Laserfiche WebLink
Limitations <br /> 1. The Solid & Vented Aluminum Soffit has been evaluated and meets the requirements of Section <br /> 2002.2 for use within the State of Florida excluding Section 2003 the "High Velocity Hurricane <br /> Zone ". <br /> 2. The Design Pressure Rating for the various size and spans are as follows: <br /> Design Pressure Ratings (PSF) <br /> Single Two Equal <br /> Material Roof Span Spans <br /> Overhang <br /> Pos. Neg. Pos. Neg. <br /> 12" 51.4 34.4 51.4 34.4 <br /> 3105 -H14/H16 16" 24.0 31.1 51.4 34.4 <br /> (0.013" Min. Thickness) 20" 14.3 18.8 51.4 34.4 <br /> 24" 9.5 12.6 39.5 34.4 <br /> 12" 51.4 34.4 51.4 34.4 <br /> 3105- H14 /H16 16" 32.6 34.4 51.4 34.4 <br /> (0.019" Min. Thickness) 20" 19.4 34.4 51.4 34.4 <br /> 24" 12.8 26.9 51.4 34.4 <br /> Wendell a y, P.E. <br /> FL o. 58 <br /> November 27, 2007 <br /> R: \A - Projects \Project Folders \proj 650 - 800 \pf786 \Documents \FL9980 New EVAL.doc <br /> Sheet 2 of 3 <br />