Laserfiche WebLink
—�� Print Date: 3126/ <br /> w H �� <br /> F - Commercial <br /> , u'' Zephyrhills Fire Rescue <br /> L <br /> "' ' InspectionDate: 3/26/2009 3:00:OOPM <br /> :- _i 6907 Dairy Rd <br /> Zephyrhiils, 33542 InspectorName: Hector Noyas <br /> Phone: 813 - 780-0041 InspectionNumber: 1 -171 -09 -0602 <br /> Fax. 813 InspectionCause: Periodic <br /> Inspected Partv OccupancyType: Mercantile <br /> INSTA -CASH <br /> (000410) PropertyUseType: Specialty Shop <br /> 38050 15TH AVE ViolationCounts: 3 <br /> ZEPHYRHILLS, FL 33542 Hrs. 0.20 <br /> Ref. Number NFPA 30 (2008) 10.3 General Requirements. 10.3.5 General Requirements. <br /> Where utilized within a mercantile occupancy, the design, construction, and capacity of storage cabinets shall comply with the <br /> applicable provisions of Section 9.5. <br /> Ref. Number: NFPA 1 (2006) 10.19 Combustible Materials. 10.19.7 Fueled Equipment. <br /> Fueled equipment, including but not limited to motorcycles, mopeds, lawn -care equipment, and portable cooking equipment, <br /> shall not be stored, operated, or repaired within a building except under one of the following conditions: (1) The building or room <br /> has been constructed for such use in accordance with the building code. (2) The use is allowed by other provisions of this Code. <br /> Comment: All equipment that has fue lwtthin it must be removed from the building or the tanks must be purged of any flammable <br /> liquid. <br /> Notice: Correct Immediately <br /> Ref. Number: NFPA 1 (2006) 11. 1 Electrical Fire Safety. 11.1.2 Electrical Fire Safety. <br /> Al! electrical appliances, fixtures, equipment, or wiring shall be installed and maintained in accordance with NFPA 70, National <br /> Electrical Code. <br /> Comment: All wiring must be installed by a licensed Electricidn. Permits are also required. <br /> Comments: <br /> ,hange of ownership approved. Although, there are some Life and Fire Safety issues that are in need of attention to meet <br /> current Life Safety standards and Fire Code requirements. 1) Flammable liquid storage cannot continue to take place within the <br /> Building without proper safe guards. This may be in the form of creating a vented room with fire rated separation of at least 1 hour <br /> )r purge tanks before storing equipment within the building. 2) Install emergency lighting within the structure both East and West <br /> Malls.They must also be maintained 3) Change exit signs to battery back -up type as per Life Safety Code 101 4) Exposed romex <br /> miring within the structure must be replaced with wiring methods that meets NFPA 70. <br /> • <br /> Page 1 c <br />