. FUSI <br /> LINK BRACKET <br /> The hinged style detector requires the wire rope to be strung to the <br /> detector bracket, and then "threaded" through the linkage assem- <br /> 1 bly before continuing to the next detector bracket. m re <br /> 1.....4 <br /> The scissor style allows the wire rope to be strung completely 000158 <br /> through the detection system conduit and brackets first and the SCISSOR STYLE -PART N0.417368 AND 417369 <br /> 1 detector linkage assemblies are then clipped on later. BRACKET <br /> Each style of detector consists of two types of assemblies: / <br /> The Terminal Detector (Part No. 56838, 15375, or 417368) LINKAGE 0 f <br /> includes a test link and is placed last in a series of detectors. This <br /> Il detector is sometimes referred to as the end -of -line detector and <br /> is thus named because it is at the point at which the wire rope "ter- FUSIBLE U <br /> minates," or is anchored at the detector bracket. Only one terminal LINK <br /> detector is required per detection system. <br /> I 000159 <br /> The Series Detector (Part No. 56837, 15373, or 417369) is any FIGURE 21 <br /> detector located in -line between the regulated release assembly <br /> and the terminal detector. PULLEY ELBOWS <br /> I When using Part No. 56837 and 56838 style detectors, a total of There are two types of pulley elbows used to change the direction <br /> 12 detectors can be in one detection system: 11 series detectors, of the wire rope by 90 °. Ansul recommends for temperatures not in <br /> Part No. 56837 and 1 terminal detector, Part No. 56838. excess of 700 °F (371 °C). Part No. 415670 has socket ends with <br /> When using Part No. 15373 and 15375 style detectors, a total of 5 set screws for 1/2 in. conduit, and Part No. 423250 has compres- <br /> 1 detectors can be in one detection system: 4 series detectors, Part sion ring ends also for 1/2 in. conduit. Pulley elbows must be <br /> No. 15373 and 1 terminal detector, Part No. 15375. ordered in quantities of 50 as Shipping Assembly Part No. 415671 <br /> When using Part No. 417368 and 417369 style detectors, a total (socket end type) and Part No. 423251 (compression end type). <br /> of 15 detectors can be in one detection system: 14 series detec- No. 415670 PART NO. 423250 <br /> tors, Part No. 417369. and 1 terminal detector, Part No. 417368. , la 1111 O� <br /> I <br /> ' <br /> I (;) ® : _ All, <br /> 1 <br /> 1 000160 000161 <br /> FIGURE 22 <br /> • <br /> 1 <br /> 1 <br /> 1 <br />